{"product_id":"29700-aerco-boiler-ignitor","title":"29700 AERCO Boiler IGNITOR","description":"\u003ch1\u003e29700 AERCO Boiler IGNITOR\u003c\/h1\u003e\n\u003cp\u003e\u003cspan style=\"background-color: rgb(255, 255, 0);\"\u003e\u003cb\u003e\u003cspan style=\"font-size: large; background-color: rgb(255, 255, 0);\"\u003eNormal Stocking Item in Our Warehouse \u003c\/span\u003e\u003c\/b\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cmeta content=\"text\/html; charset=us-ascii\" http-equiv=\"Content-Type\"\u003e\u003c\/p\u003e\n\u003cstyle\u003e\na {\n    text-decoration: none;\n    color: #464feb;\n}\ntr th, tr td {\n    border: 1px solid #e6e6e6;\n}\ntr th {\n    background-color: #f5f5f5;\n}\n\u003c\/style\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe \u003cstrong\u003e29700 AERCO Ignitor\u003c\/strong\u003e is a genuine OEM replacement ignition component designed for use in compatible AERCO commercial boilers. This critical burner ignition device generates the spark required to ignite the fuel-air mixture during the startup sequence, ensuring reliable boiler operation and efficient combustion performance. Manufactured to AERCO factory specifications, the 29700 ignitor is engineered to provide dependable ignition in demanding commercial heating applications.\u003c\/p\u003e\n\u003cp\u003eAs a direct OEM replacement, the 29700 ignitor helps restore proper burner startup, reduce ignition failures, and maintain safe and efficient boiler operation.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eCross-Reference\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e29700\u003c\/li\u003e\n\u003cli\u003eAERCO 29700\u003c\/li\u003e\n\u003cli\u003eIgnitor\u003c\/li\u003e\n\u003cli\u003eSpark Ignitor\u003c\/li\u003e\n\u003cli\u003eIgnition Electrode\u003c\/li\u003e\n\u003cli\u003eBoiler Ignitor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eDirect OEM\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eYes\u003c\/strong\u003e – Genuine AERCO OEM replacement ignitor.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eCompatible Brands\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eAERCO\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompatible with select:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAERCO Commercial Boilers\u003c\/li\u003e\n\u003cli\u003eAERCO Benchmark Boilers\u003c\/li\u003e\n\u003cli\u003eAERCO High-Efficiency Boiler Systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAlways verify compatibility using the boiler model and serial number before ordering.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eApplication\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eCommercial boiler ignition systems\u003c\/li\u003e\n\u003cli\u003eBurner ignition assemblies\u003c\/li\u003e\n\u003cli\u003eSpark ignition applications\u003c\/li\u003e\n\u003cli\u003eCombustion control systems\u003c\/li\u003e\n\u003cli\u003eBoiler maintenance and repairs\u003c\/li\u003e\n\u003cli\u003eOEM replacement service\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eRelated Components\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e65085 Ignition Transformer\u003c\/li\u003e\n\u003cli\u003e65104 High Voltage Ignition Cable\u003c\/li\u003e\n\u003cli\u003e65182 Flame Rod\u003c\/li\u003e\n\u003cli\u003e95251246 Flame Detector\u003c\/li\u003e\n\u003cli\u003eGM-123428 Flame Detector Assembly\u003c\/li\u003e\n\u003cli\u003e58084 Ignitor Rod Replacement Kit\u003c\/li\u003e\n\u003cli\u003eIgnition \/ Stepper Boards\u003c\/li\u003e\n\u003cli\u003eBurner Assemblies\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnician Notes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eGenuine OEM AERCO ignition component.\u003c\/li\u003e\n\u003cli\u003eProduces the spark necessary for burner startup.\u003c\/li\u003e\n\u003cli\u003eCritical for reliable boiler ignition and safe operation.\u003c\/li\u003e\n\u003cli\u003eInspect ignition cables and connectors when replacing the ignitor.\u003c\/li\u003e\n\u003cli\u003eVerify proper ignitor positioning and electrode gap according to AERCO specifications.\u003c\/li\u003e\n\u003cli\u003eCheck flame-sensing components and ignition controls during service.\u003c\/li\u003e\n\u003cli\u003eRecommended replacement if the ignitor shows cracking, excessive wear, contamination, or weak spark output.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eCommon Symptoms of Failure\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eBoiler will not ignite\u003c\/li\u003e\n\u003cli\u003eIgnition lockout faults\u003c\/li\u003e\n\u003cli\u003eDelayed ignition\u003c\/li\u003e\n\u003cli\u003eNo spark during startup\u003c\/li\u003e\n\u003cli\u003eRepeated ignition attempts\u003c\/li\u003e\n\u003cli\u003eLoss of heat production\u003c\/li\u003e\n\u003cli\u003eIntermittent burner operation\u003c\/li\u003e\n\u003cli\u003eIgnition-related fault codes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eInstallation Tips\u003c\/h2\u003e\n\u003col\u003e\n\u003cli\u003eDisconnect electrical power before servicing.\u003c\/li\u003e\n\u003cli\u003eVerify replacement part number compatibility.\u003c\/li\u003e\n\u003cli\u003eInspect ignition wiring and terminals.\u003c\/li\u003e\n\u003cli\u003eRemove the old ignitor carefully to avoid damage to surrounding components.\u003c\/li\u003e\n\u003cli\u003eInstall the replacement ignitor in the original mounting position.\u003c\/li\u003e\n\u003cli\u003eVerify all connections are secure.\u003c\/li\u003e\n\u003cli\u003eRestore power and test the ignition sequence.\u003c\/li\u003e\n\u003cli\u003eConfirm reliable burner ignition and stable operation.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003chr\u003e\n\u003ch2\u003eRecommended Inspection Items\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eHigh voltage ignition cable\u003c\/li\u003e\n\u003cli\u003eIgnition transformer\u003c\/li\u003e\n\u003cli\u003eFlame rod condition\u003c\/li\u003e\n\u003cli\u003eFlame detector assembly\u003c\/li\u003e\n\u003cli\u003eBurner assembly\u003c\/li\u003e\n\u003cli\u003eGas valve operation\u003c\/li\u003e\n\u003cli\u003eCombustion blower performance\u003c\/li\u003e\n\u003cli\u003eControl board diagnostics\u003c\/li\u003e\n\u003cli\u003eVenting system condition\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Neuco","offers":[{"title":"Default Title","offer_id":42447238234178,"sku":"29700","price":1620.43,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1071\/8320\/files\/Screenshot2025-12-19095241.png?v=1766163194","url":"https:\/\/hvacpartstoremarket.com\/products\/29700-aerco-boiler-ignitor","provider":"HVACpartstore","version":"1.0","type":"link"}