S1-3112-3571 Coleman 3-pole sequencer H1-110 C1-110
S1-3112-3571 Coleman 3-pole sequencer H1-110 C1-110,
The S1-3112-3571 3-Pole Sequencer is a genuine OEM Coleman electric furnace control designed to sequence electric heat strips and blower operation during heating cycles. This heating sequencer features H1-110 and C1-110 timing characteristics, providing controlled staging of electric heating elements to reduce electrical load surges and ensure efficient furnace operation. Commonly used in Coleman, York, Evcon, and other manufactured housing electric furnaces, this sequencer helps maintain reliable heat delivery and proper system performance.
Cross‑Reference
- S1-3112-3571
- 3112-3571
- S131123571
- H1-110
- C1-110
- Coleman Sequencer
- York Sequencer
- Electric Furnace Sequencer
Direct OEM
Yes, Genuine OEM Coleman / York replacement sequencer.
Compatible Brands
- Coleman
- York
- Evcon
- Luxaire
- Fraser-Johnston
Verify model and serial number compatibility before ordering.
Application
- Electric Furnaces
- Electric Heat Strip Systems
- Manufactured Housing Furnaces
- Electric Air Handlers
- Multi-Stage Electric Heating Systems
Specifications
- Type: Electric Heat Sequencer
- Poles: 3
- Timing Code: H1-110 / C1-110
- Function: Heat Strip Staging Control
- OEM Replacement Component
Related Components
- Heating Elements
- Heat Strips
- Limit Switches
- Blower Motors
- Fan Relays
- Control Boards
- Contactor Assemblies
- Wiring Harnesses
- Terminal Blocks
Technician Notes
- Sequencers control the timed energizing and de-energizing of electric heating elements.
- A failed sequencer can cause loss of heat, reduced heat output, or continuous heating operation.
- Always inspect heat strips and limit switches when replacing a sequencer.
- Verify all terminals are tight and free from heat damage.
- Compare timing and terminal configuration before installation.
Common Symptoms of Failure
- No Heat
- Partial Heat Output
- Heat Strips Not Energizing
- Continuous Heating Operation
- Blower Runs Without Heat
- Uneven Heat Staging
- Furnace Trips High Limits
- Burned or Damaged Terminals
- Intermittent Electric Heat
Installation Tips
- Disconnect electrical power to the furnace.
- Label all wires before removal.
- Verify replacement timing and pole configuration.
- Remove the defective sequencer.
- Transfer wiring one terminal at a time.
- Secure the new sequencer firmly.
- Inspect surrounding wiring for heat damage.
- Restore power and verify proper heat staging.
- Confirm all heating elements cycle correctly.
Recommended Inspection Items
- Heating Elements
- Limit Switches
- Blower Motor
- Blower Wheel
- Electrical Connections
- Terminal Blocks
- Heat Strip Wiring
- Fan Relay
- Control Board
- Supply Voltage
Replaces 3400-357 & 3112-357. H1-110, C1-110. 3112-3571