F92-0656 Copeland Comfort Control (White Rodgers) NATURAL GAS SPRING
F92-0656 Copeland Comfort Control (White Rodgers) NATURAL GAS SPRING
LP->Nat Gas Kit 36C,D,E,F,G Vlvs
The F92-0656 Copeland Comfort Control / White-Rodgers Natural Gas Conversion Spring is an OEM replacement conversion component designed for use in White-Rodgers 36C, 36D, 36E, 36F, and 36G series gas valves. This spring is used when converting compatible gas valves from LP (Propane) to Natural Gas, helping ensure proper regulator operation and gas pressure characteristics. Ideal for HVAC service technicians performing approved fuel conversions on furnaces, unit heaters, and other gas-fired equipment.
Cross-Reference
- White-Rodgers F92-0656
- Copeland Comfort Control F92-0656
- Emerson F92-0656
- LP to Natural Gas Conversion Spring
Direct OEM
- Copeland Comfort Control
- White-Rodgers
- Emerson
Compatible Brands
- White-Rodgers
- Emerson
- Coleman
- Evcon
- York
- Luxaire
- Fraser-Johnston
- Goodman
- Amana
- Rheem
- Ruud
- Carrier
- Bryant
- Payne
- Lennox
- Heil
- Tempstar
Application
- LP to Natural Gas conversions
- White-Rodgers 36C gas valves
- White-Rodgers 36D gas valves
- White-Rodgers 36E gas valves
- White-Rodgers 36F gas valves
- White-Rodgers 36G gas valves
- Furnace fuel conversions
- Gas-fired heating equipment service
Related Components
- Gas valve conversion kits
- Burner orifices
- Gas valves
- Pressure regulators
- Ignition controls
- Flame sensors
- Pilot assemblies
- Gas manifold components
- Limit switches
- Pressure switches
Technician Notes
- Intended for use with approved LP-to-Natural Gas conversion procedures.
- Compatible with select White-Rodgers 36-series gas valves.
- Proper spring installation is critical for maintaining correct manifold pressure.
- Gas pressure adjustments and combustion verification should be performed after conversion.
- Always follow appliance manufacturer conversion instructions.
- Fuel conversions should only be performed by qualified HVAC technicians.
Common Symptoms of Failure
- Improper manifold gas pressure
- Poor burner ignition
- Incomplete combustion
- Yellow burner flames
- Delayed ignition
- Burner rollout conditions
- Inconsistent heating performance
- Gas valve regulation issues
Installation Tips
- Shut off gas and electrical power before servicing.
- Verify valve model compatibility before installation.
- Follow appliance conversion procedures exactly.
- Replace associated conversion components when required.
- Adjust manifold gas pressure to manufacturer specifications.
- Leak test all gas connections after service.
- Verify proper combustion and burner flame characteristics.
Recommended Inspection Items
- Gas valve condition
- Manifold gas pressure
- Burner flame appearance
- Orifice sizing
- Heat exchanger condition
- Venting system operation
- Ignition performance
- Gas supply pressure
- Combustion quality
- Safety control operation