{"product_id":"6461-150-aerco-boiler-relief-valve-1-150-psi","title":"6461-150 AERCO Boiler RELIEF VALVE 1\" 150 PSI","description":"\u003ch1\u003e6461-150 AERCO Boiler RELIEF VALVE 1\" 150 PSI\u003c\/h1\u003e\n\u003cp\u003e\u003cspan style=\"background-color: rgb(255, 255, 0);\"\u003e\u003cb\u003e\u003cspan style=\"font-size: large; background-color: rgb(255, 255, 0);\"\u003eNormal Stocking Item in Our Warehouse \u003c\/span\u003e\u003c\/b\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eAERCO 6461‑150 is the OEM 1″, 150 PSI Relief Valve\u003c\/strong\u003e used on AERCO boilers and water heaters. Grounded distributor data confirms its specifications, function, and availability.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003eAERCO 6461‑150 Relief Valve (1″, 150 PSI) — OEM safety valve for AERCO boilers and water heaters. Automatically opens at 150 PSI to protect piping, heat exchangers, and equipment from over‑pressurization. Heavy‑duty construction ensures reliable performance in commercial hydronic and hot‑water systems.\u003c\/div\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003ch2\u003e Core Identity \u0026amp; Function\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePart Number:\u003c\/strong\u003e 6461‑150 \u003cstrong\u003eComponent:\u003c\/strong\u003e Pressure Relief Valve \u003cstrong\u003eSize:\u003c\/strong\u003e 1″ NPT \u003cstrong\u003ePressure Rating:\u003c\/strong\u003e 150 PSI \u003cstrong\u003eOEM:\u003c\/strong\u003e AERCO\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis valve provides \u003cstrong\u003eover‑pressure protection\u003c\/strong\u003e for hydronic and hot‑water systems. When system pressure exceeds \u003cstrong\u003e150 PSI\u003c\/strong\u003e, the valve automatically opens to discharge excess pressure, then reseats once pressure returns to safe levels.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis prevents:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul role=\"list\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHeat‑exchanger damage\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePiping rupture\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eUnsafe boiler operation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCode violations\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eGrounded sources confirm it is engineered specifically for AERCO boiler and water‑heater assemblies. \u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul role=\"list\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eConnection:\u003c\/strong\u003e 1″ NPT\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eRelief Pressure:\u003c\/strong\u003e 150 PSI\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e Boiler \u0026amp; hydronic heating systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eOperation:\u003c\/strong\u003e Automatic pressure relief \/ automatic reseat\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e Heavy‑duty commercial HVAC grade\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eUsed in:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul role=\"list\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAERCO Benchmark boilers\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAERCO water heaters\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCommercial hydronic loops\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eHot‑water supply systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eTypical replacement scenarios:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul role=\"list\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRelief valve weeping or stuck open\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSystem pressure creeping above 150 PSI\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAnnual safety‑device replacement\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCode‑required maintenance\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Neuco","offers":[{"title":"Default Title","offer_id":42447041396802,"sku":"6461-150","price":552.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1071\/8320\/files\/Screenshot_2026-09-06_193409.png?v=1788748497","url":"https:\/\/hvacpartstoremarket.com\/products\/6461-150-aerco-boiler-relief-valve-1-150-psi","provider":"HVACpartstore","version":"1.0","type":"link"}