14SH22-309105 York Therm-O-Disc, 24V, SPDT (SPNO/SPNC), 3 Switches, 2 Timing, Heat Sequencer Relay (On: 1-110s, Off: 1-110s)

The 14SH22-309105 Heat Sequencer Relay is a Therm-O-Disc manufactured HVAC control designed to sequence electric heating elements and blower operations in electric furnaces and air handlers. Operating on 24 VAC control voltage, this sequencer features three switch circuits with two timing functions, utilizing SPDT (Single Pole Double Throw) contacts with both normally open and normally closed outputs. With 1-110 second ON timing and 1-110 second OFF timing, the relay provides controlled staging of heating circuits, helping reduce electrical load spikes while ensuring proper heater and blower sequencing.


Cross-Reference

  • 14SH22-309105
  • Therm-O-Disc 14SH22-309105
  • 14SH22309105
  • Heat Sequencer Relay
  • Electric Furnace Sequencer
  • 24V Sequencer Relay

Direct OEM

Yes – OEM-style Therm-O-Disc heat sequencer relay.


Compatible Brands

  • York
  • Coleman
  • Luxaire
  • Fraser-Johnston
  • Air Pro
  • Evcon

Compatible with many electric furnaces and air handlers utilizing a Therm-O-Disc 24V sequencer.


Application

  • Electric furnaces
  • Electric air handlers
  • Heat strip sequencing
  • Blower motor control
  • Electric resistance heating systems
  • HVAC staging controls

Related Components

  • Electric heat strips
  • Limit switches
  • Fan relays
  • Contactors
  • Blower motors
  • Transformer assemblies
  • Control boards
  • Thermostats

Technician Notes

  • 24 VAC control voltage.
  • Three switching circuits.
  • SPDT contact configuration.
  • Normally Open (NO) and Normally Closed (NC) outputs.
  • Timed operation helps prevent excessive inrush current.
  • Designed for sequential activation and deactivation of heating elements.
  • Verify timing and terminal configuration before replacement.

Common Symptoms of Failure

  • No heat from electric furnace
  • Partial heat operation
  • Heating elements not staging properly
  • Blower fails to operate correctly
  • Heat strips remain energized
  • Intermittent heating operation
  • Burned or welded contacts
  • Furnace trips high-limit controls

Installation Tips

  1. Disconnect power before servicing.
  2. Record terminal locations before removing the old sequencer.
  3. Verify terminal count and switch configuration.
  4. Transfer wires one terminal at a time.
  5. Secure relay firmly to mounting surface.
  6. Inspect wiring for signs of overheating.
  7. Test heating stages after installation.
  8. Confirm proper blower sequencing during operation.

Recommended Inspection Items

  • Heat strip condition
  • Electrical connections
  • Contactor contacts
  • Blower motor operation
  • Transformer output voltage
  • High-limit switches
  • Control board outputs
  • Wiring insulation condition
  • Supply voltage and amperage