18557-2 AERCO Boiler and Water Heater -20/240F REV ACT REMOTE BULB
18557-2 AERCO Boiler and Water Heater -20/240F REV ACT REMOTE BULB
Normal Stocking Item in Our Warehouse
The 18557-2 AERCO Reverse Acting Remote Bulb Thermostat is a genuine OEM temperature control device designed for use in compatible AERCO commercial boilers and water heaters. Featuring a -20°F to 240°F operating range, this remote bulb thermostat utilizes a capillary tube and remote sensing bulb to monitor system temperatures and provide precise control of heating equipment operation. The reverse-acting design allows the control to respond appropriately to changing temperature conditions in specialized commercial heating and hot water applications.
Manufactured to AERCO factory specifications, the 18557-2 thermostat helps maintain accurate temperature regulation, reliable equipment performance, and safe operation in demanding commercial environments.
Cross-Reference
- 18557-2
- 185572
- AERCO 18557-2
- RA-20/240
- Reverse Acting Thermostat
- Remote Bulb Thermostat
- Temperature Control Thermostat
Direct OEM
Yes – Genuine AERCO OEM replacement thermostat.
Compatible Brands
- AERCO
Compatible with select:
- AERCO Commercial Boilers
- AERCO Commercial Water Heaters
- AERCO Hydronic Heating Systems
- AERCO Temperature Control Applications
Always verify compatibility using the equipment model and serial number before ordering.
Application
- Commercial boiler temperature control
- Commercial water heater temperature control
- Hydronic heating systems
- Remote temperature sensing
- Process temperature regulation
- OEM control replacements
Related Components
- 18557-1 Pneumatic Bulb Thermostat
- 61030 Water Outlet Temperature Sensor
- 61024 Air Inlet Temperature Sensor
- 123449 Exhaust Temperature Sensor
- 64088 Digital Limit Control
- 123966 Over Temperature Switch
- Control Boards
- Temperature Safety Controls
Technician Notes
- Genuine OEM AERCO temperature control device.
- Reverse-acting thermostat design.
- Temperature range: -20°F to 240°F.
- Remote sensing bulb configuration.
- Ideal for applications requiring remote temperature monitoring and control.
- Avoid kinking or damaging the capillary tube during installation.
- Verify sensing bulb placement is consistent with OEM specifications.
- Inspect associated control circuits when troubleshooting temperature-related issues.
Common Symptoms of Failure
- Inaccurate temperature regulation
- Failure to maintain temperature setpoint
- Boiler operating temperature fluctuations
- Water heater temperature instability
- Unexpected cycling
- Control-related faults
- Overheating or underheating conditions
- Erratic system operation
Installation Tips
- Disconnect power before servicing.
- Verify thermostat specifications match the original component.
- Carefully remove the existing sensing bulb assembly.
- Avoid bends or damage to the capillary tubing.
- Install the sensing bulb in the factory location.
- Secure all mounting and control connections.
- Restore power and verify temperature response.
- Test operation through a complete heating cycle.
Recommended Inspection Items
- Remote sensing bulb condition
- Capillary tubing integrity
- Water outlet temperature sensor
- Limit controls
- Over-temperature switch
- Control board operation
- Gas valve function
- Wiring connections
- System operating temperatures