{"product_id":"1751-016-lp-gas-valve-conversion-kit-robertshaw-7100-7200","title":"1751-016 LP gas valve conversion kit Robertshaw 7100 7200","description":"\u003ch1\u003e1751-016 LP gas valve conversion kit Robertshaw 7100 7200\u003c\/h1\u003e\n\u003cp\u003e\u003cmeta content=\"text\/html; charset=us-ascii\" http-equiv=\"Content-Type\"\u003e\u003c\/p\u003e\n\u003cstyle\u003e\na {\n    text-decoration: none;\n    color: #464feb;\n}\ntr th, tr td {\n    border: 1px solid #e6e6e6;\n}\ntr th {\n    background-color: #f5f5f5;\n}\n\u003c\/style\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe \u003cstrong\u003e1751-016 LP Conversion Kit\u003c\/strong\u003e is designed to convert compatible \u003cstrong\u003eRobertshaw 7100 and 7200 Series non-step opening gas valves\u003c\/strong\u003e for use with \u003cstrong\u003eLiquid Propane (LP) gas\u003c\/strong\u003e at \u003cstrong\u003e11.0\" W.C. manifold pressure\u003c\/strong\u003e. This conversion kit includes the required \u003cstrong\u003eregulator spring\u003c\/strong\u003e and the distinctive \u003cstrong\u003ered regulator cap\u003c\/strong\u003e for proper identification and adjustment. Ideal for furnace and heating equipment fuel conversions, the 1751-016 helps ensure safe and reliable LP gas operation when installed and adjusted by qualified HVAC technicians.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eCross-Reference\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e1751-016\u003c\/li\u003e\n\u003cli\u003eRobertshaw 1751-016\u003c\/li\u003e\n\u003cli\u003eLP Conversion Kit\u003c\/li\u003e\n\u003cli\u003ePropane Conversion Kit\u003c\/li\u003e\n\u003cli\u003e7100 LP Conversion Kit\u003c\/li\u003e\n\u003cli\u003e7200 LP Conversion Kit\u003c\/li\u003e\n\u003cli\u003e11.0\" WC LP Conversion Kit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eDirect OEM\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eYes\u003c\/strong\u003e – Designed for compatible Robertshaw 7100 and 7200 non-step opening gas valves.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eCompatible Brands\u003c\/h2\u003e\n\u003cp\u003eCompatible with equipment utilizing:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRobertshaw 7100 Series Gas Valves\u003c\/li\u003e\n\u003cli\u003eRobertshaw 7200 Series Gas Valves\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eApplication\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eLP gas furnace conversions\u003c\/li\u003e\n\u003cli\u003ePropane heating systems\u003c\/li\u003e\n\u003cli\u003eResidential HVAC equipment\u003c\/li\u003e\n\u003cli\u003eCommercial heating equipment\u003c\/li\u003e\n\u003cli\u003eGas valve fuel conversions\u003c\/li\u003e\n\u003cli\u003eReplacement regulator conversion components\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eRelated Components\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRobertshaw 7100 Gas Valve\u003c\/li\u003e\n\u003cli\u003eRobertshaw 7200 Gas Valve\u003c\/li\u003e\n\u003cli\u003eGas valve regulators\u003c\/li\u003e\n\u003cli\u003eNatural Gas conversion kits\u003c\/li\u003e\n\u003cli\u003eIgnition controls\u003c\/li\u003e\n\u003cli\u003eFlame sensors\u003c\/li\u003e\n\u003cli\u003ePressure switches\u003c\/li\u003e\n\u003cli\u003eFurnace control boards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnician Notes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned specifically for \u003cstrong\u003enon-step opening Robertshaw 7100 and 7200 gas valves\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eConfigures the regulator for \u003cstrong\u003e11.0\" W.C. LP gas operation\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eIncludes replacement spring and \u003cstrong\u003ered identification cap\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eVerify appliance fuel type and valve compatibility before installation.\u003c\/li\u003e\n\u003cli\u003eFor Natural Gas applications, use \u003cstrong\u003e1751-018\u003c\/strong\u003e conversion kit.\u003c\/li\u003e\n\u003cli\u003eGas conversions and pressure adjustments should be performed by qualified personnel and verified with a calibrated manometer.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eCommon Symptoms of Failure\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eIncorrect manifold gas pressure\u003c\/li\u003e\n\u003cli\u003eImproper propane conversion\u003c\/li\u003e\n\u003cli\u003eDelayed ignition\u003c\/li\u003e\n\u003cli\u003eWeak or unstable burner flame\u003c\/li\u003e\n\u003cli\u003eIncomplete combustion\u003c\/li\u003e\n\u003cli\u003eFurnace lockouts\u003c\/li\u003e\n\u003cli\u003ePoor heating performance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eInstallation Tips\u003c\/h2\u003e\n\u003col\u003e\n\u003cli\u003eShut off power and gas supply before servicing.\u003c\/li\u003e\n\u003cli\u003eVerify valve model compatibility.\u003c\/li\u003e\n\u003cli\u003eFollow the appliance manufacturer's conversion procedures.\u003c\/li\u003e\n\u003cli\u003eInstall the included spring and red regulator cap.\u003c\/li\u003e\n\u003cli\u003eAdjust and verify manifold pressure at 11.0\" W.C.\u003c\/li\u003e\n\u003cli\u003eCheck all gas connections for leaks.\u003c\/li\u003e\n\u003cli\u003eConfirm proper ignition and flame characteristics.\u003c\/li\u003e\n\u003cli\u003eComplete a full operational safety test before placing equipment back into service.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003chr\u003e\n\u003ch2\u003eRecommended Inspection Items\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eGas valve model number\u003c\/li\u003e\n\u003cli\u003eManifold pressure\u003c\/li\u003e\n\u003cli\u003eBurner assembly condition\u003c\/li\u003e\n\u003cli\u003eIgnition system operation\u003c\/li\u003e\n\u003cli\u003eHeat exchanger condition\u003c\/li\u003e\n\u003cli\u003eVenting system\u003c\/li\u003e\n\u003cli\u003ePropane supply pressure\u003c\/li\u003e\n\u003cli\u003eGas piping connections\u003c\/li\u003e\n\u003cli\u003eFlame appearance and stability\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Neuco","offers":[{"title":"Default Title","offer_id":33233060686,"sku":"1751-016","price":32.24,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1071\/8320\/products\/1751-016.jpg?v=1739537860","url":"https:\/\/hvacpartstoremarket.com\/products\/1751-016-lp-gas-valve-conversion-kit-robertshaw-7100-7200","provider":"HVACpartstore","version":"1.0","type":"link"}