903903 Nordyne heating element 10KW

  • $ 326.40
    Unit price per 
  • Save $ 22.85
Shipping calculated at checkout.


903903 Nordyne heating element 10KW

The 903903 Heating Element Assembly is a replacement 10 kW electric furnace heating element designed for select Nordyne, Intertherm, Miller, Frigidaire, Gibson, and Maytag electric furnaces. This complete heat strip assembly restores original heating performance when existing elements become damaged, burned open, or fail due to age and normal operation. Built for dependable electric heat production, the 903903 assembly helps maintain safe, reliable, and efficient furnace performance during peak heating demands.


Cross‑Reference

  • 903903
  • Nordyne 903903
  • Intertherm 903903
  • Miller 903903
  • 10 kW Heating Element Assembly
  • Electric Furnace Heat Strip Assembly

Direct OEM

Direct replacement heating element assembly for Nordyne electric furnace applications.


Compatible Brands

  • Nordyne
  • Intertherm
  • Miller
  • Frigidaire
  • Gibson
  • Maytag
  • Tappan

Always verify model and serial number compatibility before ordering.


Application

  • Electric Furnaces
  • Electric Heat Strip Systems
  • Residential Electric Heating Equipment
  • Replacement Heater Assemblies
  • Electric Air Handlers

Specifications

  • Heating Capacity: 10 kW
  • Type: Electric Heating Element Assembly
  • Application: Furnace Heat Strip Replacement
  • Installation: Direct Replacement Assembly

Related Components

  • Limit Switches 

    626513R Nordyne limit switch L200-50F Not included 

  • Heating Element Coils
  • Heater Sequencers
  • Blower Motors
  • Blower Wheels
  • Control Boards
  • Contactors
  • Fan Relays
  • Wiring Harnesses
  • Terminal Blocks

Technician Notes

  • Inspect all safety controls before energizing a new heating element.
  • Verify proper airflow to prevent premature limit trips.
  • Check sequencers and relays for proper staging operation.
  • Examine wiring and terminals for signs of overheating.
  • Confirm voltage and amperage draw after installation.
  • Replace damaged insulation and electrical connectors as needed.

Common Symptoms of Failure

  • No Heat
  • Partial Heat Output
  • Burned or Broken Heater Coils
  • Furnace Runs but Does Not Heat
  • Frequent Limit Switch Trips
  • Uneven Heat Staging
  • Extended Heating Cycles
  • Reduced Heating Capacity
  • Visible Damage to Heat Strips

Installation Tips

  1. Disconnect all electrical power before servicing.
  2. Verify replacement element specifications.
  3. Label all wiring connections before removal.
  4. Inspect sequencers, limits, and contactors.
  5. Remove the damaged heating assembly.
  6. Install the replacement heater securely.
  7. Tighten all electrical terminals.
  8. Restore power and test furnace operation.
  9. Verify proper current draw and temperature rise.

Recommended Inspection Items

  • High-Limit Switches
  • Heater Sequencers
  • Blower Motor
  • Blower Wheel
  • Wiring Connections
  • Electrical Terminals
  • Heater Rack Assembly
  • Control Board
  • Air Filter
  • Supply Air Temperature Rise

The 903903-heating element is used in several E2EH and E2EB Series electric furnaces, including:

Furnace Model Prefix Typical Applications
E2EH010HB Mobile home electric furnace (10kW)
E2EH020HB Dual-element staging (requires 2× 903903)
E2EH023HB High-output electric furnace (10kW + 5kW)
E2EB010HB Residential electric furnace (10kW)
E2EB020HB Staged heating configurations
E2EB023HB Multi-stage electric heat setups

These units are commonly found in mobile homes, modular housing, and light residential applications.