{"product_id":"b1282628s-amana-goodman-gas-valve-24v-3-5-wc","title":"B1282628S Amana-Goodman GAS VALVE 24v 3.5\" WC","description":"\u003ch1\u003eB1282628S Amana-Goodman GAS VALVE 24v 3.5\" WC\u003c\/h1\u003e\n\u003cstyle\u003e\na {\n    text-decoration: none;\n    color: #464feb;\n}\ntr th, tr td {\n    border: 1px solid #e6e6e6;\n}\ntr th {\n    background-color: #f5f5f5;\n}\n\u003c\/style\u003e\n\u003cdiv\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eB1282628S Amana-Goodman Gas Valve\u003c\/strong\u003e is a genuine OEM \u003cstrong\u003e24-volt combination gas valve\u003c\/strong\u003e designed for use in select \u003cstrong\u003eAmana®\u003c\/strong\u003e and \u003cstrong\u003eGoodman®\u003c\/strong\u003e gas furnaces. Factory-calibrated for \u003cstrong\u003e3.5 inches water column (W.C.) manifold pressure\u003c\/strong\u003e, this valve provides precise gas flow control for dependable furnace ignition and heating performance. Engineered to meet original equipment specifications, the B1282628S ensures safe operation, reliable burner performance, and proper fuel delivery in residential forced-air heating systems.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eCross-Reference\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eB1282628S\u003c\/li\u003e\n\u003cli\u003eAmana B1282628S\u003c\/li\u003e\n\u003cli\u003eGoodman B1282628S\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cstyle\u003e\na {\n    text-decoration: none;\n    color: #464feb;\n}\ntr th, tr td {\n    border: 1px solid #e6e6e6;\n}\ntr th {\n    background-color: #f5f5f5;\n}\n\u003c\/style\u003e\n\u003cdiv\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cdiv\u003eWhite Rodgers 36G22Y-202\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eVerify furnace model, gas type, and valve configuration before ordering.\u003c\/em\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eDirect OEM\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eGoodman\u003c\/li\u003e\n\u003cli\u003eAmana\u003c\/li\u003e\n\u003cli\u003eDaikin Comfort Technologies\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eCompatible Brands\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eGoodman\u003c\/li\u003e\n\u003cli\u003eAmana\u003c\/li\u003e\n\u003cli\u003eJanitrol\u003c\/li\u003e\n\u003cli\u003eGMP Series Furnaces\u003c\/li\u003e\n\u003cli\u003eSelect Daikin residential gas furnace models\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eAlways confirm compatibility using the furnace model and serial number.\u003c\/em\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eApplication\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eResidential gas furnaces\u003c\/li\u003e\n\u003cli\u003eForced-air heating systems\u003c\/li\u003e\n\u003cli\u003eElectronic ignition systems\u003c\/li\u003e\n\u003cli\u003eNatural gas heating equipment\u003c\/li\u003e\n\u003cli\u003eGoodman and Amana furnace replacements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eRelated Components\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eHot Surface Ignitors\u003c\/li\u003e\n\u003cli\u003eFlame Sensors\u003c\/li\u003e\n\u003cli\u003eFurnace Control Boards\u003c\/li\u003e\n\u003cli\u003ePressure Switches\u003c\/li\u003e\n\u003cli\u003eLimit Switches\u003c\/li\u003e\n\u003cli\u003eDraft Inducer Motors\u003c\/li\u003e\n\u003cli\u003eGas Manifold Assemblies\u003c\/li\u003e\n\u003cli\u003eThermostats\u003c\/li\u003e\n\u003cli\u003eBurner Assemblies\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnician Notes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eGenuine OEM Goodman\/Amana replacement.\u003c\/li\u003e\n\u003cli\u003e24 VAC operation.\u003c\/li\u003e\n\u003cli\u003eFactory manifold pressure rated at \u003cstrong\u003e3.5\" W.C.\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eDesigned for electronic ignition furnace systems.\u003c\/li\u003e\n\u003cli\u003eVerify gas pressure and combustion performance after installation.\u003c\/li\u003e\n\u003cli\u003eAlways leak-test gas connections following replacement.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eCommon Symptoms of Failure\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFurnace will not ignite\u003c\/li\u003e\n\u003cli\u003eNo gas flow to burners\u003c\/li\u003e\n\u003cli\u003eIntermittent heating operation\u003c\/li\u003e\n\u003cli\u003eDelayed ignition\u003c\/li\u003e\n\u003cli\u003eBurner dropout during operation\u003c\/li\u003e\n\u003cli\u003eIgnition lockout faults\u003c\/li\u003e\n\u003cli\u003eInsufficient heating output\u003c\/li\u003e\n\u003cli\u003eGas valve fails to energize\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eInstallation Tips\u003c\/h2\u003e\n\u003col\u003e\n\u003cli\u003eDisconnect electrical power and shut off gas supply.\u003c\/li\u003e\n\u003cli\u003eVerify replacement part number before installation.\u003c\/li\u003e\n\u003cli\u003eTransfer fittings as required using approved gas-rated sealant.\u003c\/li\u003e\n\u003cli\u003eInstall valve in the correct flow direction.\u003c\/li\u003e\n\u003cli\u003eLeak-test all connections after installation.\u003c\/li\u003e\n\u003cli\u003eVerify manifold pressure is 3.5\" W.C. or per furnace specifications.\u003c\/li\u003e\n\u003cli\u003eCheck ignition sequence and burner operation.\u003c\/li\u003e\n\u003cli\u003ePerform final combustion and safety checks.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003chr\u003e\n\u003ch2\u003eRecommended Inspection Items\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eHot surface ignitor condition\u003c\/li\u003e\n\u003cli\u003eFlame sensor cleanliness\u003c\/li\u003e\n\u003cli\u003eBurner assembly condition\u003c\/li\u003e\n\u003cli\u003eGas supply pressure\u003c\/li\u003e\n\u003cli\u003eHeat exchanger condition\u003c\/li\u003e\n\u003cli\u003ePressure switch operation\u003c\/li\u003e\n\u003cli\u003eVenting system integrity\u003c\/li\u003e\n\u003cli\u003eFurnace control board diagnostics\u003c\/li\u003e\n\u003cli\u003eAir filter condition\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Quinn","offers":[{"title":"Default Title","offer_id":45561218564162,"sku":"b1282628s","price":136.75,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1071\/8320\/products\/th_100_654c1ec3-221b-4cfe-b89c-022ea400d650.jpg?v=1739523260","url":"https:\/\/hvacpartstoremarket.com\/products\/b1282628s-amana-goodman-gas-valve-24v-3-5-wc","provider":"HVACpartstore","version":"1.0","type":"link"}