{"product_id":"122770-aerco-boiler-aerco-vacuum-breaker","title":"122770 AERCO Boiler AERCO VACUUM BREAKER","description":"\u003ch1\u003e122770 AERCO Boiler AERCO VACUUM BREAKER\u003c\/h1\u003e\n\u003cp\u003e\u003cspan style=\"font-size: large;\"\u003e\u003cspan style=\"background-color: rgb(255, 255, 0);\"\u003e\u003cb\u003eNormal Stock Item\u003c\/b\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cmeta content=\"text\/html; charset=us-ascii\" http-equiv=\"Content-Type\"\u003e\u003c\/p\u003e\n\u003cstyle\u003e\na {\n    text-decoration: none;\n    color: #464feb;\n}\ntr th, tr td {\n    border: 1px solid #e6e6e6;\n}\ntr th {\n    background-color: #f5f5f5;\n}\n\u003c\/style\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe \u003cstrong\u003e122770 AERCO Vacuum Breaker\u003c\/strong\u003e is a genuine OEM replacement component designed for use in compatible AERCO commercial boilers and water heaters. This critical plumbing and system protection device helps prevent vacuum conditions from developing within the water system by allowing air to enter when negative pressure occurs. Proper vacuum breaker operation helps protect system components, maintain safe operating conditions, and support reliable water circulation within commercial heating and domestic hot water applications.\u003c\/p\u003e\n\u003cp\u003eManufactured to AERCO factory specifications, the 122770 Vacuum Breaker provides dependable performance and is an important component in maintaining overall system integrity and equipment protection.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eCross-Reference\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e122770\u003c\/li\u003e\n\u003cli\u003eAERCO 122770\u003c\/li\u003e\n\u003cli\u003eVacuum Breaker\u003c\/li\u003e\n\u003cli\u003eBoiler Vacuum Breaker\u003c\/li\u003e\n\u003cli\u003eWater Heater Vacuum Breaker\u003c\/li\u003e\n\u003cli\u003eSystem Vacuum Relief Device\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eDirect OEM\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eYes\u003c\/strong\u003e – Genuine AERCO OEM replacement vacuum breaker.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eCompatible Brands\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eAERCO\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCompatible with select:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAERCO Commercial Boilers\u003c\/li\u003e\n\u003cli\u003eAERCO Commercial Water Heaters\u003c\/li\u003e\n\u003cli\u003eAERCO Benchmark Boilers\u003c\/li\u003e\n\u003cli\u003eAERCO Hydronic Heating Systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAlways verify compatibility using the equipment model and serial number prior to ordering.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eApplication\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eCommercial boiler systems\u003c\/li\u003e\n\u003cli\u003eCommercial water heaters\u003c\/li\u003e\n\u003cli\u003eHydronic heating systems\u003c\/li\u003e\n\u003cli\u003eWater circulation systems\u003c\/li\u003e\n\u003cli\u003eVacuum prevention applications\u003c\/li\u003e\n\u003cli\u003eBoiler and water heater safety systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eRelated Components\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFlow Sensors\u003c\/li\u003e\n\u003cli\u003eWater Outlet Temperature Sensors\u003c\/li\u003e\n\u003cli\u003eDigital Limit Controls\u003c\/li\u003e\n\u003cli\u003eAir Inlet Temperature Sensors\u003c\/li\u003e\n\u003cli\u003ePressure Relief Valves\u003c\/li\u003e\n\u003cli\u003eExpansion Tanks\u003c\/li\u003e\n\u003cli\u003eCirculation Pumps\u003c\/li\u003e\n\u003cli\u003eAnnual Maintenance Kits\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnician Notes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eGenuine OEM AERCO replacement component.\u003c\/li\u003e\n\u003cli\u003eDesigned to prevent damaging vacuum conditions within the system.\u003c\/li\u003e\n\u003cli\u003eHelps protect piping, heat exchangers, and associated water-side components.\u003c\/li\u003e\n\u003cli\u003eInspect during routine maintenance intervals.\u003c\/li\u003e\n\u003cli\u003eVerify proper installation orientation.\u003c\/li\u003e\n\u003cli\u003eCheck surrounding piping and fittings for leaks or signs of corrosion.\u003c\/li\u003e\n\u003cli\u003eReplace if sticking, leaking, or damaged.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eCommon Symptoms of Failure\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eWater leakage around the vacuum breaker\u003c\/li\u003e\n\u003cli\u003eVacuum-related system issues\u003c\/li\u003e\n\u003cli\u003eAir infiltration concerns\u003c\/li\u003e\n\u003cli\u003eImproper pressure equalization\u003c\/li\u003e\n\u003cli\u003eCorroded or damaged body\u003c\/li\u003e\n\u003cli\u003eIntermittent system performance problems\u003c\/li\u003e\n\u003cli\u003eComponent sticking or blockage\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eInstallation Tips\u003c\/h2\u003e\n\u003col\u003e\n\u003cli\u003eShut down and isolate the equipment before servicing.\u003c\/li\u003e\n\u003cli\u003eRelieve system pressure following manufacturer procedures.\u003c\/li\u003e\n\u003cli\u003eVerify replacement part number compatibility.\u003c\/li\u003e\n\u003cli\u003eInspect threaded connections and piping condition.\u003c\/li\u003e\n\u003cli\u003eInstall according to AERCO specifications.\u003c\/li\u003e\n\u003cli\u003eRestore system pressure and inspect for leaks.\u003c\/li\u003e\n\u003cli\u003eVerify proper system operation after installation.\u003c\/li\u003e\n\u003cli\u003eInspect associated safety devices during service.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003chr\u003e\n\u003ch2\u003eRecommended Inspection Items\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSystem pressure relief valves\u003c\/li\u003e\n\u003cli\u003eExpansion tanks\u003c\/li\u003e\n\u003cli\u003eFlow sensors\u003c\/li\u003e\n\u003cli\u003eWater circulation pumps\u003c\/li\u003e\n\u003cli\u003ePiping connections\u003c\/li\u003e\n\u003cli\u003eWater outlet temperature sensors\u003c\/li\u003e\n\u003cli\u003eBoiler safety controls\u003c\/li\u003e\n\u003cli\u003eHeat exchanger condition\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Neuco","offers":[{"title":"Default Title","offer_id":42447096283202,"sku":"122770","price":1268.7,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1071\/8320\/files\/Screenshot2025-12-18195354.png?v=1766112872","url":"https:\/\/hvacpartstoremarket.com\/products\/122770-aerco-boiler-aerco-vacuum-breaker","provider":"HVACpartstore","version":"1.0","type":"link"}