{"product_id":"90-t40f3-copeland-comfort-control-white-rodgers-transformer-40va-multi","title":"90-T40F3 Copeland Comfort Control (White Rodgers) Transformer 40VA Multi","description":"\u003ch1\u003e90-T40F3 Copeland Comfort Control (White Rodgers) Transformer 40VA Multi\u003c\/h1\u003e\n\u003cstyle\u003e\na {\n    text-decoration: none;\n    color: #464feb;\n}\ntr th, tr td {\n    border: 1px solid #e6e6e6;\n}\ntr th {\n    background-color: #f5f5f5;\n}\n\u003c\/style\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e90-T40F3\u003c\/td\u003e\n\u003ctd\u003e40 VA\u003c\/td\u003e\n\u003ctd\u003e120\/208\/240V\u003c\/td\u003e\n\u003ctd\u003e24 VAC\u003c\/td\u003e\n\u003ctd\u003eFoot Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cmeta content=\"text\/html; charset=us-ascii\" http-equiv=\"Content-Type\"\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cstyle\u003e\na {\n    text-decoration: none;\n    color: #464feb;\n}\ntr th, tr td {\n    border: 1px solid #e6e6e6;\n}\ntr th {\n    background-color: #f5f5f5;\n}\n\u003c\/style\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe \u003cstrong\u003e90-T40F3 Copeland Comfort Control \/ White-Rodgers Transformer\u003c\/strong\u003e is a versatile 40VA foot-mount control transformer designed for HVAC, refrigeration, and equipment control applications. Features multi-voltage 120\/208\/240V primary inputs and a regulated 24 VAC secondary output for reliable operation of thermostats, relays, contactors, gas valves, and control circuits.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eCross-Reference\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWhite-Rodgers 90-T40F3\u003c\/li\u003e\n\u003cli\u003eCopeland Comfort Control 90-T40F3\u003c\/li\u003e\n\u003cli\u003eEmerson 90-T40F3\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eDirect OEM\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCopeland Comfort Control\u003c\/li\u003e\n\u003cli\u003eWhite-Rodgers\u003c\/li\u003e\n\u003cli\u003eEmerson\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eCompatible Brands\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eColeman\u003c\/li\u003e\n\u003cli\u003eEvcon\u003c\/li\u003e\n\u003cli\u003eYork\u003c\/li\u003e\n\u003cli\u003eLuxaire\u003c\/li\u003e\n\u003cli\u003eFraser-Johnston\u003c\/li\u003e\n\u003cli\u003eGoodman\u003c\/li\u003e\n\u003cli\u003eAmana\u003c\/li\u003e\n\u003cli\u003eRheem\u003c\/li\u003e\n\u003cli\u003eRuud\u003c\/li\u003e\n\u003cli\u003eTrane\u003c\/li\u003e\n\u003cli\u003eAmerican Standard\u003c\/li\u003e\n\u003cli\u003eCarrier\u003c\/li\u003e\n\u003cli\u003eBryant\u003c\/li\u003e\n\u003cli\u003ePayne\u003c\/li\u003e\n\u003cli\u003eLennox\u003c\/li\u003e\n\u003cli\u003eDucane\u003c\/li\u003e\n\u003cli\u003eHeil\u003c\/li\u003e\n\u003cli\u003eTempstar\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eApplication\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHVAC control circuits\u003c\/li\u003e\n\u003cli\u003eFurnace transformer replacement\u003c\/li\u003e\n\u003cli\u003eAir conditioner controls\u003c\/li\u003e\n\u003cli\u003eHeat pump control systems\u003c\/li\u003e\n\u003cli\u003eRefrigeration equipment controls\u003c\/li\u003e\n\u003cli\u003eThermostat power supply\u003c\/li\u003e\n\u003cli\u003eRelay and contactor control circuits\u003c\/li\u003e\n\u003cli\u003eGas valve control systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eRelated Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThermostats\u003c\/li\u003e\n\u003cli\u003eFan relays\u003c\/li\u003e\n\u003cli\u003eControl boards\u003c\/li\u003e\n\u003cli\u003eSequencers\u003c\/li\u003e\n\u003cli\u003eContactors\u003c\/li\u003e\n\u003cli\u003eGas valves\u003c\/li\u003e\n\u003cli\u003eLimit switches\u003c\/li\u003e\n\u003cli\u003e24 VAC relays\u003c\/li\u003e\n\u003cli\u003eTransformer fuses\u003c\/li\u003e\n\u003cli\u003eCircuit breakers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnician Notes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMulti-tap primary allows use on 120V, 208V, or 240V systems.\u003c\/li\u003e\n\u003cli\u003eProvides standard 24 VAC control voltage required by most HVAC equipment.