{"product_id":"626291-nordyne-mac-fan-limit-control-l130f-f110-4-prong","title":"626291 Nordyne \/ MAC fan \u0026 limit control L130F \/ F110 (4 prong)","description":"\u003ch1\u003e626291 Nordyne \/ MAC fan \u0026amp; limit control L130F \/ F110 (4 prong)\u003c\/h1\u003e\n\u003cstyle\u003e\na {\n    text-decoration: none;\n    color: #464feb;\n}\ntr th, tr td {\n    border: 1px solid #e6e6e6;\n}\ntr th {\n    background-color: #f5f5f5;\n}\n\u003c\/style\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe \u003cstrong\u003eNordyne 626291 Fan \u0026amp; Limit Control Assembly\u003c\/strong\u003e is a replacement \u003cstrong\u003e4-prong combination fan and limit switch\u003c\/strong\u003e designed for Nordyne, Intertherm, Miller, and MAC mobile home furnaces. This dual snap-disc control combines blower fan operation and high-temperature safety protection into one assembly. Since the original OEM part is obsolete, each replacement is custom-built in our electronics shop to meet or exceed original safety specifications and includes a \u003cstrong\u003e1-year warranty\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eCross-Reference\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNordyne 626291\u003c\/li\u003e\n\u003cli\u003e6262910\u003c\/li\u003e\n\u003cli\u003e6260230\u003c\/li\u003e\n\u003cli\u003e6260231\u003c\/li\u003e\n\u003cli\u003e6260251\u003c\/li\u003e\n\u003cli\u003e6260380\u003c\/li\u003e\n\u003cli\u003eF110-20F\u003c\/li\u003e\n\u003cli\u003eL130-15F\u003c\/li\u003e\n\u003cli\u003eL130-40F\u003c\/li\u003e\n\u003cli\u003e6262-91\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eDirect OEM\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eNordyne 626291\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eCompatible Brands\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNordyne\u003c\/li\u003e\n\u003cli\u003eIntertherm\u003c\/li\u003e\n\u003cli\u003eMiller\u003c\/li\u003e\n\u003cli\u003eMAC\u003c\/li\u003e\n\u003cli\u003eBroan\u003c\/li\u003e\n\u003cli\u003eFrigidaire\u003c\/li\u003e\n\u003cli\u003eMaytag\u003c\/li\u003e\n\u003cli\u003eTappan\u003c\/li\u003e\n\u003cli\u003eWestinghouse\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eApplication\u003c\/h3\u003e\n\u003cp\u003eUsed in compatible mobile home and manufactured housing furnaces to:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eControl blower fan operation\u003c\/li\u003e\n\u003cli\u003eProvide automatic high-temperature protection\u003c\/li\u003e\n\u003cli\u003eShut down heating circuits during overheating conditions\u003c\/li\u003e\n\u003cli\u003eAutomatically start the blower when plenum temperature rises\u003c\/li\u003e\n\u003cli\u003eProtect heat exchangers and furnace components from excessive temperatures\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eRelated Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFan \u0026amp; Limit Control Assembly\u003c\/li\u003e\n\u003cli\u003eHigh-Limit Switch\u003c\/li\u003e\n\u003cli\u003eFan Switch\u003c\/li\u003e\n\u003cli\u003eBlower Relay\u003c\/li\u003e\n\u003cli\u003eFurnace Control Board\u003c\/li\u003e\n\u003cli\u003eTransformer\u003c\/li\u003e\n\u003cli\u003eBlower Motor\u003c\/li\u003e\n\u003cli\u003eThermostat\u003c\/li\u003e\n\u003cli\u003eHeat Exchanger Safety Controls\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnician Notes\u003c\/h3\u003e\n\u003cp\u003eThe original Nordyne 626291 assembly is no longer available from the manufacturer. This replacement is hand-built in our electronics shop using premium components designed to exceed OEM safety specifications. The assembly extends approximately 3 inches from the mounting plate and utilizes a 4-terminal block for direct replacement in compatible furnaces.\u003c\/p\u003e\n\u003cp\u003eCommonly found in \u003cstrong\u003eMAC 1145, 1155, and 1165 furnaces\u003c\/strong\u003e as well as older Nordyne, Intertherm, and Miller downflow mobile home furnaces. If your furnace uses the more common 3-wire connector configuration, a different replacement assembly may be required.\u003c\/p\u003e\n\u003cp\u003ePlease allow \u003cstrong\u003e24 to 48 hours for assembly prior to shipment\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eCommon Symptoms of Failure\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBlower fan will not start\u003c\/li\u003e\n\u003cli\u003eBlower fan runs continuously\u003c\/li\u003e\n\u003cli\u003eFurnace overheats and shuts down\u003c\/li\u003e\n\u003cli\u003eFrequent limit switch trips\u003c\/li\u003e\n\u003cli\u003eShort cycling\u003c\/li\u003e\n\u003cli\u003eIntermittent blower operation\u003c\/li\u003e\n\u003cli\u003eNo heat output\u003c\/li\u003e\n\u003cli\u003eExcessive furnace cabinet temperatures\u003c\/li\u003e\n\u003cli\u003eDelayed blower operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eInstallation Tips\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eDisconnect power before servicing.\u003c\/li\u003e\n\u003cli\u003eVerify your furnace uses a 4-prong combination fan and limit switch.\u003c\/li\u003e\n\u003cli\u003eLabel wires before removing the original assembly.