{"product_id":"1751-018-ng-gas-valve-conversion-kit-robertshaw-7100-7200","title":"1751-018 NG gas valve conversion kit Robertshaw 7100 7200","description":"\u003ch1\u003e1751-018 NG gas valve conversion kit Robertshaw 7100 7200\u003c\/h1\u003e\n\u003cp\u003e\u003cmeta content=\"text\/html; charset=us-ascii\" http-equiv=\"Content-Type\"\u003e\u003c\/p\u003e\n\u003cstyle\u003e\na {\n    text-decoration: none;\n    color: #464feb;\n}\ntr th, tr td {\n    border: 1px solid #e6e6e6;\n}\ntr th {\n    background-color: #f5f5f5;\n}\n\u003c\/style\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe \u003cstrong\u003e1751-018 Natural Gas (NG) Conversion Kit\u003c\/strong\u003e is designed for converting compatible \u003cstrong\u003eRobertshaw 7100 and 7200 Series non-step opening gas valves\u003c\/strong\u003e to operate at \u003cstrong\u003e3.5\" W.C. Natural Gas pressure\u003c\/strong\u003e. This OEM-style conversion kit includes the required \u003cstrong\u003espring and regulator cap\u003c\/strong\u003e for proper valve adjustment and safe furnace operation. Ideal for HVAC service technicians performing gas type conversions or replacing missing conversion components on compatible Robertshaw gas valve assemblies.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eCross-Reference\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e1751-018\u003c\/li\u003e\n\u003cli\u003eRobertshaw 1751-018\u003c\/li\u003e\n\u003cli\u003e7100 NG Conversion Kit\u003c\/li\u003e\n\u003cli\u003e7200 NG Conversion Kit\u003c\/li\u003e\n\u003cli\u003eNatural Gas Conversion Kit\u003c\/li\u003e\n\u003cli\u003e3.5\" WC NG Conversion Kit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eDirect OEM\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eYes\u003c\/strong\u003e – Designed for compatible Robertshaw 7100 and 7200 Series gas valves.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eCompatible Brands\u003c\/h2\u003e\n\u003cp\u003eCompatible with equipment using:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRobertshaw 7100 Series Gas Valves\u003c\/li\u003e\n\u003cli\u003eRobertshaw 7200 Series Gas Valves\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eApplication\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFurnace gas valve conversion\u003c\/li\u003e\n\u003cli\u003eHVAC natural gas conversions\u003c\/li\u003e\n\u003cli\u003eGas valve servicing\u003c\/li\u003e\n\u003cli\u003eResidential heating equipment\u003c\/li\u003e\n\u003cli\u003eCommercial heating equipment\u003c\/li\u003e\n\u003cli\u003eReplacement regulator conversion components\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eRelated Components\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRobertshaw 7100 gas valves\u003c\/li\u003e\n\u003cli\u003eRobertshaw 7200 gas valves\u003c\/li\u003e\n\u003cli\u003eGas valve regulators\u003c\/li\u003e\n\u003cli\u003eLP conversion kits\u003c\/li\u003e\n\u003cli\u003eFurnace ignition controls\u003c\/li\u003e\n\u003cli\u003eFlame sensors\u003c\/li\u003e\n\u003cli\u003ePressure switches\u003c\/li\u003e\n\u003cli\u003eGas valve wiring harnesses\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnician Notes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned for \u003cstrong\u003enon-step opening\u003c\/strong\u003e Robertshaw 7100 and 7200 valves.\u003c\/li\u003e\n\u003cli\u003eConverts valve operation to \u003cstrong\u003e3.5\" W.C. Natural Gas\u003c\/strong\u003e settings.\u003c\/li\u003e\n\u003cli\u003eKit includes replacement spring and regulator cap.\u003c\/li\u003e\n\u003cli\u003eVerify appliance fuel type and valve model before installation.\u003c\/li\u003e\n\u003cli\u003eFor LP gas conversion applications, use \u003cstrong\u003e1751-016\u003c\/strong\u003e conversion kit.\u003c\/li\u003e\n\u003cli\u003eAll gas conversions should be performed by qualified HVAC service personnel.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eCommon Symptoms of Failure\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eIncorrect gas pressure settings\u003c\/li\u003e\n\u003cli\u003eImproper fuel conversion\u003c\/li\u003e\n\u003cli\u003ePoor burner performance\u003c\/li\u003e\n\u003cli\u003eDelayed ignition\u003c\/li\u003e\n\u003cli\u003eIncomplete combustion\u003c\/li\u003e\n\u003cli\u003eUnstable flame characteristics\u003c\/li\u003e\n\u003cli\u003eFurnace operational issues following gas valve servicing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eInstallation Tips\u003c\/h2\u003e\n\u003col\u003e\n\u003cli\u003eDisconnect electrical power and shut off gas supply.\u003c\/li\u003e\n\u003cli\u003eConfirm valve model compatibility before installation.\u003c\/li\u003e\n\u003cli\u003eFollow manufacturer conversion instructions precisely.\u003c\/li\u003e\n\u003cli\u003eInstall included spring and cap components.\u003c\/li\u003e\n\u003cli\u003eVerify manifold pressure after conversion.\u003c\/li\u003e\n\u003cli\u003eCheck for gas leaks upon completion.\u003c\/li\u003e\n\u003cli\u003eConfirm proper burner ignition and flame characteristics.\u003c\/li\u003e\n\u003cli\u003ePerform a complete system safety check before returning equipment to service.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003chr\u003e\n\u003ch2\u003eRecommended Inspection Items\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eGas valve model number\u003c\/li\u003e\n\u003cli\u003eManifold gas pressure\u003c\/li\u003e\n\u003cli\u003eBurner flame quality\u003c\/li\u003e\n\u003cli\u003eHeat exchanger condition\u003c\/li\u003e\n\u003cli\u003eGas supply pressure\u003c\/li\u003e\n\u003cli\u003eIgnition system operation\u003c\/li\u003e\n\u003cli\u003eVenting system condition\u003c\/li\u003e\n\u003cli\u003eCombustion air supply\u003c\/li\u003e\n\u003cli\u003eGas piping connections\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Neuco","offers":[{"title":"Default Title","offer_id":33235525326,"sku":"1751-018","price":31.24,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1071\/8320\/products\/1751-018.jpg?v=1739537859","url":"https:\/\/hvacpartstoremarket.com\/products\/1751-018-ng-gas-valve-conversion-kit-robertshaw-7100-7200","provider":"HVACpartstore","version":"1.0","type":"link"}