{"product_id":"64088-aerco-boiler-limit-control-digital","title":"64088 AERCO Boiler LIMIT CONTROL DIGITAL","description":"\u003ch1\u003e64088 AERCO Boiler LIMIT CONTROL DIGITAL\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan style=\"background-color: rgb(255, 255, 0);\"\u003eNormal Stock Item \u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cmeta content=\"text\/html; charset=us-ascii\" http-equiv=\"Content-Type\"\u003e\u003c\/p\u003e\n\u003cstyle\u003e\na {\n    text-decoration: none;\n    color: #464feb;\n}\ntr th, tr td {\n    border: 1px solid #e6e6e6;\n}\ntr th {\n    background-color: #f5f5f5;\n}\n\u003c\/style\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe \u003cstrong\u003e64088 AERCO Digital Limit Control\u003c\/strong\u003e is a genuine OEM electronic safety control designed for use in compatible AERCO commercial boilers and water heaters. This digital limit control continuously monitors system temperatures and provides critical over-temperature protection by interrupting operation when programmed safety limits are exceeded. As an essential safety component, the 64088 helps protect heat exchangers, combustion systems, and other critical equipment from damage caused by excessive operating temperatures.\u003c\/p\u003e\n\u003cp\u003eManufactured to AERCO specifications, the Digital Limit Control delivers precise temperature monitoring, dependable safety protection, and reliable performance in commercial heating and domestic hot water applications.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eCross-Reference\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e64088\u003c\/li\u003e\n\u003cli\u003eAERCO 64088\u003c\/li\u003e\n\u003cli\u003eDigital Limit Control\u003c\/li\u003e\n\u003cli\u003eElectronic Limit Control\u003c\/li\u003e\n\u003cli\u003eHigh Limit Control\u003c\/li\u003e\n\u003cli\u003eTemperature Safety Control\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eDirect OEM\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eYes\u003c\/strong\u003e – Genuine AERCO OEM replacement digital limit control.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eCompatible Brands\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eAERCO\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompatible with select:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAERCO Commercial Boilers\u003c\/li\u003e\n\u003cli\u003eAERCO Commercial Water Heaters\u003c\/li\u003e\n\u003cli\u003eAERCO Benchmark Boilers\u003c\/li\u003e\n\u003cli\u003eAERCO High-Efficiency Heating Systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAlways verify compatibility using the equipment model and serial number before ordering.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eApplication\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eCommercial boiler systems\u003c\/li\u003e\n\u003cli\u003eCommercial water heaters\u003c\/li\u003e\n\u003cli\u003eHigh-limit temperature protection\u003c\/li\u003e\n\u003cli\u003eHydronic heating systems\u003c\/li\u003e\n\u003cli\u003eSafety monitoring circuits\u003c\/li\u003e\n\u003cli\u003eOEM control replacements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eRelated Components\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eWater Outlet Temperature Sensors\u003c\/li\u003e\n\u003cli\u003eAir Inlet Temperature Sensors\u003c\/li\u003e\n\u003cli\u003eExhaust Temperature Sensors\u003c\/li\u003e\n\u003cli\u003eGas Pressure Switch Kits\u003c\/li\u003e\n\u003cli\u003eIgnition \/ Stepper Boards\u003c\/li\u003e\n\u003cli\u003eFlame Detectors\u003c\/li\u003e\n\u003cli\u003eCombustion Blowers\u003c\/li\u003e\n\u003cli\u003eAnnual Maintenance Kits\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnician Notes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eGenuine OEM AERCO safety control.\u003c\/li\u003e\n\u003cli\u003eDigital temperature monitoring and protection.\u003c\/li\u003e\n\u003cli\u003eDesigned to prevent unsafe over-temperature conditions.\u003c\/li\u003e\n\u003cli\u003eCritical component for equipment and operational safety.\u003c\/li\u003e\n\u003cli\u003eVerify all temperature sensors are functioning properly when diagnosing limit-related faults.\u003c\/li\u003e\n\u003cli\u003eAlways determine the cause of overheating before replacing the limit control.\u003c\/li\u003e\n\u003cli\u003eInspect wiring, terminals, and associated control circuits during installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eCommon Symptoms of Failure\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eBoiler lockout conditions\u003c\/li\u003e\n\u003cli\u003eHigh-limit fault codes\u003c\/li\u003e\n\u003cli\u003eUnexpected shutdowns\u003c\/li\u003e\n\u003cli\u003eIntermittent heating operation\u003c\/li\u003e\n\u003cli\u003eOver-temperature alarms\u003c\/li\u003e\n\u003cli\u003eFailure to maintain operation\u003c\/li\u003e\n\u003cli\u003eSafety control diagnostic errors\u003c\/li\u003e\n\u003cli\u003eNo heat or hot water production\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eInstallation Tips\u003c\/h2\u003e\n\u003col\u003e\n\u003cli\u003eDisconnect electrical power before servicing.\u003c\/li\u003e\n\u003cli\u003eConfirm replacement part number compatibility.\u003c\/li\u003e\n\u003cli\u003eDocument existing wiring connections before removal.\u003c\/li\u003e\n\u003cli\u003eInspect terminal connections for corrosion or heat damage.\u003c\/li\u003e\n\u003cli\u003eInstall the control according to AERCO service procedures.\u003c\/li\u003e\n\u003cli\u003eVerify proper sensor and control circuit operation.\u003c\/li\u003e\n\u003cli\u003eRestore power and clear fault codes if necessary.\u003c\/li\u003e\n\u003cli\u003eTest operation through a complete firing cycle.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003chr\u003e\n\u003ch2\u003eRecommended Inspection Items\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eWater outlet temperature sensor\u003c\/li\u003e\n\u003cli\u003eAir inlet temperature sensor\u003c\/li\u003e\n\u003cli\u003eExhaust temperature sensor\u003c\/li\u003e\n\u003cli\u003eBurner assembly\u003c\/li\u003e\n\u003cli\u003eCombustion blower\u003c\/li\u003e\n\u003cli\u003eGas valve operation\u003c\/li\u003e\n\u003cli\u003eControl board diagnostics\u003c\/li\u003e\n\u003cli\u003eCirculation system performance\u003c\/li\u003e\n\u003cli\u003eHeat exchanger condition\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Neuco","offers":[{"title":"Default Title","offer_id":45558653911106,"sku":"64088","price":901.37,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1071\/8320\/files\/Screenshot2025-12-18201111.png?v=1766113900","url":"https:\/\/hvacpartstoremarket.com\/products\/64088-aerco-boiler-limit-control-digital","provider":"HVACpartstore","version":"1.0","type":"link"}