S1-7990-319P Coleman OEM Integrated Control Board
S1-7990-319P Coleman Integrated Control Board
In Stock
Product Description
The S1-7990-319P Integrated Control Board is a genuine OEM replacement control board designed for select Coleman®, York®, Luxaire®, and Guardian® gas furnaces. This integrated furnace control (IFC) board serves as the central control system for furnace operation, managing ignition sequencing, blower motor timing, flame sensing, safety monitoring, and diagnostic functions. Replacing a failed control board can restore reliable heating performance and proper furnace operation.
Manufactured to OEM specifications for dependable compatibility and long service life.
Features
- Genuine OEM Coleman replacement part
- Integrated Furnace Control (IFC) Board
- Controls ignition and burner operation
- Manages blower motor timing and fan delays
- Monitors flame sensing and safety circuits
- Built-in diagnostic capabilities
- Direct-fit OEM replacement
- Reliable electronic control performance
Technical Notes
- Part Number: S1-7990-319P
- Product Type: Integrated Control Board
- Application: Gas Furnaces
- OEM Replacement Component
- Controls ignition sequence, blower operation, flame detection, and safety functions
- Supports system diagnostics and troubleshooting
- Verify original board number and furnace compatibility before ordering
- Professional installation recommended
Cross Reference
- S1-7990-319P
- 7990-319P
- Coleman Integrated Control Board
- Coleman IFC Board
- Furnace Control Board
- OEM Furnace Control Board
- Integrated Furnace Control Module
- York Control Board
- Luxaire Control Board
Fits Models
Compatible with select furnaces manufactured by:
- Coleman®
- York®
- Luxaire®
- Guardian®
Always verify the original board part number and furnace model before ordering.
Sometimes referred to as a circuit board or ignition control. For a spare or replacement fuse, order a
ATC-3 BUSSMANN 3 AMP FUSE
Replaces 7956-319, 7956-319P, 7990-318, 7990-318/A, 7990-318P, 7990-318P/A & 7990-319. 7990-319P, ICM2801.
Diagnostic Flash Codes
Steady light on - normal operation.
One flash - ignition failure.
Two flashes - combustion air switch stuck closed.
Three flashes - combustion air switch failed to close.
Four flashes - limit switch open.
Five flashes - gas valve energized with no call for heat.
Rapid flashing - reversed polarity.
Note: Color of light is green.