{"product_id":"b1256558-goodman-5kw-1-pole-sequencer-h10-20-c30-70","title":"B1256558 Goodman 5KW 1-pole sequencer H10-20 C30-70","description":"\u003ch1\u003eB1256558 Goodman 5KW 1-pole sequencer H10-20 C30-70.\u003c\/h1\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"background-color: rgb(255, 255, 0);\"\u003eIN STOCK\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2\u003eSequencer with one switch. 10-20 seconds on (H10-20), 30-70 (C30-70) seconds off. Bottom terminals are 24V.\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eOEM?grade 1?pole heat sequencer used in Goodman electric furnace and air?handler heat kits. Controls staged energizing and de?energizing of heating elements to prevent inrush load and ensure smooth operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch3\u003e?? Technical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSwitches:\u003c\/strong\u003e 1 pole\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eON Timing (H10?20):\u003c\/strong\u003e 10–20 seconds\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOFF Timing (C30?70):\u003c\/strong\u003e 30–70 seconds\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eControl Voltage:\u003c\/strong\u003e 24V (bottom terminals)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e 5 kW electric heat kits and compatible Goodman air handlers\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e Standard 2?hole bracket\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eElectrical Rating:\u003c\/strong\u003e Designed for resistive heat sequencing loads\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch3\u003e?? Function \u0026amp; Operation\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eStages heating element activation to reduce electrical surge.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eProvides timed delay between blower operation and heat strip energizing.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eEnsures proper cool?down cycle by delaying heat strip shutoff.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHelps maintain safe, stable temperature rise inside the air handler.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch3\u003e?? Compatibility\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eCommonly used in Goodman, Amana, and Janitrol electric heat kits requiring a \u003cstrong\u003esingle?pole sequencer\u003c\/strong\u003e with \u003cstrong\u003eH10?20 \/ C30?70\u003c\/strong\u003e timing. (If you want, I can generate a compatibility block by model number for your listing template.)\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch3\u003e?? What’s Included\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e1 × OEM?spec 1?pole sequencer\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePre?installed mounting bracket\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch3\u003e? Ideal Replacement For\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFailed or sticking sequencers\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eUnits with delayed or non?responsive heat strip activation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOverheating issues caused by improper staging\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eClick to watch how a sequencer works ----\u0026gt; \u003ca href=\"https:\/\/youtu.be\/5YjL8eR5VJ0\"\u003ehttps:\/\/youtu.be\/5YjL8eR5VJ0\u003c\/a\u003e\n\u003c\/h2\u003e\n\u003cp\u003eUsed on the following 5,000KW units: AE24-05, AE30-05, HKR, HW18-05 \u0026amp; AE24-05 and others.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eAlso known as part number or replaces L39-276, 309561, BT1256500, B126551, B12565-58 \u0026amp; B12565-51. The timings on the old sequencer that this one replaces were H10-20 and C30-70.\u003c\/p\u003e","brand":"Quinn","offers":[{"title":"Default Title","offer_id":13061132739,"sku":"B1256558","price":27.79,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1071\/8320\/products\/b1256558-goodman-5kw-1-pole-sequencer-h10-20-c30-70-1.jpeg?v=1566073326","url":"https:\/\/hvacpartstoremarket.com\/products\/b1256558-goodman-5kw-1-pole-sequencer-h10-20-c30-70","provider":"HVACpartstore","version":"1.0","type":"link"}