{"product_id":"903906-nordyne-15kw-240v-top-element-assembly","title":"903906 Nordyne 15kw@240v TOP ELEMENT ASSEMBLY","description":"\u003ch1\u003e903906 Nordyne 15kw@240v TOP ELEMENT ASSEMBLY\u003c\/h1\u003e\n\u003cstyle\u003e\na {\n    text-decoration: none;\n    color: #464feb;\n}\ntr th, tr td {\n    border: 1px solid #e6e6e6;\n}\ntr th {\n    background-color: #f5f5f5;\n}\n\u003c\/style\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe \u003cstrong\u003e903906 Heating Element Assembly\u003c\/strong\u003e is a replacement \u003cstrong\u003e15 kW electric furnace heating element\u003c\/strong\u003e designed for select Nordyne, Intertherm, and Miller electric furnaces. Identified as \u003cstrong\u003eAssembly Number 270004\u003c\/strong\u003e, this heater assembly delivers full electric heat output for reliable furnace performance and efficient operation during peak heating demands. The assembly features a \u003cstrong\u003e9.25\" x 3.0\" mounting plate\u003c\/strong\u003e, \u003cstrong\u003e11.25-inch element depth\u003c\/strong\u003e, and includes an adjustable support rod that can be trimmed to fit specific applications. The compatible \u003cstrong\u003e\u003ca href=\"https:\/\/hvacpartstoremarket.com\/products\/626513r-nordyne-limit-switch-l200-50f-for-electric-heating-element-lim?_pos=1\u0026amp;_sid=63d1e9b58\u0026amp;_ss=r\"\u003e626513R\u003c\/a\u003e L200-50F \u003cspan style=\"background-color: rgb(255, 255, 0);\"\u003elimit switch\u003c\/span\u003e\u003c\/strong\u003e\u003cspan style=\"background-color: rgb(255, 255, 0);\"\u003e is sold separately\u003c\/span\u003e and is not included with the assembly.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eCross‑Reference\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e903906\u003c\/li\u003e\n\u003cli\u003e270004\u003c\/li\u003e\n\u003cli\u003eNordyne 903906\u003c\/li\u003e\n\u003cli\u003eIntertherm 903906\u003c\/li\u003e\n\u003cli\u003eMiller 903906\u003c\/li\u003e\n\u003cli\u003eHeating Element Assembly 270004\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eDirect OEM\u003c\/h2\u003e\n\u003cp\u003eDirect replacement heating element assembly for Nordyne-style electric furnace applications.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eCompatible Brands\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eNordyne\u003c\/li\u003e\n\u003cli\u003eIntertherm\u003c\/li\u003e\n\u003cli\u003eMiller\u003c\/li\u003e\n\u003cli\u003eFrigidaire\u003c\/li\u003e\n\u003cli\u003eGibson\u003c\/li\u003e\n\u003cli\u003eMaytag\u003c\/li\u003e\n\u003cli\u003eTappan\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eVerify model and serial number compatibility before ordering.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eApplication\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eElectric Furnaces\u003c\/li\u003e\n\u003cli\u003eElectric Heater Assemblies\u003c\/li\u003e\n\u003cli\u003eResidential Electric Heating Systems\u003c\/li\u003e\n\u003cli\u003eReplacement Heat Strip Assemblies\u003c\/li\u003e\n\u003cli\u003eMulti-Stage Electric Furnace Applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHeating Capacity: \u003cstrong\u003e15 kW @ 240 Volts\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eAssembly Number: \u003cstrong\u003e270004\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eMounting Plate Size: \u003cstrong\u003e9.25\" x 3.0\"\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eElement Depth: \u003cstrong\u003e11.25\"\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eAdjustable Support Rod Included\u003c\/li\u003e\n\u003cli\u003eLimit Switch Not Included\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eRelated Components\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e626513R Limit Switch\u003c\/li\u003e\n\u003cli\u003eElectric Heat Sequencers\u003c\/li\u003e\n\u003cli\u003eBlower Motors\u003c\/li\u003e\n\u003cli\u003eFan Relays\u003c\/li\u003e\n\u003cli\u003eControl Boards\u003c\/li\u003e\n\u003cli\u003eHeater Racks\u003c\/li\u003e\n\u003cli\u003eTerminal Blocks\u003c\/li\u003e\n\u003cli\u003eWiring Harnesses\u003c\/li\u003e\n\u003cli\u003eContactor Assemblies\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnician Notes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned as a complete heater assembly replacement.