9722 Regal Rexnord - Century Motors Condenser Fan Motor 208-230V, 1075 RPM
9722 Regal Rexnord - Century Motors Condenser Fan Motor 208-230V, 1075 RPM
1/8-1/10-1/12HP, 208-230 Vac, Single Phase, 1075 RPM, 1 Speed, .9-.6-.5 Amps, 42 Nema Frame Size, Enclosed, Ball Bearing, 1/2" x 3" Shaft, Reversible Rotation, Permanent Split Capacitor Motor
Replaces S1-024-26067-010
The 9722 Regal Rexnord Century Condenser Fan Motor is a premium replacement condenser fan motor designed for residential and light commercial air conditioning and heat pump systems. Rated at 208-230 Volts, 1075 RPM, and featuring a multi-horsepower design of 1/8, 1/10, and 1/12 HP, this versatile motor delivers dependable condenser airflow for efficient heat rejection and reliable cooling system performance.
Built with a durable 42 Frame, permanent split capacitor (PSC) motor design, ball bearings, and reversible rotation, the 9722 motor is engineered for long service life and dependable operation in demanding outdoor HVAC applications. This motor serves as a direct replacement for Source 1 S1-024-26067-010 and related condenser fan motor applications.
Cross-Reference
- 9722
- Regal Rexnord 9722
- Century 9722
- S1-024-26067-010
- S102426067010
- Condenser Fan Motor
- PSC Condenser Motor
Direct Replacement
Replaces:
- S1-024-26067-010
Compatible Brands
- York
- Coleman
- Luxaire
- Fraser-Johnston
- Source 1 Applications
- Other compatible OEM condenser units
Always verify motor specifications, shaft dimensions, rotation, and capacitor requirements before ordering.
Product Specifications
| Specification | Value |
|---|---|
| Voltage | 208-230 VAC |
| Horsepower | 1/8 - 1/10 - 1/12 HP |
| Speed | 1075 RPM |
| Phase | Single Phase |
| Amperage | 0.9 / 0.6 / 0.5 A |
| Speeds | 1 |
| Frame Size | 42 NEMA |
| Motor Type | PSC (Permanent Split Capacitor) |
| Bearings | Ball Bearing |
| Enclosure | Totally Enclosed |
| Shaft Size | 1/2" x 3" |
| Rotation | Reversible |
| Frequency | 60 Hz |
Application
- Air conditioning condensers
- Heat pumps
- Outdoor condensing units
- Condenser fan assemblies
- Residential HVAC systems
- Commercial HVAC applications
Related Components
- Fan blades
- Motor mounting brackets
- Run capacitors
- Condenser contactors
- Defrost controls
- Condenser coils
- Fan guards
- Outdoor unit control boards
Technician Notes
- Genuine Regal Rexnord Century replacement motor.
- Reversible rotation for flexible installation.
- Ball bearing construction for long life and quiet performance.
- PSC motor design for dependable efficiency.
- Verify proper capacitor size before startup.
- Match motor speed and horsepower requirements to the original application.
- Inspect fan blade balance and condenser coil cleanliness during replacement.
Common Symptoms of Failure
- Outdoor fan will not start
- Condenser motor overheating
- Slow fan operation
- Excessive motor noise
- Bearing failure
- Condenser high-pressure trips
- Reduced cooling performance
- Fan motor seizing
Installation Tips
- Disconnect electrical power before servicing.
- Verify replacement motor specifications match the original motor.
- Inspect the fan blade for wear or imbalance.
- Replace the run capacitor if recommended.
- Verify proper motor rotation before final assembly.
- Secure all wiring connections.
- Check motor amperage after startup.
- Confirm proper condenser airflow and system operation.
Recommended Inspection Items
- Run capacitor condition
- Fan blade balance
- Condenser coil cleanliness
- Contactors
- Electrical connections
- Defrost controls
- Refrigerant operating pressures
- Fan guard condition
- Outdoor unit vibration