{"product_id":"1f86-0244-copeland-comfort-control-white-rodgers-1ht-1cl-non-prog-24v-45-90","title":"1F86-0244 Copeland Comfort Control (White Rodgers) 1HT\/1CL NON PROG 24V 45-90","description":"\u003ch1\u003e1F86-0244 Copeland Comfort Control (White Rodgers) 1HT\/1CL NON PROG 24V 45-90\u003c\/h1\u003e\n\u003cp\u003eIn stock \u003c\/p\u003e\n\u003cstyle\u003e\na {\n    text-decoration: none;\n    color: #464feb;\n}\ntr th, tr td {\n    border: 1px solid #e6e6e6;\n}\ntr th {\n    background-color: #f5f5f5;\n}\n\u003c\/style\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe \u003cstrong\u003e1F86-0244 Copeland Comfort Control \/ White-Rodgers Thermostat\u003c\/strong\u003e is a dependable \u003cstrong\u003enon-programmable 24V thermostat\u003c\/strong\u003e designed for conventional \u003cstrong\u003e1 Heat \/ 1 Cool HVAC systems\u003c\/strong\u003e. Featuring an easy-to-read digital display and a temperature control range of \u003cstrong\u003e45°F to 90°F\u003c\/strong\u003e, this thermostat provides straightforward operation for homeowners and service technicians alike. Its simple design makes it an ideal replacement thermostat for residential furnaces, air conditioners, and package units requiring reliable temperature control without programming features.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eCross-Reference\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWhite-Rodgers 1F86-0244\u003c\/li\u003e\n\u003cli\u003eCopeland Comfort Control 1F86-0244\u003c\/li\u003e\n\u003cli\u003eEmerson 1F86-0244\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eDirect OEM\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCopeland Comfort Control\u003c\/li\u003e\n\u003cli\u003eWhite-Rodgers\u003c\/li\u003e\n\u003cli\u003eEmerson\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eCompatible Brands\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eColeman\u003c\/li\u003e\n\u003cli\u003eEvcon\u003c\/li\u003e\n\u003cli\u003eYork\u003c\/li\u003e\n\u003cli\u003eLuxaire\u003c\/li\u003e\n\u003cli\u003eFraser-Johnston\u003c\/li\u003e\n\u003cli\u003eGoodman\u003c\/li\u003e\n\u003cli\u003eAmana\u003c\/li\u003e\n\u003cli\u003eRheem\u003c\/li\u003e\n\u003cli\u003eRuud\u003c\/li\u003e\n\u003cli\u003eCarrier\u003c\/li\u003e\n\u003cli\u003eBryant\u003c\/li\u003e\n\u003cli\u003ePayne\u003c\/li\u003e\n\u003cli\u003eTrane\u003c\/li\u003e\n\u003cli\u003eAmerican Standard\u003c\/li\u003e\n\u003cli\u003eLennox\u003c\/li\u003e\n\u003cli\u003eHeil\u003c\/li\u003e\n\u003cli\u003eTempstar\u003c\/li\u003e\n\u003cli\u003eArmstrong Air\u003c\/li\u003e\n\u003cli\u003eMost 24V conventional HVAC systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eApplication\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 Heat \/ 1 Cool systems\u003c\/li\u003e\n\u003cli\u003eGas furnace systems\u003c\/li\u003e\n\u003cli\u003eElectric furnace systems\u003c\/li\u003e\n\u003cli\u003eAir conditioning systems\u003c\/li\u003e\n\u003cli\u003eResidential HVAC replacements\u003c\/li\u003e\n\u003cli\u003ePackage units\u003c\/li\u003e\n\u003cli\u003eConventional heating and cooling equipment\u003c\/li\u003e\n\u003cli\u003eLight commercial HVAC applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eRelated Components\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eControl transformers\u003c\/li\u003e\n\u003cli\u003eThermostat wire\u003c\/li\u003e\n\u003cli\u003eFurnace control boards\u003c\/li\u003e\n\u003cli\u003eContactors\u003c\/li\u003e\n\u003cli\u003eFan relays\u003c\/li\u003e\n\u003cli\u003eLimit switches\u003c\/li\u003e\n\u003cli\u003eAir handlers\u003c\/li\u003e\n\u003cli\u003eCondensing units\u003c\/li\u003e\n\u003cli\u003eIndoor temperature sensors\u003c\/li\u003e\n\u003cli\u003eHVAC control modules\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnician Notes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSupports conventional \u003cstrong\u003e1 Heat \/ 1 Cool\u003c\/strong\u003e system configurations.\u003c\/li\u003e\n\u003cli\u003eOperates on standard \u003cstrong\u003e24 VAC control circuits\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eNon-programmable design simplifies installation and operation.\u003c\/li\u003e\n\u003cli\u003eAdjustable temperature range from \u003cstrong\u003e45°F to 90°F\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eExcellent replacement option for aging mercury and mechanical thermostats.\u003c\/li\u003e\n\u003cli\u003eVerify system type before installation, as this model is not intended for multi-stage or heat pump applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eCommon Symptoms of Failure\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBlank display\u003c\/li\u003e\n\u003cli\u003eNo call for heating\u003c\/li\u003e\n\u003cli\u003eNo call for cooling\u003c\/li\u003e\n\u003cli\u003eIncorrect room temperature readings\u003c\/li\u003e\n\u003cli\u003eShort cycling equipment\u003c\/li\u003e\n\u003cli\u003eFan not responding\u003c\/li\u003e\n\u003cli\u003eIntermittent system operation\u003c\/li\u003e\n\u003cli\u003eInaccurate setpoint control\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eInstallation Tips\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eDisconnect HVAC power before installation.\u003c\/li\u003e\n\u003cli\u003eLabel existing thermostat wires before removal.\u003c\/li\u003e\n\u003cli\u003eVerify compatibility with 24V 1H\/1C systems.\u003c\/li\u003e\n\u003cli\u003eMount on an interior wall away from drafts and direct sunlight.\u003c\/li\u003e\n\u003cli\u003eEnsure secure wire terminal connections.\u003c\/li\u003e\n\u003cli\u003eConfirm proper thermostat leveling if required.\u003c\/li\u003e\n\u003cli\u003eTest heating, cooling, and fan operation after installation.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003chr\u003e\n\u003ch3\u003eRecommended Inspection Items\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThermostat wiring condition\u003c\/li\u003e\n\u003cli\u003eTransformer output voltage\u003c\/li\u003e\n\u003cli\u003eFurnace control board operation\u003c\/li\u003e\n\u003cli\u003eAir conditioner contactor operation\u003c\/li\u003e\n\u003cli\u003eIndoor temperature accuracy\u003c\/li\u003e\n\u003cli\u003eFan relay operation\u003c\/li\u003e\n\u003cli\u003eTerminal tightness\u003c\/li\u003e\n\u003cli\u003eSystem voltage readings\u003c\/li\u003e\n\u003cli\u003eHVAC equipment response\u003c\/li\u003e\n\u003cli\u003eAir filter condition\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Quinn","offers":[{"title":"Default Title","offer_id":45892930207810,"sku":"60-1F86-0244","price":72.45,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1071\/8320\/files\/Screenshot2026-11-03225244.png?v=1793771579","url":"https:\/\/hvacpartstoremarket.com\/products\/1f86-0244-copeland-comfort-control-white-rodgers-1ht-1cl-non-prog-24v-45-90","provider":"HVACpartstore","version":"1.0","type":"link"}