{"product_id":"95251246-aerco-boiler-flame-detector","title":"95251246 AERCO Boiler FLAME DETECTOR","description":"\u003ch1\u003e95251246 AERCO Boiler FLAME DETECTOR\u003c\/h1\u003e\n\u003cp\u003e\u003cb\u003e\u003cspan style=\"font-size: large;\"\u003e\u003cspan style=\"background-color: rgb(255, 255, 0);\"\u003eNormal Stocking Item in Our Warehouse \u003c\/span\u003e\u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cmeta content=\"text\/html; charset=us-ascii\" http-equiv=\"Content-Type\"\u003e\u003c\/p\u003e\n\u003cstyle\u003e\na {\n    text-decoration: none;\n    color: #464feb;\n}\ntr th, tr td {\n    border: 1px solid #e6e6e6;\n}\ntr th {\n    background-color: #f5f5f5;\n}\n\u003c\/style\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe \u003cstrong\u003e95251246 AERCO Flame Detector\u003c\/strong\u003e is a genuine OEM flame-sensing device designed for use in compatible AERCO commercial boilers. This critical safety component continuously monitors burner flame presence and provides verification signals to the boiler control system during operation. If a flame is not detected or is lost during a heating cycle, the flame detector helps initiate safety shutdown procedures to prevent unsafe operating conditions.\u003c\/p\u003e\n\u003cp\u003eEngineered to AERCO factory specifications, the 95251246 Flame Detector helps ensure reliable burner operation, proper combustion monitoring, and safe system performance in commercial heating applications.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eCross-Reference\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e95251246\u003c\/li\u003e\n\u003cli\u003eAERCO 95251246\u003c\/li\u003e\n\u003cli\u003eFlame Detector\u003c\/li\u003e\n\u003cli\u003eFlame Sensor\u003c\/li\u003e\n\u003cli\u003eBoiler Flame Detection Sensor\u003c\/li\u003e\n\u003cli\u003eBurner Flame Sensor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eDirect OEM\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eYes\u003c\/strong\u003e – Genuine AERCO OEM replacement flame detector.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eCompatible Brands\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eAERCO\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompatible with select:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAERCO Commercial Boilers\u003c\/li\u003e\n\u003cli\u003eAERCO High-Efficiency Boilers\u003c\/li\u003e\n\u003cli\u003eAERCO Commercial Heating Equipment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAlways verify compatibility using the equipment model and serial number.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eApplication\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eCommercial boiler flame monitoring\u003c\/li\u003e\n\u003cli\u003eBurner safety systems\u003c\/li\u003e\n\u003cli\u003eCombustion verification circuits\u003c\/li\u003e\n\u003cli\u003eIgnition safety controls\u003c\/li\u003e\n\u003cli\u003eOEM boiler repairs\u003c\/li\u003e\n\u003cli\u003eHeating system safety monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eRelated Components\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSpark Igniters\u003c\/li\u003e\n\u003cli\u003eIgnitor Injector Kits\u003c\/li\u003e\n\u003cli\u003eIgnition \/ Stepper Boards\u003c\/li\u003e\n\u003cli\u003eGas Valves\u003c\/li\u003e\n\u003cli\u003eBurner Assemblies\u003c\/li\u003e\n\u003cli\u003eLimit Controls\u003c\/li\u003e\n\u003cli\u003eExhaust Temperature Sensors\u003c\/li\u003e\n\u003cli\u003eWater Outlet Temperature Sensors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnician Notes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eGenuine OEM flame detection component.\u003c\/li\u003e\n\u003cli\u003eConfirms burner flame presence during operation.\u003c\/li\u003e\n\u003cli\u003eCritical safety device for proper boiler operation.\u003c\/li\u003e\n\u003cli\u003eFlame-sensing issues may be caused by wiring faults, poor grounding, burner contamination, or ignition problems.\u003c\/li\u003e\n\u003cli\u003eInspect ignition and combustion components when replacing the flame detector.\u003c\/li\u003e\n\u003cli\u003eVerify grounding and burner flame characteristics during startup.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eCommon Symptoms of Failure\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eBoiler ignition lockout\u003c\/li\u003e\n\u003cli\u003eFlame failure fault codes\u003c\/li\u003e\n\u003cli\u003eBurner shuts down after ignition\u003c\/li\u003e\n\u003cli\u003eIntermittent flame sensing\u003c\/li\u003e\n\u003cli\u003eRepeated ignition attempts\u003c\/li\u003e\n\u003cli\u003eNuisance safety shutdowns\u003c\/li\u003e\n\u003cli\u003eNo heat condition\u003c\/li\u003e\n\u003cli\u003eUnreliable burner operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eInstallation Tips\u003c\/h2\u003e\n\u003col\u003e\n\u003cli\u003eDisconnect power before servicing.\u003c\/li\u003e\n\u003cli\u003eVerify replacement part number compatibility.\u003c\/li\u003e\n\u003cli\u003eInspect flame detector wiring and connections.\u003c\/li\u003e\n\u003cli\u003eClean burner surfaces if contamination is present.\u003c\/li\u003e\n\u003cli\u003eInstall the sensor in the correct factory location.\u003c\/li\u003e\n\u003cli\u003eVerify proper grounding of the burner assembly.\u003c\/li\u003e\n\u003cli\u003eRestore power and test the ignition sequence.\u003c\/li\u003e\n\u003cli\u003eConfirm stable flame sensing during operation.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003chr\u003e\n\u003ch2\u003eRecommended Inspection Items\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSpark igniter condition\u003c\/li\u003e\n\u003cli\u003eBurner assembly cleanliness\u003c\/li\u003e\n\u003cli\u003eGas valve operation\u003c\/li\u003e\n\u003cli\u003eIgnition control board\u003c\/li\u003e\n\u003cli\u003eWiring harness connections\u003c\/li\u003e\n\u003cli\u003eGrounding integrity\u003c\/li\u003e\n\u003cli\u003eCombustion performance\u003c\/li\u003e\n\u003cli\u003eVenting system condition\u003c\/li\u003e\n\u003cli\u003eControl system diagnostics\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Neuco","offers":[{"title":"Default Title","offer_id":45558655320130,"sku":"95251246","price":157.04,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1071\/8320\/files\/Pic_large_ab4a40b1-6d9c-49d8-944f-6e0c113d9ef2.webp?v=1739516657","url":"https:\/\/hvacpartstoremarket.com\/products\/95251246-aerco-boiler-flame-detector","provider":"HVACpartstore","version":"1.0","type":"link"}