\u003c\/li\u003e\n\u003cli\u003eInspect limit switches whenever replacing heat strips.\u003c\/li\u003e\n\u003cli\u003eThe support rod may be trimmed for proper installation.\u003c\/li\u003e\n\u003cli\u003eVerify all electrical connections are tight before energizing.\u003c\/li\u003e\n\u003cli\u003eCheck operating amperage after installation.\u003c\/li\u003e\n\u003cli\u003eThe \u003cstrong\u003e\u003ca href=\"https:\/\/hvacpartstoremarket.com\/products\/626513r-nordyne-limit-switch-l200-50f-for-electric-heating-element-lim?_pos=1\u0026amp;_sid=63d1e9b58\u0026amp;_ss=r\"\u003e626513R\u003c\/a\u003e L200-50F limit switch\u003c\/strong\u003e commonly used with this assembly is sold separately.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eCommon Symptoms of Failure\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eNo electric heat\u003c\/li\u003e\n\u003cli\u003ePartial heating output\u003c\/li\u003e\n\u003cli\u003eOpen heating elements\u003c\/li\u003e\n\u003cli\u003eBurned or broken heat strips\u003c\/li\u003e\n\u003cli\u003eFrequent limit trips\u003c\/li\u003e\n\u003cli\u003eFurnace blower operates without heat\u003c\/li\u003e\n\u003cli\u003eUneven heat staging\u003c\/li\u003e\n\u003cli\u003eHigh electrical consumption with poor heating performance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eInstallation Tips\u003c\/h2\u003e\n\u003col\u003e\n\u003cli\u003eDisconnect all electrical power to the furnace.\u003c\/li\u003e\n\u003cli\u003eVerify heater assembly specifications before installation.\u003c\/li\u003e\n\u003cli\u003eLabel and inspect all wiring connections.\u003c\/li\u003e\n\u003cli\u003eRemove the existing heater assembly.\u003c\/li\u003e\n\u003cli\u003eInstall the replacement assembly securely.\u003c\/li\u003e\n\u003cli\u003eTrim support rod as required.\u003c\/li\u003e\n\u003cli\u003eInspect or replace the limit switch if needed.\u003c\/li\u003e\n\u003cli\u003eRestore power and verify proper operation.\u003c\/li\u003e\n\u003cli\u003eConfirm current draw and heat staging after startup.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003chr\u003e\n\u003ch2\u003eRecommended Inspection Items\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/hvacpartstoremarket.com\/products\/626513r-nordyne-limit-switch-l200-50f-for-electric-heating-element-lim?_pos=1\u0026amp;_sid=63d1e9b58\u0026amp;_ss=r\"\u003e626513R\u003c\/a\u003e Limit Switch\u003c\/li\u003e\n\u003cli\u003eHeater Sequencers\u003c\/li\u003e\n\u003cli\u003eBlower Motor\u003c\/li\u003e\n\u003cli\u003eBlower Wheel\u003c\/li\u003e\n\u003cli\u003eElectrical Connections\u003c\/li\u003e\n\u003cli\u003eTerminal Blocks\u003c\/li\u003e\n\u003cli\u003eWire Insulation\u003c\/li\u003e\n\u003cli\u003eControl Board\u003c\/li\u003e\n\u003cli\u003eContactors\u003c\/li\u003e\n\u003cli\u003eSupply Air Temperature Rise\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch2\u003e15 kw heating element. Assembly number 270004. Front plate measures 9.25\" x 3.0\". 11.25\" deep plus rod which can be trimmed to fit. Limit switch \u003ca href=\"https:\/\/hvacpartstoremarket.com\/products\/626513r-nordyne-limit-switch-l200-50f-for-electric-heating-element-lim?_pos=1\u0026amp;_sid=63d1e9b58\u0026amp;_ss=r\" target=\"_blank\" rel=\"noopener\"\u003e626513R\u003c\/a\u003e\u003ca href=\"https:\/\/colemanhvacparts.com\/products\/l200-50f-nordyne-limit-switch-626513r?_pos=1\u0026amp;_sid=ed88658b6\u0026amp;_ss=r\" rel=\"noopener\" target=\"_blank\"\u003e\u003c\/a\u003e not included.\u003c\/h2\u003e","brand":"Quinn","offers":[{"title":"Default Title","offer_id":40298066772034,"sku":"903906","price":337.24,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1071\/8320\/files\/903906-3.jpg?v=1739507464","url":"https:\/\/hvacpartstoremarket.com\/products\/903906-nordyne-15kw-240v-top-element-assembly","provider":"HVACpartstore","version":"1.0","type":"link"}