27128-2 AERCO Boiler GAS PRESSURE SWITCH KIT
27128-2 AERCO Boiler GAS PRESSURE SWITCH KIT
Normal Stock Item
Replaces Part Number 61002-11
The 27128-2 AERCO Gas Pressure Switch Kit is a genuine OEM replacement safety component designed for use in compatible AERCO commercial boilers. This gas pressure switch monitors fuel gas pressure within the heating system and provides critical safety verification to the boiler control system. By confirming proper gas supply conditions, the switch helps ensure safe ignition, reliable combustion performance, and protection against unsafe operating conditions caused by inadequate or abnormal gas pressure.
Engineered to AERCO factory specifications, the 27128-2 Gas Pressure Switch Kit provides dependable performance and is an essential component in maintaining safe and efficient boiler operation.
Normal Stock Item
Cross-Reference
- 27128-2
- 271282
- AERCO 27128-2
- Gas Pressure Switch Kit
- Fuel Gas Pressure Switch
- Boiler Pressure Switch
Direct OEM
Yes – Genuine AERCO OEM replacement gas pressure switch kit.
Compatible Brands
- AERCO
Compatible with select:
- AERCO Commercial Boilers
- AERCO High-Efficiency Boiler Systems
- AERCO Hydronic Heating Equipment
Always verify compatibility using the boiler model and serial number.
Application
- Commercial boiler systems
- Gas-fired heating equipment
- Fuel gas monitoring systems
- Combustion safety circuits
- Boiler ignition verification systems
- OEM replacement and maintenance
Related Components
- Gas Valves
- Ignition / Stepper Boards
- Flame Detectors
- Spark Igniters
- Limit Controls
- Water Outlet Temperature Sensors
- Exhaust Temperature Sensors
- Annual Maintenance Kits
Technician Notes
- Genuine OEM AERCO safety component.
- Monitors gas pressure for safe boiler operation.
- Helps prevent ignition and combustion issues caused by insufficient gas supply.
- Verify gas pressure specifications before replacement.
- Inspect tubing, fittings, and wiring connections during service.
- Always investigate the source of pressure-related faults before replacing the switch.
Common Symptoms of Failure
- Gas pressure fault codes
- Boiler lockout conditions
- Failure to ignite
- Intermittent burner operation
- Nuisance safety shutdowns
- Delayed ignition
- Loss of heat output
- Combustion safety alarms
Installation Tips
- Disconnect electrical power before servicing.
- Shut off the gas supply if required.
- Verify the replacement switch matches the original specifications.
- Inspect pressure tubing for cracks, leaks, or blockages.
- Install the switch securely and reconnect wiring.
- Confirm all tubing connections are properly seated.
- Restore power and gas supply.
- Verify proper operation and clear any diagnostic fault codes.
Recommended Inspection Items
- Gas valve operation
- Gas supply pressure
- Pressure sensing tubing
- Burner assembly
- Flame detector
- Spark igniter
- Ignition controls
- Control board diagnostics
- Venting and combustion system condition