\u003c\/li\u003e\n\u003cli\u003eConfirm switch orientation and mounting depth.\u003c\/li\u003e\n\u003cli\u003eInspect terminals for corrosion or heat damage.\u003c\/li\u003e\n\u003cli\u003eVerify blower operation through a complete heating cycle.\u003c\/li\u003e\n\u003cli\u003eConfirm proper fan-on and high-limit temperatures after installation.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003chr\u003e\n\u003ch3\u003eRecommended Inspection Items\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBlower motor amperage\u003c\/li\u003e\n\u003cli\u003eHeat exchanger condition\u003c\/li\u003e\n\u003cli\u003eAir filter restriction\u003c\/li\u003e\n\u003cli\u003eFan switch operation\u003c\/li\u003e\n\u003cli\u003eLimit switch operation\u003c\/li\u003e\n\u003cli\u003eWiring harness terminals\u003c\/li\u003e\n\u003cli\u003eFurnace temperature rise\u003c\/li\u003e\n\u003cli\u003eSupply and return airflow\u003c\/li\u003e\n\u003cli\u003eVenting system condition\u003c\/li\u003e\n\u003cli\u003eControl board connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003e\u003cspan\u003eOriginal is no longer available. You will receive a replacement unit built in our electronics shop to exceed safety specs. Fan \u0026amp; limit control. Extends 3\" out from backplate. Fan switch is rated at F110-20F. Limit switch is rated at L130-15F. Fan \u0026amp; limit cannot be bought separately. Switch size is 11T11. Base plate with 4 terminals measures 3x3-1\/8\". Replaces 6262910. This is the less-common 4-prong furnace switch.\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan\u003eFan and limit switch assembly most often found on Mac 1145, 1155 and 1165 furnaces. Contains L130F limit switch 6260251 and F110 fan switch 6260380, 626023\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eIf you only have the more common 3-wire connectors, you need to purchase the 626XXX\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable class=\"a-normal a-spacing-micro\" role=\"list\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"a-spacing-small po-operation_mode\" role=\"listitem\"\u003e\n\u003ctd class=\"a-span3\" role=\"presentation\"\u003e\u003cspan class=\"a-size-base a-text-bold\"\u003eOperation Mode\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"a-span9\" role=\"presentation\"\u003e\u003cspan class=\"a-size-base po-break-word\"\u003eautomatic\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"a-spacing-small po-contact.type\" role=\"listitem\"\u003e\n\u003ctd class=\"a-span3\" role=\"presentation\"\u003e\u003cspan class=\"a-size-base a-text-bold\"\u003eContact Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"a-span9\" role=\"presentation\"\u003e\u003cspan class=\"a-size-base po-break-word\"\u003eNormally Open\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"a-spacing-small po-connector_type\" role=\"listitem\"\u003e\n\u003ctd class=\"a-span3\" role=\"presentation\"\u003e\u003cspan class=\"a-size-base a-text-bold\"\u003eConnector Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"a-span9\" role=\"presentation\"\u003e\u003cspan class=\"a-size-base po-break-word\"\u003e3-pin\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"a-spacing-small po-brand\" role=\"listitem\"\u003e\n\u003ctd class=\"a-span3\" role=\"presentation\"\u003e\u003cspan class=\"a-size-base a-text-bold\"\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"a-span9\" role=\"presentation\"\u003e\u003cspan class=\"a-size-base po-break-word\"\u003eAberdeen Parts Store\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"a-spacing-small po-switch_type\" role=\"listitem\"\u003e\n\u003ctd class=\"a-span3\" role=\"presentation\"\u003e\u003cspan class=\"a-size-base a-text-bold\"\u003eSwitch Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"a-span9\" role=\"presentation\"\u003e\u003cspan class=\"a-size-base po-break-word\"\u003eLimit Switch\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"a-spacing-small po-terminal_type\" role=\"listitem\"\u003e\n\u003ctd class=\"a-span3\" role=\"presentation\"\u003e\u003cspan class=\"a-size-base a-text-bold\"\u003eTerminal\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"a-span9\" role=\"presentation\"\u003e\u003cspan class=\"a-size-base po-break-word\"\u003eThrough Hole\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"a-spacing-small po-material\" role=\"listitem\"\u003e\n\u003ctd class=\"a-span3\" role=\"presentation\"\u003e\u003cspan class=\"a-size-base a-text-bold\"\u003eMaterial\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"a-span9\" role=\"presentation\"\u003e\u003cspan class=\"a-size-base po-break-word\"\u003eCopper\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"a-spacing-small po-circuit_type\" role=\"listitem\"\u003e\n\u003ctd class=\"a-span3\" role=\"presentation\"\u003e\u003cspan class=\"a-size-base a-text-bold\"\u003eCircuit Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"a-span9\" role=\"presentation\"\u003e\u003cspan class=\"a-size-base po-break-word\"\u003e3-way\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"a-spacing-small