7995-3061 Coleman Spark Ignitor Flame Sensor

  • $ 91.37
    Unit price per 
  • Save $ 7.62
Shipping calculated at checkout.


7995-3061 Coleman Spark Ignitor Flame Sensor

The Coleman 7995‑3061 Spark Ignitor / Flame Sensor is a genuine OEM ignition electrode assembly designed for Coleman, York, Evcon, Luxaire, and Fraser‑Johnston furnaces equipped with Direct Spark Ignition (DSI) systems. This dual‑function component generates the ignition spark that lights the burners and then verifies flame presence through flame‑rectification sensing.

Built with a high‑temperature ceramic insulator and precision electrode geometry, the 7995‑3061 ensures dependable ignition, accurate flame proving, and safe furnace operation. If the control board does not detect the proper flame signal, the gas valve is closed to prevent unsafe operation.

This OEM replacement restores reliable startup performance when the original ignitor/sensor becomes cracked, carbon‑tracked, corroded, or damaged.


 Cross‑Reference 

Direct OEM

  • 7995‑3061 — Coleman Spark Ignitor / Flame Sensor
  • S1‑7995‑3061 — Source 1 OEM Number

Compatible Brands

  • Coleman
  • York
  • Evcon
  • Luxaire
  • Fraser‑Johnston

Application

  • Direct Spark Ignition (DSI) Furnaces
  • Gas Furnace Ignition Systems
  • Flame Rectification Circuits
  • Burner Ignition Assemblies

Function

  • Spark Ignition Electrode
  • Flame Sensor
  • Flame Proving Device
  • Burner Safety Verification

Related Components

  • Ignition Control Modules
  • Gas Valve Assemblies
  • Spark Wires
  • Burner Assemblies
  • Grounding Harnesses

 Technician Notes

  • Performs both ignition and flame‑sensing functions.
  • Requires proper grounding for accurate flame rectification.
  • Ceramic insulator must be free of cracks.
  • Inspect burner carryover ports during replacement.
  • Verify proper spark gap before startup.

Common Symptoms of Failure

  • No ignition spark
  • Burners ignite then shut off
  • Flame sensing faults
  • Repeated ignition attempts
  • Furnace lockout condition
  • Intermittent heating operation

Installation Tips

  • Disconnect power before servicing.
  • Clean burner and grounding surfaces.
  • Verify ignition wire condition.
  • Confirm flame signal after installation.
  • Do not bend the electrode unless specified by OEM service literature.


We Also Recommend