{"product_id":"18557-1-aerco-boiler-and-water-heater-pneumatic-bulb-tstat-ra-20-240","title":"18557-1  AERCO Boiler and Water Heater Pneumatic Bulb TSTAT RA-20\/240","description":"\u003ch2\u003e18557-1 AERCO Boiler and Water Heater Pneumatic Bulb TSTAT RA-20\/240\u003c\/h2\u003e\n\u003cp\u003e\u003cb\u003e\u003cspan style=\"font-size: large;\"\u003e\u003cspan style=\"background-color: rgb(255, 255, 0);\"\u003eNormal Stocking Item in Our Warehouse\u003c\/span\u003e \u003c\/span\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cmeta content=\"text\/html; charset=us-ascii\" http-equiv=\"Content-Type\"\u003e\u003c\/p\u003e\n\u003cstyle\u003e\na {\n    text-decoration: none;\n    color: #464feb;\n}\ntr th, tr td {\n    border: 1px solid #e6e6e6;\n}\ntr th {\n    background-color: #f5f5f5;\n}\n\u003c\/style\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe \u003cstrong\u003e18557-1 AERCO Pneumatic Bulb Thermostat RA-20\/240\u003c\/strong\u003e is a genuine OEM temperature control device designed for use in compatible AERCO commercial boilers and water heaters. This pneumatic bulb thermostat monitors system temperature and provides reliable temperature regulation to help maintain proper operating conditions within the heating system. Designed to AERCO specifications, the RA-20\/240 thermostat is a critical component for maintaining temperature control, system efficiency, and safe operation in commercial heating and hot water applications.\u003c\/p\u003e\n\u003cp\u003eThe 18557-1 thermostat is engineered for dependable performance in demanding boiler room environments and is ideal for replacing worn, damaged, or malfunctioning original controls.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eCross-Reference\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e18557-1\u003c\/li\u003e\n\u003cli\u003e185571\u003c\/li\u003e\n\u003cli\u003eAERCO 18557-1\u003c\/li\u003e\n\u003cli\u003eRA-20\/240\u003c\/li\u003e\n\u003cli\u003ePneumatic Bulb Thermostat\u003c\/li\u003e\n\u003cli\u003eTemperature Control Thermostat\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eDirect OEM\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eYes\u003c\/strong\u003e – Genuine AERCO OEM replacement thermostat.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eCompatible Brands\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eAERCO\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompatible with select:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAERCO Commercial Boilers\u003c\/li\u003e\n\u003cli\u003eAERCO Commercial Water Heaters\u003c\/li\u003e\n\u003cli\u003eAERCO Hydronic Heating Systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAlways verify compatibility using the equipment model and serial number before ordering.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eApplication\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eCommercial boiler systems\u003c\/li\u003e\n\u003cli\u003eCommercial water heaters\u003c\/li\u003e\n\u003cli\u003eHydronic heating applications\u003c\/li\u003e\n\u003cli\u003eTemperature control circuits\u003c\/li\u003e\n\u003cli\u003eBoiler regulation systems\u003c\/li\u003e\n\u003cli\u003eOEM control replacements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eRelated Components\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eWater Outlet Temperature Sensors\u003c\/li\u003e\n\u003cli\u003eLimit Controls\u003c\/li\u003e\n\u003cli\u003eFlame Detectors\u003c\/li\u003e\n\u003cli\u003eIgnition \/ Stepper Boards\u003c\/li\u003e\n\u003cli\u003eGas Valves\u003c\/li\u003e\n\u003cli\u003eControl Modules\u003c\/li\u003e\n\u003cli\u003eExhaust Temperature Sensors\u003c\/li\u003e\n\u003cli\u003eAnnual Maintenance Kits\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnician Notes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eGenuine OEM AERCO temperature control device.\u003c\/li\u003e\n\u003cli\u003ePneumatic bulb sensing design.\u003c\/li\u003e\n\u003cli\u003eProvides temperature regulation for boiler and water heater operation.\u003c\/li\u003e\n\u003cli\u003eVerify capillary tube and sensing bulb condition during inspection.\u003c\/li\u003e\n\u003cli\u003eAvoid kinking or damaging the sensing bulb assembly during installation.\u003c\/li\u003e\n\u003cli\u003eInspect associated control wiring and temperature controls if troubleshooting system temperature issues.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eCommon Symptoms of Failure\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eInaccurate temperature regulation\u003c\/li\u003e\n\u003cli\u003eBoiler operating temperature fluctuations\u003c\/li\u003e\n\u003cli\u003eFailure to maintain temperature setpoint\u003c\/li\u003e\n\u003cli\u003eUnexpected cycling\u003c\/li\u003e\n\u003cli\u003eNo heat or low-temperature conditions\u003c\/li\u003e\n\u003cli\u003eOverheating concerns\u003c\/li\u003e\n\u003cli\u003eControl-related fault conditions\u003c\/li\u003e\n\u003cli\u003eErratic system operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eInstallation Tips\u003c\/h2\u003e\n\u003col\u003e\n\u003cli\u003eDisconnect power before servicing.\u003c\/li\u003e\n\u003cli\u003eVerify replacement thermostat matches the original specification.\u003c\/li\u003e\n\u003cli\u003eCarefully remove the existing sensing bulb and thermostat assembly.\u003c\/li\u003e\n\u003cli\u003eAvoid sharp bends in capillary tubing.\u003c\/li\u003e\n\u003cli\u003eInstall the sensing bulb in the original location.\u003c\/li\u003e\n\u003cli\u003eSecure all mounting hardware and connections.\u003c\/li\u003e\n\u003cli\u003eRestore power and verify temperature operation.\u003c\/li\u003e\n\u003cli\u003eMonitor system performance through a complete operating cycle.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003chr\u003e\n\u003ch2\u003eRecommended Inspection Items\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSensing bulb condition\u003c\/li\u003e\n\u003cli\u003eCapillary tubing\u003c\/li\u003e\n\u003cli\u003eWater outlet temperature sensor\u003c\/li\u003e\n\u003cli\u003eLimit controls\u003c\/li\u003e\n\u003cli\u003eBoiler control board\u003c\/li\u003e\n\u003cli\u003eGas valve operation\u003c\/li\u003e\n\u003cli\u003eWiring connections\u003c\/li\u003e\n\u003cli\u003eHeat exchanger condition\u003c\/li\u003e\n\u003cli\u003eSystem operating temperatures\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Neuco","offers":[{"title":"Default Title","offer_id":45558655418434,"sku":"18557-1","price":4911.4,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1071\/8320\/files\/Pic_large_986576e4-79bc-41f4-b78d-30ed0e8d3b46.webp?v=1739516663","url":"https:\/\/hvacpartstoremarket.com\/products\/18557-1-aerco-boiler-and-water-heater-pneumatic-bulb-tstat-ra-20-240","provider":"HVACpartstore","version":"1.0","type":"link"}