{"product_id":"69281-3-aerco-boiler-protoair-gateway-kit-bacnet","title":"69281-3 AERCO Boiler PROTOAIR GATEWAY KIT-BACNET","description":"\u003ch1\u003e69281-3 AERCO Boiler PROTOAIR GATEWAY KIT-BACNET\u003c\/h1\u003e\n\u003ch2\u003e \u003cspan style=\"background-color: rgb(255, 255, 0);\"\u003eNormal Stocking Item in our Warehouse\u003c\/span\u003e \u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eAERCO 69281‑3 ProtoAir Gateway Kit (BACnet)\u003c\/strong\u003e — OEM multi‑protocol gateway for AERCO boilers and water heaters. Provides seamless integration with BACnet IP\/MS‑TP, Modbus TCP\/RTU, and Metasys N2 building‑automation systems. Supports up to 16 units per gateway, auto‑discovers RS‑485 devices, and enables real‑time monitoring, sequencing, and remote access. Includes DIN‑rail mounting and full OEM configuration profiles.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eAERCO 69281‑3 is the official \u003c\/strong\u003e\u003cem\u003e\u003cstrong\u003eProtoAir Gateway Kit – BACnet\u003c\/strong\u003e\u003c\/em\u003e, a multi‑protocol building‑automation gateway designed to integrate AERCO boilers and water heaters with BACnet, Modbus, Metasys N2, and other BAS platforms. This identification, feature set, and specifications are fully confirmed by AERCO’s own technical documentation. \u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"relative pb-6 w-full after:border-b after:border-stroke-300 after:w-full after:absolute after:mt-3\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch2\u003e \u003cstrong\u003eCore Identity \u0026amp; Purpose\u003c\/strong\u003e\n\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e 69281‑3 \u003cstrong\u003eComponent:\u003c\/strong\u003e ProtoAir Gateway Kit (BACnet‑enabled) \u003cstrong\u003eOEM:\u003c\/strong\u003e AERCO\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis gateway provides \u003cstrong\u003efull BAS integration\u003c\/strong\u003e for AERCO equipment, enabling centralized monitoring, sequencing, and control. It is used across commercial, industrial, and institutional facilities.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eKey functions:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul role=\"list\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIntegrates AERCO boilers\/water heaters with \u003cstrong\u003eBACnet IP\u003c\/strong\u003e, \u003cstrong\u003eBACnet MS\/TP\u003c\/strong\u003e, \u003cstrong\u003eModbus TCP\/IP\u003c\/strong\u003e, \u003cstrong\u003eModbus RTU\u003c\/strong\u003e, and \u003cstrong\u003eMetasys N2\u003c\/strong\u003e. \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"ps-2\"\u003e\n\u003cp\u003e\u003cspan\u003eAllows \u003cstrong\u003ereal‑time performance monitoring\u003c\/strong\u003e and \u003cstrong\u003eremote access\u003c\/strong\u003e for proactive maintenance. \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"ps-2\"\u003e\n\u003cp\u003e\u003cspan\u003eSupports \u003cstrong\u003eup to 16 units per gateway\u003c\/strong\u003e in sequenced heating\/hot‑water plants. \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"ps-2\"\u003e\n\u003cp\u003e\u003cspan\u003eAuto‑discovers RS‑485 devices and supports up to \u003cstrong\u003e32 AERCO nodes\u003c\/strong\u003e on a single gateway. \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"relative pb-6 w-full after:border-b after:border-stroke-300 after:w-full after:absolute after:mt-3\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch2\u003e \u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\n\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eFrom AERCO’s technical data sheet: \u003c\/span\u003e\u003c\/p\u003e\n\u003cul role=\"list\" class=\"relative list-outside marker:text-foreground-750 dark:marker:text-foreground-600 flex flex-col ms-4 px-1\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eInput Voltage:\u003c\/strong\u003e 12–24 VDC or 24 VAC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMax Power:\u003c\/strong\u003e 3 W\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePorts:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul role=\"list\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRS‑485\/RS‑232\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRS‑485 field port\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePower port\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eEthernet 10\/100 Base‑T\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWi‑Fi:\u003c\/strong\u003e 802.11 b\/g\/n (2.4 GHz)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp:\u003c\/strong\u003e –4°F to 158°F (–20°C to 70°C)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eHumidity:\u003c\/strong\u003e 10–95% RH, non‑condensing\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e 4 × 1.1 × 2.7 in\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.4 lb\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eApprovals:\u003c\/strong\u003e BTL, Modbus, FCC, CE, DNP, WEEE, RoHS, REACH, UKCA, ODVA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch2\u003e \u003cstrong\u003eWhere It’s Used\u003c\/strong\u003e\n\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eCompatible with:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul role=\"list\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAERCO boilers with \u003cstrong\u003eEdge\u003c\/strong\u003e or \u003cstrong\u003eC‑More\u003c\/strong\u003e controllers\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eModulex EXT\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAM Series\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSmartPlate\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eElectronically controlled indirect water heaters \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eThis kit is required for \u003cstrong\u003eBACnet MS\/TP\u003c\/strong\u003e or \u003cstrong\u003eModbus RTU\u003c\/strong\u003e communication on Edge [i] controllers. \u003c\/span\u003e\u003c\/p\u003e","brand":"Neuco","offers":[{"title":"Default Title","offer_id":42886177194050,"sku":"69281-3","price":5185.1,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1071\/8320\/files\/Screenshot_2026-09-07_051929.png?v=1788783595","url":"https:\/\/hvacpartstoremarket.com\/products\/69281-3-aerco-boiler-protoair-gateway-kit-bacnet","provider":"HVACpartstore","version":"1.0","type":"link"}