{"product_id":"b1370158-goodman-pressure-switch-70","title":"B1370158 Goodman pressure switch .70 AKA - 0130F00505S","description":"\u003ch1\u003eB1370158 Goodman pressure switch .70 AKA - 0130F00505S\u003c\/h1\u003e\n\u003cp\u003e\u003cmeta content=\"text\/html; charset=us-ascii\" http-equiv=\"Content-Type\"\u003e\u003c\/p\u003e\n\u003cstyle\u003e\na {\n    text-decoration: none;\n    color: #464feb;\n}\ntr th, tr td {\n    border: 1px solid #e6e6e6;\n}\ntr th {\n    background-color: #f5f5f5;\n}\n\u003c\/style\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe \u003cstrong\u003eB1370158 Goodman Pressure Switch\u003c\/strong\u003e is a genuine OEM furnace safety control designed for use in select Goodman, Amana, and Janitrol gas furnaces. Rated at \u003cstrong\u003e-0.70\" Water Column (WC)\u003c\/strong\u003e, this air pressure switch monitors inducer draft pressure and verifies proper venting conditions before allowing the ignition sequence to proceed. This model includes the \u003cstrong\u003emounting bracket\u003c\/strong\u003e and features a \u003cstrong\u003esingle hose nipple connection\u003c\/strong\u003e for pressure sensing.\u003c\/p\u003e\n\u003cp\u003eEngineered to Goodman factory specifications, the B1370158 helps ensure safe furnace operation by preventing burner ignition when proper combustion airflow or venting conditions are not present.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eCross-Reference\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eB1370158\u003c\/li\u003e\n\u003cli\u003eB13701-58\u003c\/li\u003e\n\u003cli\u003e0130F00505S\u003c\/li\u003e\n\u003cli\u003e9371VO-HS-0008\u003c\/li\u003e\n\u003cli\u003eGoodman Pressure Switch\u003c\/li\u003e\n\u003cli\u003e-0.70\" WC Pressure Switch\u003c\/li\u003e\n\u003cli\u003eAir Pressure Switch\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eDirect OEM\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eYes\u003c\/strong\u003e – Genuine Goodman OEM replacement pressure switch.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eCompatible Brands\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eGoodman\u003c\/li\u003e\n\u003cli\u003eAmana\u003c\/li\u003e\n\u003cli\u003eJanitrol\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eUsed in select models including:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eGSM060-3\u003c\/li\u003e\n\u003cli\u003eGMT090-4\u003c\/li\u003e\n\u003cli\u003eGMT115-5A\u003c\/li\u003e\n\u003cli\u003eGMS81155CXA\u003c\/li\u003e\n\u003cli\u003eGMS80905CNA\u003c\/li\u003e\n\u003cli\u003eGMS80905CXA\u003c\/li\u003e\n\u003cli\u003eGMS81155CNA\u003c\/li\u003e\n\u003cli\u003eGHS80905CNA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAlways verify compatibility using the furnace model and serial number.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cdiv class=\"___1dmoc29 f10pi13n ftgm304 f1enuhaj fdclmfp f1nbblvp fat0sn4 f1ov4xf1 fekwl8i f1lmfglv f1oz7aqm f1abmfm4 f1w619qj f16h0jq8\" role=\"group\" aria-label=\"Table content\"\u003e\n\u003ctable class=\"___h4t1f90 f1ddd56o f16vktn6 f1ahpp82 f11qra4b f1uinfot fibjyge fvueend f9yszdx f1fu4s3n f3l3pb3 f10ghnd0 f8fmt76 fjvbh62 f1qrqxae f1vw5qpk fc02sbz fxawf59 fymf513 f1aoyrul f1el8yx3 f1pymoxg f1ofu761 f1y24664 f7coize f1794535 f1o0pw0q fbjjl9v fk1v6el f16pyhcb f1ixlhx9 f12zef0i f8u40bk f1sdlqf5 ffufd3x fe1ov7n f1004tna fcoaxci fh0ee9u f15v23i2 f1660cg\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eB1370158\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlternate Part Number\u003c\/td\u003e\n\u003ctd\u003e0130F00505S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure Rating\u003c\/td\u003e\n\u003ctd\u003e-0.70\" WC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitch Type\u003c\/td\u003e\n\u003ctd\u003eFurnace Air Pressure Switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHose Connections\u003c\/td\u003e\n\u003ctd\u003e1 Nipple\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Bracket\u003c\/td\u003e\n\u003ctd\u003eIncluded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eDraft \/ Vent Verification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr\u003e\n\u003ch2\u003eApplication\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eGas