B1370158 Goodman pressure switch .70 AKA - 0130F00505S
B1370158 Goodman pressure switch .70 AKA - 0130F00505S
The B1370158 Goodman Pressure Switch is a genuine OEM furnace safety control designed for use in select Goodman, Amana, and Janitrol gas furnaces. Rated at -0.70" Water Column (WC), this air pressure switch monitors inducer draft pressure and verifies proper venting conditions before allowing the ignition sequence to proceed. This model includes the mounting bracket and features a single hose nipple connection for pressure sensing.
Engineered to Goodman factory specifications, the B1370158 helps ensure safe furnace operation by preventing burner ignition when proper combustion airflow or venting conditions are not present.
Cross-Reference
- B1370158
- B13701-58
- 0130F00505S
- 9371VO-HS-0008
- Goodman Pressure Switch
- -0.70" WC Pressure Switch
- Air Pressure Switch
Direct OEM
Yes – Genuine Goodman OEM replacement pressure switch.
Compatible Brands
- Goodman
- Amana
- Janitrol
Used in select models including:
- GSM060-3
- GMT090-4
- GMT115-5A
- GMS81155CXA
- GMS80905CNA
- GMS80905CXA
- GMS81155CNA
- GHS80905CNA
Always verify compatibility using the furnace model and serial number.
Specifications
| Specification | Value |
|---|---|
| Part Number | B1370158 |
| Alternate Part Number | 0130F00505S |
| Pressure Rating | -0.70" WC |
| Switch Type | Furnace Air Pressure Switch |
| Hose Connections | 1 Nipple |
| Mounting Bracket | Included |
| Application | Draft / Vent Verification |
Application
- Gas furnaces
- Induced draft systems
- Combustion airflow proving
- Furnace vent monitoring
- Ignition safety circuits
- OEM furnace repairs
Related Components
- Draft inducer motors
- Pressure switch tubing
- Furnace control boards
- Flame sensors
- Hot surface ignitors
- Limit switches
- Vent assemblies
- Condensate drain systems
Technician Notes
- Genuine OEM Goodman pressure switch.
- Rated at -0.70" WC.
- Includes factory mounting bracket.
- Single-port pressure sensing design.
- Critical safety device for ignition operation.
- Always inspect pressure tubing and inducer performance before replacing the switch.
- Verify venting system is free of restrictions when diagnosing pressure switch faults.
Common Symptoms of Failure
- Furnace will not ignite
- Pressure switch fault codes
- Inducer motor runs but burners do not light
- Intermittent heating operation
- Ignition lockouts
- Open pressure switch errors
- Draft proving failures
- Heating cycle interruptions
Installation Tips
- Disconnect electrical power before servicing.
- Verify the replacement switch matches the original pressure rating.
- Inspect pressure tubing for cracks, moisture, or obstructions.
- Check inducer motor operation and venting condition.
- Install the switch using the supplied mounting bracket.
- Reconnect tubing securely.
- Restore power and test the heating cycle.
- Verify proper pressure switch operation through multiple starts.
Recommended Inspection Items
- Draft inducer assembly
- Pressure switch tubing
- Vent piping
- Condensate drain system
- Furnace control board
- Flame sensor
- Ignitor
- Heat exchanger condition
- Intake and exhaust terminations
Goodman air pressure switch. -0.70 PF (-0.70" WC). Including mounting bracket. 1 hose nipple. Used on the following units: GSM060-3, GMT090-4, GMT115-5A, GMS81155CXA, GMS80905CNA, GMS80905CXA, GMS81155CNA & GHS80905CNA. Also known as part number B13701-58 & 9371VO-HS-0008.