58035 AERCO Boiler LIMIT CONTROL
58035 AERCO Boiler LIMIT CONTROL
Normal Stock Item
The AERCO 58035 Limit Control is a genuine OEM safety control designed for use in compatible AERCO commercial boilers and water heaters. This critical temperature-limiting device helps protect the heating system from unsafe operating conditions by monitoring temperature and initiating a shutdown or interrupting operation when preset limits are exceeded. By providing an added layer of safety, the 58035 Limit Control helps protect the heat exchanger, internal components, and overall system integrity.
Manufactured to AERCO's original equipment specifications, this control is designed to deliver reliable performance in demanding commercial heating and domestic hot water applications.
Cross-Reference
- 58035
- AERCO 58035
- Limit Control
- High Limit Control
- Temperature Safety Control
- Boiler Limit Switch
Direct OEM
Yes – Genuine AERCO OEM replacement limit control.
Compatible Brands
- AERCO
Compatible with select:
- AERCO Commercial Boilers
- AERCO Commercial Water Heaters
- AERCO Hydronic Heating Systems
Always verify compatibility using the unit model and serial number.
Application
- Commercial boilers
- Commercial water heaters
- Temperature safety circuits
- Over-temperature protection systems
- Hydronic heating equipment
- OEM safety control replacement
Related Components
- Water Outlet Temperature Sensors
- Exhaust Temperature Sensors
- Ignition / Stepper Boards
- Gas Valves
- Flame Sensors
- Actuator Control Systems
- Control Boards
- Annual Maintenance Kits
Technician Notes
- Genuine OEM AERCO safety control.
- Designed to monitor system temperature and prevent overheating.
- Critical component for boiler and water heater safety.
- Verify operating temperatures before replacing the control.
- Inspect associated sensors and wiring when troubleshooting limit faults.
- Always determine the root cause of overheating before replacing a failed limit control.
Common Symptoms of Failure
- Boiler lockout conditions
- Over-temperature fault codes
- Intermittent heating operation
- Unexpected shutdowns
- Failure to maintain operation
- High-limit trips
- Safety-related diagnostic alarms
- No heat or hot water output
Installation Tips
- Disconnect electrical power before servicing.
- Verify the replacement part number matches the original control.
- Inspect all wiring and terminal connections.
- Install the control according to AERCO specifications.
- Verify mounting and sensing location.
- Restore power and clear any fault codes.
- Test system operation through a complete heating cycle.
- Confirm proper temperature regulation and safety operation.
Recommended Inspection Items
- Water outlet temperature sensor
- Exhaust temperature sensor
- Gas valve operation
- Burner assembly
- Heat exchanger condition
- Control board diagnostics
- Wiring harness connections
- Circulation pump operation
- Boiler operating temperatures