1751-016 LP gas valve conversion kit Robertshaw 7100 7200
1751-016 LP gas valve conversion kit Robertshaw 7100 7200
The 1751-016 LP Conversion Kit is designed to convert compatible Robertshaw 7100 and 7200 Series non-step opening gas valves for use with Liquid Propane (LP) gas at 11.0" W.C. manifold pressure. This conversion kit includes the required regulator spring and the distinctive red regulator cap for proper identification and adjustment. Ideal for furnace and heating equipment fuel conversions, the 1751-016 helps ensure safe and reliable LP gas operation when installed and adjusted by qualified HVAC technicians.
Cross-Reference
- 1751-016
- Robertshaw 1751-016
- LP Conversion Kit
- Propane Conversion Kit
- 7100 LP Conversion Kit
- 7200 LP Conversion Kit
- 11.0" WC LP Conversion Kit
Direct OEM
Yes – Designed for compatible Robertshaw 7100 and 7200 non-step opening gas valves.
Compatible Brands
Compatible with equipment utilizing:
- Robertshaw 7100 Series Gas Valves
- Robertshaw 7200 Series Gas Valves
Application
- LP gas furnace conversions
- Propane heating systems
- Residential HVAC equipment
- Commercial heating equipment
- Gas valve fuel conversions
- Replacement regulator conversion components
Related Components
- Robertshaw 7100 Gas Valve
- Robertshaw 7200 Gas Valve
- Gas valve regulators
- Natural Gas conversion kits
- Ignition controls
- Flame sensors
- Pressure switches
- Furnace control boards
Technician Notes
- Designed specifically for non-step opening Robertshaw 7100 and 7200 gas valves.
- Configures the regulator for 11.0" W.C. LP gas operation.
- Includes replacement spring and red identification cap.
- Verify appliance fuel type and valve compatibility before installation.
- For Natural Gas applications, use 1751-018 conversion kit.
- Gas conversions and pressure adjustments should be performed by qualified personnel and verified with a calibrated manometer.
Common Symptoms of Failure
- Incorrect manifold gas pressure
- Improper propane conversion
- Delayed ignition
- Weak or unstable burner flame
- Incomplete combustion
- Furnace lockouts
- Poor heating performance
Installation Tips
- Shut off power and gas supply before servicing.
- Verify valve model compatibility.
- Follow the appliance manufacturer's conversion procedures.
- Install the included spring and red regulator cap.
- Adjust and verify manifold pressure at 11.0" W.C.
- Check all gas connections for leaks.
- Confirm proper ignition and flame characteristics.
- Complete a full operational safety test before placing equipment back into service.
Recommended Inspection Items
- Gas valve model number
- Manifold pressure
- Burner assembly condition
- Ignition system operation
- Heat exchanger condition
- Venting system
- Propane supply pressure
- Gas piping connections
- Flame appearance and stability