95251246 AERCO Boiler FLAME DETECTOR
95251246 AERCO Boiler FLAME DETECTOR
Normal Stocking Item in Our Warehouse
The 95251246 AERCO Flame Detector is a genuine OEM flame-sensing device designed for use in compatible AERCO commercial boilers. This critical safety component continuously monitors burner flame presence and provides verification signals to the boiler control system during operation. If a flame is not detected or is lost during a heating cycle, the flame detector helps initiate safety shutdown procedures to prevent unsafe operating conditions.
Engineered to AERCO factory specifications, the 95251246 Flame Detector helps ensure reliable burner operation, proper combustion monitoring, and safe system performance in commercial heating applications.
Cross-Reference
- 95251246
- AERCO 95251246
- Flame Detector
- Flame Sensor
- Boiler Flame Detection Sensor
- Burner Flame Sensor
Direct OEM
Yes – Genuine AERCO OEM replacement flame detector.
Compatible Brands
- AERCO
Compatible with select:
- AERCO Commercial Boilers
- AERCO High-Efficiency Boilers
- AERCO Commercial Heating Equipment
Always verify compatibility using the equipment model and serial number.
Application
- Commercial boiler flame monitoring
- Burner safety systems
- Combustion verification circuits
- Ignition safety controls
- OEM boiler repairs
- Heating system safety monitoring
Related Components
- Spark Igniters
- Ignitor Injector Kits
- Ignition / Stepper Boards
- Gas Valves
- Burner Assemblies
- Limit Controls
- Exhaust Temperature Sensors
- Water Outlet Temperature Sensors
Technician Notes
- Genuine OEM flame detection component.
- Confirms burner flame presence during operation.
- Critical safety device for proper boiler operation.
- Flame-sensing issues may be caused by wiring faults, poor grounding, burner contamination, or ignition problems.
- Inspect ignition and combustion components when replacing the flame detector.
- Verify grounding and burner flame characteristics during startup.
Common Symptoms of Failure
- Boiler ignition lockout
- Flame failure fault codes
- Burner shuts down after ignition
- Intermittent flame sensing
- Repeated ignition attempts
- Nuisance safety shutdowns
- No heat condition
- Unreliable burner operation
Installation Tips
- Disconnect power before servicing.
- Verify replacement part number compatibility.
- Inspect flame detector wiring and connections.
- Clean burner surfaces if contamination is present.
- Install the sensor in the correct factory location.
- Verify proper grounding of the burner assembly.
- Restore power and test the ignition sequence.
- Confirm stable flame sensing during operation.
Recommended Inspection Items
- Spark igniter condition
- Burner assembly cleanliness
- Gas valve operation
- Ignition control board
- Wiring harness connections
- Grounding integrity
- Combustion performance
- Venting system condition
- Control system diagnostics