{"product_id":"660149r-nordyne-lp-pilot-orifice-10-010","title":"660149R Nordyne LP Pilot Orifice  #10 (.010\")","description":"\u003ch1\u003e660149R Nordyne LP Pilot Orifice #10 (.010\")\u003c\/h1\u003e\n\u003cstyle\u003e\na {\n    text-decoration: none;\n    color: #464feb;\n}\ntr th, tr td {\n    border: 1px solid #e6e6e6;\n}\ntr th {\n    background-color: #f5f5f5;\n}\n\u003c\/style\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe \u003cstrong\u003e660149R Nordyne LP Pilot Orifice #10\u003c\/strong\u003e is a genuine OEM replacement pilot orifice designed for liquid propane (LP) gas heating equipment. Featuring a precision-drilled \u003cstrong\u003e0.010-inch (#10) orifice opening\u003c\/strong\u003e, this component regulates pilot gas flow to maintain proper flame characteristics, dependable ignition performance, and reliable thermocouple operation. Commonly used in Nordyne-manufactured equipment and associated brands, the 660149R helps restore safe and efficient operation when replacing a clogged, damaged, or worn pilot orifice.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eCross-Reference\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e660149R\u003c\/li\u003e\n\u003cli\u003eNordyne 660149R\u003c\/li\u003e\n\u003cli\u003eNortek 660149R\u003c\/li\u003e\n\u003cli\u003ePilot Orifice #10\u003c\/li\u003e\n\u003cli\u003eLP Pilot Orifice .010\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eDirect OEM\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eGenuine Nordyne OEM replacement part.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eCompatible Brands\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eNordyne\u003c\/li\u003e\n\u003cli\u003eIntertherm\u003c\/li\u003e\n\u003cli\u003eMiller\u003c\/li\u003e\n\u003cli\u003eMaytag\u003c\/li\u003e\n\u003cli\u003eFrigidaire\u003c\/li\u003e\n\u003cli\u003eBroan\u003c\/li\u003e\n\u003cli\u003eTappan\u003c\/li\u003e\n\u003cli\u003eGibson\u003c\/li\u003e\n\u003cli\u003ePhilco\u003c\/li\u003e\n\u003cli\u003eNuTone\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eApplication\u003c\/h2\u003e\n\u003cp\u003eDesigned for \u003cstrong\u003eLP (Liquid Propane) gas\u003c\/strong\u003e pilot burner applications requiring a \u003cstrong\u003e#10 (.010\") pilot orifice\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eCommonly used in:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMobile Home Furnaces\u003c\/li\u003e\n\u003cli\u003eManufactured Housing Furnaces\u003c\/li\u003e\n\u003cli\u003eResidential Gas Furnaces\u003c\/li\u003e\n\u003cli\u003eUnit Heaters\u003c\/li\u003e\n\u003cli\u003eLP Conversion Applications\u003c\/li\u003e\n\u003cli\u003eStanding Pilot Systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAlways verify equipment compatibility using the model number and parts list before ordering.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eRelated Components\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003ePilot Burner Assemblies\u003c\/li\u003e\n\u003cli\u003eThermocouples\u003c\/li\u003e\n\u003cli\u003eGas Valves\u003c\/li\u003e\n\u003cli\u003ePilot Tubing\u003c\/li\u003e\n\u003cli\u003eFlame Sensors\u003c\/li\u003e\n\u003cli\u003eIgnition Components\u003c\/li\u003e\n\u003cli\u003eBurners\u003c\/li\u003e\n\u003cli\u003eLP Conversion Components\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnician Notes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned specifically for LP gas applications.\u003c\/li\u003e\n\u003cli\u003eFeatures a precision \u003cstrong\u003e0.010-inch (#10)\u003c\/strong\u003e orifice opening.\u003c\/li\u003e\n\u003cli\u003eEven minor contamination can significantly affect pilot flame quality.\u003c\/li\u003e\n\u003cli\u003eInspect pilot tubing and burner ports when replacing the orifice.\u003c\/li\u003e\n\u003cli\u003eVerify LP supply pressure and pilot adjustment during service.\u003c\/li\u003e\n\u003cli\u003eAlways confirm the correct orifice size for the equipment being serviced.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eCommon Symptoms of Failure\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003ePilot will not light\u003c\/li\u003e\n\u003cli\u003eWeak pilot flame\u003c\/li\u003e\n\u003cli\u003ePilot repeatedly goes out\u003c\/li\u003e\n\u003cli\u003eDelayed main burner ignition\u003c\/li\u003e\n\u003cli\u003eIntermittent heating operation\u003c\/li\u003e\n\u003cli\u003eInsufficient thermocouple heating\u003c\/li\u003e\n\u003cli\u003eRestricted pilot gas flow\u003c\/li\u003e\n\u003cli\u003eNuisance shutdowns\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eInstallation Tips\u003c\/h2\u003e\n\u003col\u003e\n\u003cli\u003eDisconnect electrical power and shut off gas supply.\u003c\/li\u003e\n\u003cli\u003eConfirm the appliance is configured for LP gas.\u003c\/li\u003e\n\u003cli\u003eRemove the existing orifice carefully to avoid thread damage.\u003c\/li\u003e\n\u003cli\u003eInspect the pilot assembly for dirt or debris.\u003c\/li\u003e\n\u003cli\u003eInstall the new 660149R orifice securely.\u003c\/li\u003e\n\u003cli\u003eLeak-test all gas connections after reassembly.\u003c\/li\u003e\n\u003cli\u003eVerify proper pilot flame pattern and thermocouple engagement.\u003c\/li\u003e\n\u003cli\u003eFollow OEM service procedures and local codes.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003chr\u003e\n\u003ch2\u003eRecommended Inspection Items\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eThermocouple condition\u003c\/li\u003e\n\u003cli\u003ePilot burner cleanliness\u003c\/li\u003e\n\u003cli\u003eGas valve operation\u003c\/li\u003e\n\u003cli\u003eLP gas supply pressure\u003c\/li\u003e\n\u003cli\u003ePilot tubing condition\u003c\/li\u003e\n\u003cli\u003eBurner ignition sequence\u003c\/li\u003e\n\u003cli\u003eVenting system condition\u003c\/li\u003e\n\u003cli\u003eFlame stability and appearance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Quinn","offers":[{"title":"Default Title","offer_id":45561363071042,"sku":"660149R","price":19.88,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1071\/8320\/files\/660149r-3.jpg?v=1756772235","url":"https:\/\/hvacpartstoremarket.com\/products\/660149r-nordyne-lp-pilot-orifice-10-010","provider":"HVACpartstore","version":"1.0","type":"link"}