{"product_id":"1472-1161-coleman-mach-blower-wheel-outdoor-condenser-side","title":"1472-1161 Coleman MACH Blower Wheel Outdoor Condenser Side","description":"\u003ch1\u003e1472-1161 Coleman MACH Blower Wheel Outdoor Condenser Side\u003c\/h1\u003e\n\u003cstyle\u003e\na {\n    text-decoration: none;\n    color: #464feb;\n}\ntr th, tr td {\n    border: 1px solid #e6e6e6;\n}\ntr th {\n    background-color: #f5f5f5;\n}\n\u003c\/style\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe \u003cstrong\u003eColeman‑Mach 1472‑1161 Condenser Blower Wheel\u003c\/strong\u003e is a genuine OEM replacement fan wheel designed for the \u003cstrong\u003eoutdoor condenser side\u003c\/strong\u003e of Coleman‑Mach rooftop air conditioners. This blower wheel moves outside air across the condenser coil, allowing heat to be removed from the refrigerant and maintaining proper cooling performance.\u003c\/p\u003e\n\u003cp\u003eManufactured to Airxcel Coleman‑Mach specifications, the \u003cstrong\u003e1472‑1161\u003c\/strong\u003e restores proper condenser airflow when the original blower wheel becomes cracked, warped, loose on the motor shaft, or damaged from extended operation. Proper condenser airflow is critical for compressor efficiency, cooling capacity, operating pressures, and rooftop A\/C longevity.\u003c\/p\u003e\n\u003cp\u003eThis OEM replacement helps maintain factory cooling performance while reducing vibration, noise, and airflow restrictions.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003e Cross‑Reference \u003c\/h2\u003e\n\u003ch3\u003e\u003cstrong\u003eDirect OEM\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e1472‑1161\u003c\/strong\u003e — Coleman‑Mach Outdoor Condenser Blower Wheel\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eColeman‑Mach\u003c\/li\u003e\n\u003cli\u003eAirxcel\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRooftop RV Air Conditioners\u003c\/li\u003e\n\u003cli\u003eCondenser Fan Assemblies\u003c\/li\u003e\n\u003cli\u003eOutdoor Airflow Systems\u003c\/li\u003e\n\u003cli\u003eColeman‑Mach Cooling Units\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePulls outdoor air across condenser coil\u003c\/li\u003e\n\u003cli\u003eRemoves heat from refrigerant\u003c\/li\u003e\n\u003cli\u003eSupports compressor efficiency\u003c\/li\u003e\n\u003cli\u003eMaintains rooftop A\/C cooling performance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eRelated Components\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e8333A9021 Hard Start Kit\u003c\/li\u003e\n\u003cli\u003eCondenser Fan Motors\u003c\/li\u003e\n\u003cli\u003eEvaporator Blower Wheels\u003c\/li\u003e\n\u003cli\u003eRun Capacitors\u003c\/li\u003e\n\u003cli\u003eRooftop A\/C Shrouds\u003c\/li\u003e\n\u003cli\u003eControl Boards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003e Technician Notes\u003c\/h2\u003e\n\u003ch3\u003eCommon Symptoms of Failure\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eExcessive rooftop A\/C vibration\u003c\/li\u003e\n\u003cli\u003eReduced cooling performance\u003c\/li\u003e\n\u003cli\u003eCondenser fan noise\u003c\/li\u003e\n\u003cli\u003eBroken or cracked blower wheel\u003c\/li\u003e\n\u003cli\u003eHigh compressor head pressure\u003c\/li\u003e\n\u003cli\u003eWheel slipping on motor shaft\u003c\/li\u003e\n\u003cli\u003eReduced outdoor airflow\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Tips\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInspect condenser motor shaft for wear before installation.\u003c\/li\u003e\n\u003cli\u003eClean condenser coil while the unit is disassembled.\u003c\/li\u003e\n\u003cli\u003eVerify wheel is centered in the housing.\u003c\/li\u003e\n\u003cli\u003eTighten hub fasteners securely.\u003c\/li\u003e\n\u003cli\u003eCheck for blade or housing contact before restoring power.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eRecommended Inspection Items\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCondenser fan motor\u003c\/li\u003e\n\u003cli\u003eRun capacitor\u003c\/li\u003e\n\u003cli\u003eCondenser coil\u003c\/li\u003e\n\u003cli\u003eRooftop shroud\u003c\/li\u003e\n\u003cli\u003eCompressor compartment\u003c\/li\u003e\n\u003cli\u003eMounting hardware\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch2\u003e\u003cspan style=\"background-color: rgb(255, 255, 0);\"\u003e\u003cstrong\u003eImportant:\u003c\/strong\u003e This wheel is \u003cstrong\u003enot\u003c\/strong\u003e used on Mach 8 units \u003c\/span\u003e\u003c\/h2\u003e\n\u003ch2\u003e\u003cspan style=\"background-color: rgb(255, 255, 0);\"\u003ethose use \u003ca href=\"https:\/\/hvacpartstoremarket.com\/products\/1472a1191-coleman-air-conditioner-1472a1191-blower-wheel?_pos=952\u0026amp;_sid=7cc9bd35f\u0026amp;_ss=r\"\u003e\u003cstrong\u003e1472A1191\u003c\/strong\u003e \u003c\/a\u003einstead.\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Laurelhurst","offers":[{"title":"Default Title","offer_id":45250647949378,"sku":"C1472-1161","price":130.58,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1071\/8320\/files\/Screenshot2026-09-20120241.png?v=1789930973","url":"https:\/\/hvacpartstoremarket.com\/products\/1472-1161-coleman-mach-blower-wheel-outdoor-condenser-side","provider":"HVACpartstore","version":"1.0","type":"link"}