colemanhvacparts.com, www.darindevries.com

1497-0861 Coleman 88-108 MFD 165V Round Start Capacitor

  • $ 19.80
    Unit price per 
  • Save $ 1.39
Shipping calculated at checkout.


1497-0861 Coleman 88-108 MFD 165V Round Start Capacitor

In Stock

Plastic housing measures 1-7/16" diameter x 2-3/4" height.

The Coleman 1497-0861 Round Start Capacitor is an OEM 88-108 MFD, 165VAC start capacitor designed to provide the extra starting torque required for HVAC compressors and electric motors. This round capacitor helps reduce startup strain, improves compressor performance, and supports reliable operation in compatible Coleman, York, Evcon, and other HVAC systems. Its compact plastic housing measures approximately 1-7/16" diameter by 2-3/4" height.


Cross-Reference

  • Coleman 1497-0861
  • C1497-0861
  • 1497-086
  • 1497-087
  • 235-0843-03
  • Mars 11076

Direct OEM

Coleman 1497-0861


Compatible Brands

  • Coleman
  • York
  • Evcon
  • Luxaire
  • Johnson Controls

Application

Used in HVAC equipment to:

  • Assist compressor startup
  • Increase motor starting torque
  • Reduce locked-rotor startup conditions
  • Improve compressor efficiency
  • Support hard-start applications

Often paired with:

  • WSX-5ACM Start Device
  • WSX-7 Start Device
  • Part Number 310977.005

Related Components

  • Start Relay
  • Potential Relay
  • Hard Start Kit
  • Run Capacitor
  • Compressor Contactor
  • Compressor
  • Condenser Fan Motor
  • Start Device WSX-5ACM
  • Start Device WSX-7 (310977.005)

Technician Notes

The 1497-0861 is a round start capacitor rated at 88-108 MFD and 165 VAC. Start capacitors are intermittent-duty components and should be used only in circuits designed for capacitor-assisted starting. When replacing, always verify microfarad rating, voltage rating, and compatibility with the start relay or hard start device being used.

A weak or failed start capacitor can cause excessive compressor amperage, delayed startup, overheating, or nuisance breaker trips.


Common Symptoms of Failure

  • Compressor will not start
  • Compressor hums but does not run
  • Hard starting air conditioner
  • Tripped breaker during startup
  • Blown fuse
  • Intermittent cooling
  • Overheated compressor
  • Excessive startup current draw
  • System short cycles

Installation Tips

  1. Disconnect power before servicing.
  2. Discharge the old capacitor before removal.
  3. Verify the replacement matches the original MFD rating.
  4. Inspect the start relay or potential relay during replacement.
  5. Check terminals for corrosion or loose connections.
  6. Secure capacitor in the mounting bracket.
  7. Test compressor startup after installation.
  8. Verify operating amperage remains within specifications.

Recommended Inspection Items

  • Start relay
  • Potential relay
  • WSX-5ACM start device
  • WSX-7 start device
  • Run capacitor
  • Compressor winding resistance
  • Contactor condition
  • Electrical terminals
  • Supply voltage
  • Compressor amperage

We Also Recommend