1751-018 NG gas valve conversion kit Robertshaw 7100 7200
1751-018 NG gas valve conversion kit Robertshaw 7100 7200
The 1751-018 Natural Gas (NG) Conversion Kit is designed for converting compatible Robertshaw 7100 and 7200 Series non-step opening gas valves to operate at 3.5" W.C. Natural Gas pressure. This OEM-style conversion kit includes the required spring and regulator cap for proper valve adjustment and safe furnace operation. Ideal for HVAC service technicians performing gas type conversions or replacing missing conversion components on compatible Robertshaw gas valve assemblies.
Cross-Reference
- 1751-018
- Robertshaw 1751-018
- 7100 NG Conversion Kit
- 7200 NG Conversion Kit
- Natural Gas Conversion Kit
- 3.5" WC NG Conversion Kit
Direct OEM
Yes – Designed for compatible Robertshaw 7100 and 7200 Series gas valves.
Compatible Brands
Compatible with equipment using:
- Robertshaw 7100 Series Gas Valves
- Robertshaw 7200 Series Gas Valves
Application
- Furnace gas valve conversion
- HVAC natural gas conversions
- Gas valve servicing
- Residential heating equipment
- Commercial heating equipment
- Replacement regulator conversion components
Related Components
- Robertshaw 7100 gas valves
- Robertshaw 7200 gas valves
- Gas valve regulators
- LP conversion kits
- Furnace ignition controls
- Flame sensors
- Pressure switches
- Gas valve wiring harnesses
Technician Notes
- Designed for non-step opening Robertshaw 7100 and 7200 valves.
- Converts valve operation to 3.5" W.C. Natural Gas settings.
- Kit includes replacement spring and regulator cap.
- Verify appliance fuel type and valve model before installation.
- For LP gas conversion applications, use 1751-016 conversion kit.
- All gas conversions should be performed by qualified HVAC service personnel.
Common Symptoms of Failure
- Incorrect gas pressure settings
- Improper fuel conversion
- Poor burner performance
- Delayed ignition
- Incomplete combustion
- Unstable flame characteristics
- Furnace operational issues following gas valve servicing
Installation Tips
- Disconnect electrical power and shut off gas supply.
- Confirm valve model compatibility before installation.
- Follow manufacturer conversion instructions precisely.
- Install included spring and cap components.
- Verify manifold pressure after conversion.
- Check for gas leaks upon completion.
- Confirm proper burner ignition and flame characteristics.
- Perform a complete system safety check before returning equipment to service.
Recommended Inspection Items
- Gas valve model number
- Manifold gas pressure
- Burner flame quality
- Heat exchanger condition
- Gas supply pressure
- Ignition system operation
- Venting system condition
- Combustion air supply
- Gas piping connections