{"product_id":"668-430-copeland-comfort-control-white-rodgers-intermittent-ignition","title":"668-430 Copeland Comfort Control (White Rodgers) Intermittent Ignition","description":"\u003ch1\u003e668-430 Copeland Comfort Control (White Rodgers) Intermittent Ignition\u003c\/h1\u003e\n\u003cstyle\u003e\na {\n    text-decoration: none;\n    color: #464feb;\n}\ntr th, tr td {\n    border: 1px solid #e6e6e6;\n}\ntr th {\n    background-color: #f5f5f5;\n}\n\u003c\/style\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe \u003cstrong\u003e668-430 Copeland Comfort Control \/ White-Rodgers Intermittent Ignition Control\u003c\/strong\u003e is an OEM ignition module designed to provide safe and reliable ignition sequencing in gas-fired heating equipment. This intermittent ignition control monitors the ignition process, energizes the gas valve, verifies flame presence, and safely shuts down the system if ignition is not proven. Commonly used in furnaces, unit heaters, boilers, and other gas heating applications requiring dependable electronic ignition control.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eCross-Reference\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWhite-Rodgers 668-430\u003c\/li\u003e\n\u003cli\u003eCopeland Comfort Control 668-430\u003c\/li\u003e\n\u003cli\u003eEmerson 668-430\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eDirect OEM\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCopeland Comfort Control\u003c\/li\u003e\n\u003cli\u003eWhite-Rodgers\u003c\/li\u003e\n\u003cli\u003eEmerson\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eCompatible Brands\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eColeman\u003c\/li\u003e\n\u003cli\u003eYork\u003c\/li\u003e\n\u003cli\u003eLuxaire\u003c\/li\u003e\n\u003cli\u003eFraser-Johnston\u003c\/li\u003e\n\u003cli\u003eEvcon\u003c\/li\u003e\n\u003cli\u003eGoodman\u003c\/li\u003e\n\u003cli\u003eAmana\u003c\/li\u003e\n\u003cli\u003eRheem\u003c\/li\u003e\n\u003cli\u003eRuud\u003c\/li\u003e\n\u003cli\u003eCarrier\u003c\/li\u003e\n\u003cli\u003eBryant\u003c\/li\u003e\n\u003cli\u003ePayne\u003c\/li\u003e\n\u003cli\u003eLennox\u003c\/li\u003e\n\u003cli\u003eHeil\u003c\/li\u003e\n\u003cli\u003eTempstar\u003c\/li\u003e\n\u003cli\u003eArmstrong Air\u003c\/li\u003e\n\u003cli\u003eVarious OEM gas-fired heating systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eApplication\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eGas furnaces\u003c\/li\u003e\n\u003cli\u003eUnit heaters\u003c\/li\u003e\n\u003cli\u003eGas boilers\u003c\/li\u003e\n\u003cli\u003eCommercial heating equipment\u003c\/li\u003e\n\u003cli\u003eIntermittent pilot ignition systems\u003c\/li\u003e\n\u003cli\u003eElectronic ignition heating controls\u003c\/li\u003e\n\u003cli\u003eOEM replacement ignition modules\u003c\/li\u003e\n\u003cli\u003eResidential and light commercial gas appliances\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eRelated Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFlame sensors\u003c\/li\u003e\n\u003cli\u003eIgnition electrodes\u003c\/li\u003e\n\u003cli\u003eSpark ignitors\u003c\/li\u003e\n\u003cli\u003eGas valves\u003c\/li\u003e\n\u003cli\u003ePressure switches\u003c\/li\u003e\n\u003cli\u003eRollout switches\u003c\/li\u003e\n\u003cli\u003eLimit switches\u003c\/li\u003e\n\u003cli\u003eControl transformers\u003c\/li\u003e\n\u003cli\u003eFurnace control boards\u003c\/li\u003e\n\u003cli\u003eThermostats\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnician Notes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eProvides automatic ignition sequencing and flame monitoring.\u003c\/li\u003e\n\u003cli\u003eDesigned for intermittent ignition system applications.\u003c\/li\u003e\n\u003cli\u003eVerifies flame presence before maintaining gas valve operation.\u003c\/li\u003e\n\u003cli\u003eSafety lockout helps prevent unignited gas accumulation.\u003c\/li\u003e\n\u003cli\u003eInspect ignition wiring, ground connections, and flame sensing circuits when troubleshooting.\u003c\/li\u003e\n\u003cli\u003eAlways verify compatibility with the appliance manufacturer's specifications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eCommon Symptoms of Failure\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNo ignition spark\u003c\/li\u003e\n\u003cli\u003ePilot fails to light\u003c\/li\u003e\n\u003cli\u003eMain burner will not ignite\u003c\/li\u003e\n\u003cli\u003eIgnition lockout condition\u003c\/li\u003e\n\u003cli\u003eIntermittent heating operation\u003c\/li\u003e\n\u003cli\u003eBurner shuts off unexpectedly\u003c\/li\u003e\n\u003cli\u003eFailure to prove flame\u003c\/li\u003e\n\u003cli\u003eRepeated trial-for-ignition cycles\u003c\/li\u003e\n\u003cli\u003eFurnace runs but does not fire\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eInstallation Tips\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eDisconnect power before servicing.\u003c\/li\u003e\n\u003cli\u003eVerify model number and ignition system compatibility.\u003c\/li\u003e\n\u003cli\u003eInspect flame sensor and ignitor condition before replacement.\u003c\/li\u003e\n\u003cli\u003eConfirm proper grounding of the ignition control circuit.\u003c\/li\u003e\n\u003cli\u003eCheck gas valve operation and wiring connections.\u003c\/li\u003e\n\u003cli\u003eVerify safety switches are operating correctly.\u003c\/li\u003e\n\u003cli\u003eTest complete ignition sequence after installation.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003chr\u003e\n\u003ch3\u003eRecommended Inspection Items\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFlame sensor condition\u003c\/li\u003e\n\u003cli\u003eIgnitor electrode condition\u003c\/li\u003e\n\u003cli\u003eGround connections\u003c\/li\u003e\n\u003cli\u003eGas valve operation\u003c\/li\u003e\n\u003cli\u003ePressure switch function\u003c\/li\u003e\n\u003cli\u003eRollout switch continuity\u003c\/li\u003e\n\u003cli\u003eHigh-limit switch operation\u003c\/li\u003e\n\u003cli\u003eControl transformer output\u003c\/li\u003e\n\u003cli\u003eWiring harness condition\u003c\/li\u003e\n\u003cli\u003eVenting system restrictions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Quinn","offers":[{"title":"Default Title","offer_id":45892228284482,"sku":"60-668-430","price":121.25,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1071\/8320\/files\/Screenshot2026-11-03202058.png?v=1793762473","url":"https:\/\/hvacpartstoremarket.com\/products\/668-430-copeland-comfort-control-white-rodgers-intermittent-ignition","provider":"HVACpartstore","version":"1.0","type":"link"}