\u003c\/li\u003e\n\u003cli\u003eFoot-mount design simplifies installation in furnace and control compartments.\u003c\/li\u003e\n\u003cli\u003eVerify primary voltage connection before energizing transformer.\u003c\/li\u003e\n\u003cli\u003eEnsure VA rating meets total connected load requirements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eCommon Symptoms of Failure\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNo 24 VAC output\u003c\/li\u003e\n\u003cli\u003eThermostat display blank\u003c\/li\u003e\n\u003cli\u003eContactor not energizing\u003c\/li\u003e\n\u003cli\u003eFurnace completely inoperative\u003c\/li\u003e\n\u003cli\u003eControl board not powering up\u003c\/li\u003e\n\u003cli\u003eBlown low-voltage fuse\u003c\/li\u003e\n\u003cli\u003eIntermittent control circuit operation\u003c\/li\u003e\n\u003cli\u003eTransformer overheating or humming excessively\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eInstallation Tips\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eDisconnect power before servicing.\u003c\/li\u003e\n\u003cli\u003eVerify incoming line voltage.\u003c\/li\u003e\n\u003cli\u003eMatch primary lead connection to supply voltage.\u003c\/li\u003e\n\u003cli\u003eConfirm secure grounding and mounting.\u003c\/li\u003e\n\u003cli\u003eCheck secondary output voltage before reconnecting controls.\u003c\/li\u003e\n\u003cli\u003eReplace any damaged low-voltage wiring.\u003c\/li\u003e\n\u003cli\u003eVerify total connected load does not exceed 40 VA rating.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003chr\u003e\n\u003ch3\u003eRecommended Inspection Items\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLow-voltage fuse condition\u003c\/li\u003e\n\u003cli\u003eThermostat wiring integrity\u003c\/li\u003e\n\u003cli\u003eContactors and relays for shorts\u003c\/li\u003e\n\u003cli\u003eControl board condition\u003c\/li\u003e\n\u003cli\u003eTransformer mounting hardware\u003c\/li\u003e\n\u003cli\u003ePrimary voltage connections\u003c\/li\u003e\n\u003cli\u003eSecondary voltage output\u003c\/li\u003e\n\u003cli\u003eWire insulation condition\u003c\/li\u003e\n\u003cli\u003eGrounding connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cmeta content=\"text\/html; charset=us-ascii\" http-equiv=\"Content-Type\"\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cstyle\u003e\na {\n    text-decoration: none;\n    color: #464feb;\n}\ntr th, tr td {\n    border: 1px solid #e6e6e6;\n}\ntr th {\n    background-color: #f5f5f5;\n}\n\u003c\/style\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ch2\u003eCommon HVAC Applications\u003c\/h2\u003e\n\u003ch3\u003e40 VA Models\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eResidential gas furnaces\u003c\/li\u003e\n\u003cli\u003eOil furnaces\u003c\/li\u003e\n\u003cli\u003eSingle-stage air handlers\u003c\/li\u003e\n\u003cli\u003eStandard 24V thermostat circuits\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e50 VA Models\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAir handlers with accessories\u003c\/li\u003e\n\u003cli\u003eHumidifier-equipped systems\u003c\/li\u003e\n\u003cli\u003eHeat pump controls\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e75 VA Models\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eZoning systems\u003c\/li\u003e\n\u003cli\u003eMultiple relays\u003c\/li\u003e\n\u003cli\u003eTwo-stage controls\u003c\/li\u003e\n\u003cli\u003eCommercial rooftop units\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e100 VA+ Models\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCommercial HVAC\u003c\/li\u003e\n\u003cli\u003eMultiple contactors\u003c\/li\u003e\n\u003cli\u003eBuilding automation controls\u003c\/li\u003e\n\u003cli\u003eLarge zoning panels\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Neuco","offers":[{"title":"Default Title","offer_id":45890354577474,"sku":"90-T40F3","price":34.98,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1071\/8320\/files\/Screenshot2026-11-03150106.png?v=1793743278","url":"https:\/\/hvacpartstoremarket.com\/products\/90-t40f3-copeland-comfort-control-white-rodgers-transformer-40va-multi","provider":"HVACpartstore","version":"1.0","type":"link"}