po-mounting_type\" role=\"listitem\"\u003e\n\u003ctd class=\"a-span3\" role=\"presentation\"\u003e\u003cspan class=\"a-size-base a-text-bold\"\u003eMounting Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd class=\"a-span9\" role=\"presentation\"\u003e\u003cspan class=\"a-size-base po-break-word\"\u003eFlush Mount\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch1\u003e\n\u003cbr\u003e\u003cspan style=\"background-color: rgb(255, 255, 0);\"\u003e1 year warranty\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eNordyne 626291 Fan \u0026amp; Limit Control\u003c\/strong\u003e is the OEM 4‑prong combination switch used in Intertherm, Miller, and Nordyne mobile‑home furnaces. This dual snap‑disc control manages both blower activation and high‑temperature protection in one assembly.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eF110°F fan switch\u003c\/strong\u003e closes on temperature rise to start the blower, while the \u003cstrong\u003eL130°F limit switch\u003c\/strong\u003e opens on rise to protect the heat exchanger from overheating. The integrated \u003cstrong\u003e4‑terminal block\u003c\/strong\u003e matches the original Nordyne wiring harness for a direct, no‑modification replacement.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul role=\"list\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOEM Nordyne \/ Intertherm \/ Miller part\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eFan ON:\u003c\/strong\u003e 110°F\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eFan OFF:\u003c\/strong\u003e ~90°F (typical differential)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eHigh Limit:\u003c\/strong\u003e 130°F (opens on rise)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eReset:\u003c\/strong\u003e Automatic\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eTerminals:\u003c\/strong\u003e 4‑prong combination block\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e Standard snap‑disc flange\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDirect replacement for Nordyne MH furnaces\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cstrong\u003eTechnical Specs\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul role=\"list\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eTemperature Ratings:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul role=\"list\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eF110‑20F\u003c\/strong\u003e fan switch\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eL130‑40F\u003c\/strong\u003e limit switch\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eSwitch Type:\u003c\/strong\u003e Dual snap‑disc\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eAction:\u003c\/strong\u003e Fan closes on rise \/ Limit opens on rise\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eReset:\u003c\/strong\u003e Automatic\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eTerminals:\u003c\/strong\u003e 4‑prong OEM block\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e Mobile‑home furnaces (Nordyne \/ Intertherm \/ Miller)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cstrong\u003eCross‑Reference Part Numbers\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul role=\"list\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e626291\u003c\/strong\u003e — Nordyne OEM\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e6262‑91\u003c\/strong\u003e — Alternate formatting\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eIntertherm \/ Miller 626291\u003c\/strong\u003e — same part\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eF110‑20F + L130‑40F\u003c\/strong\u003e — functional temperature equivalents\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch2\u003e\u003cstrong\u003eCompatible Furnace Models\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eCommonly used in:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul role=\"list\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eNordyne \/ MAC \/ Miller mobile‑home furnaces\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eUnits using a \u003cstrong\u003esingle 4‑terminal fan\/limit disc\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOlder downflow MH furnaces with combo fan\/limit controls\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eIf your furnace has a \u003cstrong\u003e4‑prong combination snap‑disc\u003c\/strong\u003e, this is the correct replacement.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan\u003eWe build these in our electronics shop\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cspan\u003eReplaces 6260230 \u0026amp; 6260231.\u003c\/span\u003e\u003c\/p\u003e","brand":"Bower","offers":[{"title":"Default Title","offer_id":32578418475074,"sku":"626291","price":231.39,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1071\/8320\/products\/626023photo3.jpg?v=1612046027","url":"https:\/\/hvacpartstoremarket.com\/products\/626291-nordyne-mac-fan-limit-control-l130f-f110-4-prong","provider":"HVACpartstore","version":"1.0","type":"link"}