furnaces\u003c\/li\u003e\n\u003cli\u003eInduced draft systems\u003c\/li\u003e\n\u003cli\u003eCombustion airflow proving\u003c\/li\u003e\n\u003cli\u003eFurnace vent monitoring\u003c\/li\u003e\n\u003cli\u003eIgnition safety circuits\u003c\/li\u003e\n\u003cli\u003eOEM furnace repairs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eRelated Components\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eDraft inducer motors\u003c\/li\u003e\n\u003cli\u003ePressure switch tubing\u003c\/li\u003e\n\u003cli\u003eFurnace control boards\u003c\/li\u003e\n\u003cli\u003eFlame sensors\u003c\/li\u003e\n\u003cli\u003eHot surface ignitors\u003c\/li\u003e\n\u003cli\u003eLimit switches\u003c\/li\u003e\n\u003cli\u003eVent assemblies\u003c\/li\u003e\n\u003cli\u003eCondensate drain systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnician Notes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eGenuine OEM Goodman pressure switch.\u003c\/li\u003e\n\u003cli\u003eRated at \u003cstrong\u003e-0.70\" WC\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eIncludes factory mounting bracket.\u003c\/li\u003e\n\u003cli\u003eSingle-port pressure sensing design.\u003c\/li\u003e\n\u003cli\u003eCritical safety device for ignition operation.\u003c\/li\u003e\n\u003cli\u003eAlways inspect pressure tubing and inducer performance before replacing the switch.\u003c\/li\u003e\n\u003cli\u003eVerify venting system is free of restrictions when diagnosing pressure switch faults.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eCommon Symptoms of Failure\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFurnace will not ignite\u003c\/li\u003e\n\u003cli\u003ePressure switch fault codes\u003c\/li\u003e\n\u003cli\u003eInducer motor runs but burners do not light\u003c\/li\u003e\n\u003cli\u003eIntermittent heating operation\u003c\/li\u003e\n\u003cli\u003eIgnition lockouts\u003c\/li\u003e\n\u003cli\u003eOpen pressure switch errors\u003c\/li\u003e\n\u003cli\u003eDraft proving failures\u003c\/li\u003e\n\u003cli\u003eHeating cycle interruptions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eInstallation Tips\u003c\/h2\u003e\n\u003col\u003e\n\u003cli\u003eDisconnect electrical power before servicing.\u003c\/li\u003e\n\u003cli\u003eVerify the replacement switch matches the original pressure rating.\u003c\/li\u003e\n\u003cli\u003eInspect pressure tubing for cracks, moisture, or obstructions.\u003c\/li\u003e\n\u003cli\u003eCheck inducer motor operation and venting condition.\u003c\/li\u003e\n\u003cli\u003eInstall the switch using the supplied mounting bracket.\u003c\/li\u003e\n\u003cli\u003eReconnect tubing securely.\u003c\/li\u003e\n\u003cli\u003eRestore power and test the heating cycle.\u003c\/li\u003e\n\u003cli\u003eVerify proper pressure switch operation through multiple starts.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003chr\u003e\n\u003ch2\u003eRecommended Inspection Items\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eDraft inducer assembly\u003c\/li\u003e\n\u003cli\u003ePressure switch tubing\u003c\/li\u003e\n\u003cli\u003eVent piping\u003c\/li\u003e\n\u003cli\u003eCondensate drain system\u003c\/li\u003e\n\u003cli\u003eFurnace control board\u003c\/li\u003e\n\u003cli\u003eFlame sensor\u003c\/li\u003e\n\u003cli\u003eIgnitor\u003c\/li\u003e\n\u003cli\u003eHeat exchanger condition\u003c\/li\u003e\n\u003cli\u003eIntake and exhaust terminations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cp\u003eGoodman air pressure switch. -0.70 PF (-0.70\" WC). Including mounting bracket. 1 hose nipple. Used on the following units: GSM060-3, GMT090-4, GMT115-5A, GMS81155CXA, GMS80905CNA, GMS80905CXA, GMS81155CNA \u0026amp; GHS80905CNA. Also known as part number B13701-58 \u0026amp; 9371VO-HS-0008.\u003c\/p\u003e","brand":"Quinn","offers":[{"title":"Default Title","offer_id":13061131523,"sku":"0130F00505S","price":55.11,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1071\/8320\/products\/yhst-130159302524877_2272_585425477.jpeg?v=1739539685","url":"https:\/\/hvacpartstoremarket.com\/products\/b1370158-goodman-pressure-switch-70","provider":"HVACpartstore","version":"1.0","type":"link"}