{"product_id":"gm-123428-aerco-boiler-and-water-heater-flame-detector-assembly-gf","title":"GM-123428  AERCO Boiler and Water Heater FLAME DETECTOR ASSEMBLY GF","description":"\u003ch1\u003eGM-123428 AERCO Boiler and Water Heater FLAME DETECTOR ASSEMBLY GF\u003c\/h1\u003e\n\u003cp\u003e\u003cspan style=\"background-color: rgb(255, 255, 0);\"\u003e\u003cb\u003e\u003cspan style=\"font-size: large; background-color: rgb(255, 255, 0);\"\u003eNormal Stocking Item in Our Warehouse \u003c\/span\u003e\u003c\/b\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cmeta content=\"text\/html; charset=us-ascii\" http-equiv=\"Content-Type\"\u003e\u003c\/p\u003e\n\u003cstyle\u003e\na {\n    text-decoration: none;\n    color: #464feb;\n}\ntr th, tr td {\n    border: 1px solid #e6e6e6;\n}\ntr th {\n    background-color: #f5f5f5;\n}\n\u003c\/style\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe \u003cstrong\u003eGM-123428 AERCO Flame Detector Assembly GF\u003c\/strong\u003e is a genuine OEM flame sensing assembly designed for use in compatible AERCO commercial boilers and water heaters. This critical combustion safety component continuously monitors burner flame presence and communicates directly with the ignition control system to verify safe burner operation. If flame is not detected or is lost during operation, the flame detector assembly helps initiate safety shutdown procedures to protect equipment and personnel.\u003c\/p\u003e\n\u003cp\u003eManufactured to AERCO factory specifications, the GM-123428 Flame Detector Assembly provides reliable flame verification, dependable combustion monitoring, and safe operation in demanding commercial heating and domestic hot water applications.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eCross-Reference\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eGM-123428\u003c\/li\u003e\n\u003cli\u003eGM123428\u003c\/li\u003e\n\u003cli\u003eAERCO GM-123428\u003c\/li\u003e\n\u003cli\u003eFlame Detector Assembly GF\u003c\/li\u003e\n\u003cli\u003eFlame Sensing Assembly\u003c\/li\u003e\n\u003cli\u003eBurner Flame Detector\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eDirect OEM\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eYes\u003c\/strong\u003e – Genuine AERCO OEM replacement flame detector assembly.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eCompatible Brands\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eAERCO\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompatible with select:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAERCO Commercial Boilers\u003c\/li\u003e\n\u003cli\u003eAERCO Commercial Water Heaters\u003c\/li\u003e\n\u003cli\u003eAERCO Benchmark Series Equipment\u003c\/li\u003e\n\u003cli\u003eAERCO High-Efficiency Heating Systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAlways verify compatibility using the equipment model and serial number.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eApplication\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eCommercial boilers\u003c\/li\u003e\n\u003cli\u003eCommercial water heaters\u003c\/li\u003e\n\u003cli\u003eBurner flame verification systems\u003c\/li\u003e\n\u003cli\u003eCombustion monitoring circuits\u003c\/li\u003e\n\u003cli\u003eIgnition safety controls\u003c\/li\u003e\n\u003cli\u003eOEM combustion system repairs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eRelated Components\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSpark Igniters\u003c\/li\u003e\n\u003cli\u003eIgnitor Injector Kits\u003c\/li\u003e\n\u003cli\u003eFlame Detector Replacement Kits\u003c\/li\u003e\n\u003cli\u003eFlame Rod Gaskets\u003c\/li\u003e\n\u003cli\u003eIgnition \/ Stepper Boards\u003c\/li\u003e\n\u003cli\u003eGas Pressure Switches\u003c\/li\u003e\n\u003cli\u003eCombustion Blowers\u003c\/li\u003e\n\u003cli\u003eAnnual Maintenance Kits\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnician Notes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eGenuine OEM AERCO flame sensing assembly.\u003c\/li\u003e\n\u003cli\u003eMonitors burner flame presence during operation.\u003c\/li\u003e\n\u003cli\u003eCritical safety device for proper combustion control.\u003c\/li\u003e\n\u003cli\u003eHelps prevent unsafe fuel operation conditions.\u003c\/li\u003e\n\u003cli\u003eInspect wiring, grounding, and mounting surfaces when replacing.\u003c\/li\u003e\n\u003cli\u003eVerify proper burner flame characteristics after installation.\u003c\/li\u003e\n\u003cli\u003eCheck ignition and combustion components when diagnosing flame detection faults.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eCommon Symptoms of Failure\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFlame failure fault codes\u003c\/li\u003e\n\u003cli\u003eBoiler ignition lockouts\u003c\/li\u003e\n\u003cli\u003eBurner shuts down after ignition\u003c\/li\u003e\n\u003cli\u003eRepeated ignition attempts\u003c\/li\u003e\n\u003cli\u003eIntermittent flame sensing\u003c\/li\u003e\n\u003cli\u003eNuisance shutdowns\u003c\/li\u003e\n\u003cli\u003eNo heat or hot water production\u003c\/li\u003e\n\u003cli\u003eCombustion safety faults\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eInstallation Tips\u003c\/h2\u003e\n\u003col\u003e\n\u003cli\u003eDisconnect electrical power before servicing.\u003c\/li\u003e\n\u003cli\u003eVerify replacement assembly compatibility.\u003c\/li\u003e\n\u003cli\u003eInspect flame detector wiring and connectors.\u003c\/li\u003e\n\u003cli\u003eClean burner surfaces if contamination is present.\u003c\/li\u003e\n\u003cli\u003eInstall the replacement assembly securely.\u003c\/li\u003e\n\u003cli\u003eVerify proper grounding and alignment.\u003c\/li\u003e\n\u003cli\u003eRestore power and test ignition operation.\u003c\/li\u003e\n\u003cli\u003eConfirm stable flame sensing through a complete firing cycle.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003chr\u003e\n\u003ch2\u003eRecommended Inspection Items\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSpark igniter condition\u003c\/li\u003e\n\u003cli\u003eBurner assembly cleanliness\u003c\/li\u003e\n\u003cli\u003eFlame rod gasket condition\u003c\/li\u003e\n\u003cli\u003eGas valve operation\u003c\/li\u003e\n\u003cli\u003eIgnition control board\u003c\/li\u003e\n\u003cli\u003eWiring harness connections\u003c\/li\u003e\n\u003cli\u003eGrounding integrity\u003c\/li\u003e\n\u003cli\u003eCombustion blower performance\u003c\/li\u003e\n\u003cli\u003eVenting system condition\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Neuco","offers":[{"title":"Default Title","offer_id":45558654926914,"sku":"GM-123428","price":626.82,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1071\/8320\/files\/Pic_large_e48c3815-5f0b-452e-a951-c2528000b69b.webp?v=1707621264","url":"https:\/\/hvacpartstoremarket.com\/products\/gm-123428-aerco-boiler-and-water-heater-flame-detector-assembly-gf","provider":"HVACpartstore","version":"1.0","type":"link"}