{"product_id":"58035-aerco-boiler-limit-control","title":"58035 AERCO Boiler LIMIT CONTROL","description":"\u003ch1\u003e58035 AERCO Boiler LIMIT CONTROL\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan style=\"background-color: rgb(255, 255, 0);\"\u003e\u003cstrong\u003eNormal Stock Item\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cmeta content=\"text\/html; charset=us-ascii\" http-equiv=\"Content-Type\"\u003e\u003c\/p\u003e\n\u003cstyle\u003e\na {\n    text-decoration: none;\n    color: #464feb;\n}\ntr th, tr td {\n    border: 1px solid #e6e6e6;\n}\ntr th {\n    background-color: #f5f5f5;\n}\n\u003c\/style\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe \u003cstrong\u003eAERCO 58035 Limit Control\u003c\/strong\u003e is a genuine OEM safety control designed for use in compatible AERCO commercial boilers and water heaters. This critical temperature-limiting device helps protect the heating system from unsafe operating conditions by monitoring temperature and initiating a shutdown or interrupting operation when preset limits are exceeded. By providing an added layer of safety, the 58035 Limit Control helps protect the heat exchanger, internal components, and overall system integrity.\u003c\/p\u003e\n\u003cp\u003eManufactured to AERCO's original equipment specifications, this control is designed to deliver reliable performance in demanding commercial heating and domestic hot water applications.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eCross-Reference\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e58035\u003c\/li\u003e\n\u003cli\u003eAERCO 58035\u003c\/li\u003e\n\u003cli\u003eLimit Control\u003c\/li\u003e\n\u003cli\u003eHigh Limit Control\u003c\/li\u003e\n\u003cli\u003eTemperature Safety Control\u003c\/li\u003e\n\u003cli\u003eBoiler Limit Switch\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eDirect OEM\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eYes\u003c\/strong\u003e – Genuine AERCO OEM replacement limit control.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eCompatible Brands\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eAERCO\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompatible with select:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAERCO Commercial Boilers\u003c\/li\u003e\n\u003cli\u003eAERCO Commercial Water Heaters\u003c\/li\u003e\n\u003cli\u003eAERCO Hydronic Heating Systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAlways verify compatibility using the unit model and serial number.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eApplication\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eCommercial boilers\u003c\/li\u003e\n\u003cli\u003eCommercial water heaters\u003c\/li\u003e\n\u003cli\u003eTemperature safety circuits\u003c\/li\u003e\n\u003cli\u003eOver-temperature protection systems\u003c\/li\u003e\n\u003cli\u003eHydronic heating equipment\u003c\/li\u003e\n\u003cli\u003eOEM safety control replacement\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eRelated Components\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eWater Outlet Temperature Sensors\u003c\/li\u003e\n\u003cli\u003eExhaust Temperature Sensors\u003c\/li\u003e\n\u003cli\u003eIgnition \/ Stepper Boards\u003c\/li\u003e\n\u003cli\u003eGas Valves\u003c\/li\u003e\n\u003cli\u003eFlame Sensors\u003c\/li\u003e\n\u003cli\u003eActuator Control Systems\u003c\/li\u003e\n\u003cli\u003eControl Boards\u003c\/li\u003e\n\u003cli\u003eAnnual Maintenance Kits\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnician Notes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eGenuine OEM AERCO safety control.\u003c\/li\u003e\n\u003cli\u003eDesigned to monitor system temperature and prevent overheating.\u003c\/li\u003e\n\u003cli\u003eCritical component for boiler and water heater safety.\u003c\/li\u003e\n\u003cli\u003eVerify operating temperatures before replacing the control.\u003c\/li\u003e\n\u003cli\u003eInspect associated sensors and wiring when troubleshooting limit faults.\u003c\/li\u003e\n\u003cli\u003eAlways determine the root cause of overheating before replacing a failed limit control.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eCommon Symptoms of Failure\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eBoiler lockout conditions\u003c\/li\u003e\n\u003cli\u003eOver-temperature fault codes\u003c\/li\u003e\n\u003cli\u003eIntermittent heating operation\u003c\/li\u003e\n\u003cli\u003eUnexpected shutdowns\u003c\/li\u003e\n\u003cli\u003eFailure to maintain operation\u003c\/li\u003e\n\u003cli\u003eHigh-limit trips\u003c\/li\u003e\n\u003cli\u003eSafety-related diagnostic alarms\u003c\/li\u003e\n\u003cli\u003eNo heat or hot water output\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eInstallation Tips\u003c\/h2\u003e\n\u003col\u003e\n\u003cli\u003eDisconnect electrical power before servicing.\u003c\/li\u003e\n\u003cli\u003eVerify the replacement part number matches the original control.\u003c\/li\u003e\n\u003cli\u003eInspect all wiring and terminal connections.\u003c\/li\u003e\n\u003cli\u003eInstall the control according to AERCO specifications.\u003c\/li\u003e\n\u003cli\u003eVerify mounting and sensing location.\u003c\/li\u003e\n\u003cli\u003eRestore power and clear any fault codes.\u003c\/li\u003e\n\u003cli\u003eTest system operation through a complete heating cycle.\u003c\/li\u003e\n\u003cli\u003eConfirm proper temperature regulation and safety operation.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003chr\u003e\n\u003ch2\u003eRecommended Inspection Items\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eWater outlet temperature sensor\u003c\/li\u003e\n\u003cli\u003eExhaust temperature sensor\u003c\/li\u003e\n\u003cli\u003eGas valve operation\u003c\/li\u003e\n\u003cli\u003eBurner assembly\u003c\/li\u003e\n\u003cli\u003eHeat exchanger condition\u003c\/li\u003e\n\u003cli\u003eControl board diagnostics\u003c\/li\u003e\n\u003cli\u003eWiring harness connections\u003c\/li\u003e\n\u003cli\u003eCirculation pump operation\u003c\/li\u003e\n\u003cli\u003eBoiler operating temperatures\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Neuco","offers":[{"title":"Default Title","offer_id":45167759589442,"sku":null,"price":342.12,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1071\/8320\/files\/Screenshot2026-09-06161120.png?v=1788736300","url":"https:\/\/hvacpartstoremarket.com\/products\/58035-aerco-boiler-limit-control","provider":"HVACpartstore","version":"1.0","type":"link"}