626428R Nordyne limit switch 2-pole L170-40F
626428R Nordyne limit switch 2-pole L170-40F
The 626428R 2-Pole Limit Switch is a direct replacement furnace safety control designed to protect heating equipment from overheating conditions. Rated L170-40F, this temperature-sensitive limit switch opens the circuit when excessive temperatures are detected and automatically resets after cooling. Built in the T-O-D 64TX11 configuration, this switch is commonly used in Nordyne-manufactured equipment and serves as a replacement for multiple original part numbers across a variety of furnace models.
Cross-Reference
- 626428R
- 626428
- 626-428A
- 208472
- 626299
- 6262990
- 626304
- 6263040
- 626223
- 6262230
- L170-40F
- 64TX11
- T-O-D 64TX11
Direct OEM
Yes – Direct replacement for the original Nordyne limit switch design.
Compatible Brands
- Nordyne
- Intertherm
- Miller
- Broan
- Maytag
- Frigidaire
- Gibson
- Tappan
- Kelvinator
- Philco
Application
- Gas furnaces
- Mobile home furnaces
- Manufactured housing HVAC systems
- High-temperature safety circuits
- Heat exchanger temperature protection
- Main limit control applications
Related Components
- Fan limit controls
- Rollout switches
- Pressure switches
- Flame sensors
- Ignitors
- Control boards
- Blower motors
- High-limit safety switches
Technician Notes
- Temperature rating is 170°F open with a 40°F differential (L170-40F).
- Two-pole design opens both circuits simultaneously when limit temperature is reached.
- Repeated limit switch failures typically indicate airflow restrictions or overheating conditions.
- Verify replacement switch matches original temperature rating and mounting configuration.
- Inspect surrounding wiring for heat damage before installation.
Common Symptoms of Failure
- Furnace shuts down unexpectedly
- No heat operation
- Intermittent heating cycles
- Open limit switch fault codes
- Blower runs continuously
- Lockout conditions
- Unit overheats and trips safety controls
Installation Tips
- Disconnect electrical power before servicing.
- Verify the original switch rating matches L170-40F specifications.
- Label and transfer wires one at a time.
- Secure the switch firmly against the mounting surface.
- Check all terminals for corrosion or loose connections.
- Restore power and verify proper furnace operation.
- Confirm adequate airflow through the system.
Recommended Inspection Items
- Air filter condition
- Blower wheel cleanliness
- Blower motor performance
- Supply and return airflow
- Evaporator coil restrictions
- Venting system condition
- Heat exchanger area
- Wiring terminals and connectors
- Furnace temperature rise