660575R Nordyne Pilot Assembly L.P & NAT

660575R Nordyne Pilot Assembly L.P & NAT

  • $ 46.89
    Unit price per 
  • Save $ 6.10
Shipping calculated at checkout.


660575R Nordyne Pilot Assembly L.P & NAT

The 660575R Nordyne Pilot Assembly is a genuine OEM replacement pilot burner assembly designed for use with both Liquid Propane (LP) and Natural Gas (NG) heating applications. This pilot assembly provides a reliable ignition source for standing pilot systems, ensuring proper flame stability, thermocouple heating, and dependable burner operation. Commonly used in Nordyne manufactured furnaces and compatible heating equipment, the 660575R helps restore safe and efficient operation when replacing a damaged, worn, or malfunctioning pilot assembly.


Cross-Reference

  • 660575R
  • Nordyne 660575R
  • Nortek 660575R
  • Pilot Assembly 660575R

Direct OEM

Yes

Genuine Nordyne OEM replacement part.


Compatible Brands

  • Nordyne
  • Intertherm
  • Miller
  • Frigidaire
  • Maytag
  • Gibson
  • Tappan
  • Broan
  • NuTone
  • Philco

Application

Designed for standing pilot ignition systems operating on:

  • Natural Gas (NG)
  • Liquid Propane (LP)

Commonly used in:

  • Gas Furnaces
  • Mobile Home Furnaces
  • Manufactured Housing Furnaces
  • Residential Heating Equipment
  • Standing Pilot Systems
  • Replacement Pilot Burner Assemblies

Always verify model compatibility before ordering.


Related Components

  • Thermocouples
  • Gas Valves
  • Pilot Orifices
  • Pilot Tubing
  • Burner Assemblies
  • Ignition Components
  • Flame Safety Controls
  • Furnace Service Parts

Technician Notes

  • Genuine OEM Nordyne pilot assembly.
  • Supports both LP and Natural Gas applications when configured with the correct orifice.
  • Inspect thermocouple alignment and flame impingement after installation.
  • Verify pilot flame is stable and properly contacts the thermocouple.
  • Check pilot tubing and gas valve operation during service.
  • Replace damaged pilot assemblies that exhibit corrosion, blockage, or unstable flame characteristics.

Common Symptoms of Failure

  • Pilot will not light
  • Pilot will not stay lit
  • Weak or unstable pilot flame
  • Delayed burner ignition
  • Thermocouple not heating properly
  • Frequent system shutdowns
  • Intermittent heating operation
  • Pilot burner contamination or damage

Installation Tips

  1. Shut off electrical power and gas supply before servicing.
  2. Verify fuel type and equipment compatibility.
  3. Remove the old pilot assembly and inspect surrounding components.
  4. Check pilot tubing and gas connections for wear or damage.
  5. Install the new 660575R pilot assembly securely.
  6. Leak-test all gas connections before operation.
  7. Verify proper pilot flame appearance and thermocouple engagement.
  8. Follow OEM service procedures and local gas codes.

Recommended Inspection Items

  • Thermocouple condition
  • Pilot flame quality
  • Pilot tubing condition
  • Gas valve operation
  • Burner ignition sequence
  • Heat exchanger condition
  • Venting system
  • Gas supply pressure
  • Combustion air openings