colemanhvacparts.com, www.darindevries.com

620859R Nordyne Transformer 208/240vPri 24vSec 30va

  • $ 56.48
    Unit price per 
  • Save $ 2.53
Shipping calculated at checkout.


620859R Nordyne Transformer 208/240VAC Primary 24VAC Secondary 30VA

The Nordyne 620859R is a genuine OEM 30VA control transformer designed to convert 208/240VAC line voltage into 24VAC control voltage for Nordyne, Intertherm, Miller, Broan, Frigidaire, Gibson, Maytag, and Tappan HVAC equipment.

This transformer provides the low‑voltage power required for thermostats, gas valves, contactors, relays, sequencers, control boards, and other HVAC control circuits. Manufactured to OEM specifications, the 620859R delivers reliable 24VAC output and helps ensure proper system communication and operation.

The transformer is commonly replaced when a low‑voltage short, damaged thermostat wiring, failed relay coil, or control board fault causes transformer burnout or loss of 24‑volt power.


 Cross‑Reference (Technician Binder Card Format)

Direct OEM

  • 620859R — Nordyne Control Transformer

Compatible Brands

  • Nordyne
  • Intertherm
  • Miller
  • Broan
  • Frigidaire
  • Gibson
  • Maytag
  • Tappan

Specifications

  • Primary Voltage: 208/240 VAC
  • Secondary Voltage: 24 VAC
  • VA Rating: 30 VA
  • Frequency: 50/60 Hz
  • Type: HVAC Control Transformer
  • OEM Replacement: Yes

Common Applications

  • Gas Furnaces
  • Electric Furnaces
  • Mobile Home Furnaces
  • Air Handlers
  • Package Units
  • HVAC Low‑Voltage Control Circuits

Related Components

  • 620825R — 115V/24V 20VA Transformer
  • 621898R — 30A Relay
  • Thermostats
  • Gas Valves
  • Fan Relays
  • Sequencers
  • Furnace Control Boards

 Technician Notes

  • Converts 208/240VAC supply voltage to 24VAC control voltage.
  • Supplies power for thermostat and control circuits.
  • Always locate and repair any low‑voltage short before replacing the transformer.
  • Verify proper secondary voltage under load after installation.

Common Symptoms of Failure

  • Blank thermostat display
  • No 24VAC control voltage
  • Furnace or air handler completely inoperative
  • Contactor not pulling in
  • Gas valve not energizing
  • Blown low‑voltage fuse
  • Burned transformer winding

Installation Tips

  • Disconnect power before servicing.
  • Verify incoming voltage matches transformer primary taps.
  • Check secondary voltage before reconnecting controls.
  • Inspect thermostat wiring for shorts or grounding faults.
  • Verify all connected devices are within the 30VA load capacity.