{"product_id":"1f89-0211-copeland-comfort-control-white-rodgers-2h-1c-non-prog-ht-pmp-24v-2-blue","title":"1F89-0211 Copeland Comfort Control (White Rodgers) 2H\/1C NON PROG HT PMP 24V 2\" BLUE","description":"\u003ch1\u003e1F89-0211 Copeland Comfort Control (White Rodgers) 2H\/1C NONPROG HT PMP 24V 2\"BLUE\u003c\/h1\u003e\n\u003cstyle\u003e\na {\n    text-decoration: none;\n    color: #464feb;\n}\ntr th, tr td {\n    border: 1px solid #e6e6e6;\n}\ntr th {\n    background-color: #f5f5f5;\n}\n\u003c\/style\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe \u003cstrong\u003e1F89-0211 Copeland Comfort Control \/ White-Rodgers Thermostat\u003c\/strong\u003e is a reliable \u003cstrong\u003enon-programmable heat pump thermostat\u003c\/strong\u003e designed for residential and light commercial HVAC systems. Featuring \u003cstrong\u003e2 Heat \/ 1 Cool heat pump compatibility\u003c\/strong\u003e, \u003cstrong\u003e24-volt operation\u003c\/strong\u003e, and an easy-to-read \u003cstrong\u003e2-inch blue display\u003c\/strong\u003e, this thermostat delivers simple temperature control without complicated scheduling. Ideal for homeowners and technicians seeking dependable day-to-day comfort and straightforward operation.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eCross-Reference\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWhite-Rodgers 1F89-0211\u003c\/li\u003e\n\u003cli\u003eCopeland Comfort Control 1F89-0211\u003c\/li\u003e\n\u003cli\u003eEmerson 1F89-0211\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eDirect OEM\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCopeland Comfort Control\u003c\/li\u003e\n\u003cli\u003eWhite-Rodgers\u003c\/li\u003e\n\u003cli\u003eEmerson\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eCompatible Brands\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eColeman\u003c\/li\u003e\n\u003cli\u003eEvcon\u003c\/li\u003e\n\u003cli\u003eYork\u003c\/li\u003e\n\u003cli\u003eLuxaire\u003c\/li\u003e\n\u003cli\u003eFraser-Johnston\u003c\/li\u003e\n\u003cli\u003eGoodman\u003c\/li\u003e\n\u003cli\u003eAmana\u003c\/li\u003e\n\u003cli\u003eRheem\u003c\/li\u003e\n\u003cli\u003eRuud\u003c\/li\u003e\n\u003cli\u003eCarrier\u003c\/li\u003e\n\u003cli\u003eBryant\u003c\/li\u003e\n\u003cli\u003ePayne\u003c\/li\u003e\n\u003cli\u003eTrane\u003c\/li\u003e\n\u003cli\u003eAmerican Standard\u003c\/li\u003e\n\u003cli\u003eLennox\u003c\/li\u003e\n\u003cli\u003eHeil\u003c\/li\u003e\n\u003cli\u003eTempstar\u003c\/li\u003e\n\u003cli\u003eArmstrong Air\u003c\/li\u003e\n\u003cli\u003eMost 24V Heat Pump Systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eApplication\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eResidential heat pump systems\u003c\/li\u003e\n\u003cli\u003e2 Heat \/ 1 Cool heat pump equipment\u003c\/li\u003e\n\u003cli\u003eHome comfort control\u003c\/li\u003e\n\u003cli\u003eHVAC retrofit projects\u003c\/li\u003e\n\u003cli\u003eThermostat replacements\u003c\/li\u003e\n\u003cli\u003eResidential heating and cooling systems\u003c\/li\u003e\n\u003cli\u003eLight commercial HVAC applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eRelated Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHeat pump control boards\u003c\/li\u003e\n\u003cli\u003eOutdoor thermostats\u003c\/li\u003e\n\u003cli\u003eHeat pump contactors\u003c\/li\u003e\n\u003cli\u003eTransformers\u003c\/li\u003e\n\u003cli\u003eAir handlers\u003c\/li\u003e\n\u003cli\u003eFan relays\u003c\/li\u003e\n\u003cli\u003eDefrost controls\u003c\/li\u003e\n\u003cli\u003eThermostat wire\u003c\/li\u003e\n\u003cli\u003eIndoor temperature sensors\u003c\/li\u003e\n\u003cli\u003eFurnace and air handler controls\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnician Notes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned for \u003cstrong\u003e2 Heat \/ 1 Cool\u003c\/strong\u003e heat pump applications.\u003c\/li\u003e\n\u003cli\u003eOperates on standard \u003cstrong\u003e24 VAC HVAC control circuits\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eNon-programmable design offers simple operation and reduced setup time.\u003c\/li\u003e\n\u003cli\u003eBlue backlit display improves visibility in low-light conditions.\u003c\/li\u003e\n\u003cli\u003eSuitable for replacing many conventional heat pump thermostats.\u003c\/li\u003e\n\u003cli\u003eVerify system staging requirements before installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eCommon Symptoms of Failure\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBlank display\u003c\/li\u003e\n\u003cli\u003eIncorrect temperature readings\u003c\/li\u003e\n\u003cli\u003eHeat pump not responding\u003c\/li\u003e\n\u003cli\u003eNo heating or cooling operation\u003c\/li\u003e\n\u003cli\u003eFan operation issues\u003c\/li\u003e\n\u003cli\u003eDisplay fading or flickering\u003c\/li\u003e\n\u003cli\u003eThermostat not maintaining setpoint\u003c\/li\u003e\n\u003cli\u003eIntermittent HVAC equipment operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eInstallation Tips\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eDisconnect HVAC power before installation.\u003c\/li\u003e\n\u003cli\u003eLabel existing thermostat wires prior to removal.\u003c\/li\u003e\n\u003cli\u003eVerify compatibility with 2H\/1C heat pump systems.\u003c\/li\u003e\n\u003cli\u003eEnsure proper wiring to terminals.\u003c\/li\u003e\n\u003cli\u003eMount on an interior wall away from drafts and direct sunlight.\u003c\/li\u003e\n\u003cli\u003eCheck thermostat leveling if required.\u003c\/li\u003e\n\u003cli\u003eTest heating, cooling, and fan functions after installation.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003chr\u003e\n\u003ch3\u003eRecommended Inspection Items\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThermostat wiring connections\u003c\/li\u003e\n\u003cli\u003eTransformer output voltage\u003c\/li\u003e\n\u003cli\u003eAir handler operation\u003c\/li\u003e\n\u003cli\u003eHeat pump reversing valve operation\u003c\/li\u003e\n\u003cli\u003eControl board status\u003c\/li\u003e\n\u003cli\u003eIndoor temperature accuracy\u003c\/li\u003e\n\u003cli\u003eFan operation\u003c\/li\u003e\n\u003cli\u003eElectrical terminal condition\u003c\/li\u003e\n\u003cli\u003eBattery compartment (if applicable)\u003c\/li\u003e\n\u003cli\u003eHVAC system staging performance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Quinn","offers":[{"title":"Default Title","offer_id":45892529160258,"sku":"60-1F89-0211","price":81.42,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1071\/8320\/files\/Screenshot2026-11-03221406.png?v=1793769297","url":"https:\/\/hvacpartstoremarket.com\/products\/1f89-0211-copeland-comfort-control-white-rodgers-2h-1c-non-prog-ht-pmp-24v-2-blue","provider":"HVACpartstore","version":"1.0","type":"link"}