colemanhvacparts.com, www.darindevries.com

B1282628S Amana-Goodman GAS VALVE 24v 3.5" WC

  • $ 136.75
    Unit price per 
  • Save $ 18.87
Shipping calculated at checkout.


B1282628S Amana-Goodman GAS VALVE 24v 3.5" WC

 

The B1282628S Amana-Goodman Gas Valve is a genuine OEM 24-volt combination gas valve designed for use in select Amana® and Goodman® gas furnaces. Factory-calibrated for 3.5 inches water column (W.C.) manifold pressure, this valve provides precise gas flow control for dependable furnace ignition and heating performance. Engineered to meet original equipment specifications, the B1282628S ensures safe operation, reliable burner performance, and proper fuel delivery in residential forced-air heating systems.


Cross-Reference

  • B1282628S
  • Amana B1282628S
  • Goodman B1282628S
  • White Rodgers 36G22Y-202

Verify furnace model, gas type, and valve configuration before ordering.


Direct OEM

  • Goodman
  • Amana
  • Daikin Comfort Technologies

Compatible Brands

  • Goodman
  • Amana
  • Janitrol
  • GMP Series Furnaces
  • Select Daikin residential gas furnace models

Always confirm compatibility using the furnace model and serial number.


Application

  • Residential gas furnaces
  • Forced-air heating systems
  • Electronic ignition systems
  • Natural gas heating equipment
  • Goodman and Amana furnace replacements

Related Components

  • Hot Surface Ignitors
  • Flame Sensors
  • Furnace Control Boards
  • Pressure Switches
  • Limit Switches
  • Draft Inducer Motors
  • Gas Manifold Assemblies
  • Thermostats
  • Burner Assemblies

Technician Notes

  • Genuine OEM Goodman/Amana replacement.
  • 24 VAC operation.
  • Factory manifold pressure rated at 3.5" W.C.
  • Designed for electronic ignition furnace systems.
  • Verify gas pressure and combustion performance after installation.
  • Always leak-test gas connections following replacement.

Common Symptoms of Failure

  • Furnace will not ignite
  • No gas flow to burners
  • Intermittent heating operation
  • Delayed ignition
  • Burner dropout during operation
  • Ignition lockout faults
  • Insufficient heating output
  • Gas valve fails to energize

Installation Tips

  1. Disconnect electrical power and shut off gas supply.
  2. Verify replacement part number before installation.
  3. Transfer fittings as required using approved gas-rated sealant.
  4. Install valve in the correct flow direction.
  5. Leak-test all connections after installation.
  6. Verify manifold pressure is 3.5" W.C. or per furnace specifications.
  7. Check ignition sequence and burner operation.
  8. Perform final combustion and safety checks.

Recommended Inspection Items

  • Hot surface ignitor condition
  • Flame sensor cleanliness
  • Burner assembly condition
  • Gas supply pressure
  • Heat exchanger condition
  • Pressure switch operation
  • Venting system integrity
  • Furnace control board diagnostics
  • Air filter condition

We Also Recommend