colemanhvacparts.com, www.darindevries.com

1045338R Nordyne REPL,LIM,3/4D,1S,OR,225,F,A,F

  • $ 26.73
    Unit price per 
  • Save $ 3.26
Shipping calculated at checkout.


1045338R Nordyne REPL,LIM,3/4D,1S,OR,225,F,A,F

In Stock

The 1045338R Nordyne Limit Switch is a genuine OEM furnace safety control designed to protect heating equipment from overheating conditions. This 3/4-inch disc limit switch features a 225°F Open-on-Rise (OR) temperature rating and serves as a critical safety device that interrupts the circuit when excessive temperatures are detected within the furnace cabinet or heat exchanger area. Commonly used in Nordyne-manufactured equipment, including Intertherm and Miller furnaces, this switch helps prevent damage to vital furnace components while maintaining safe system operation.


Cross-Reference

  • 1045338R
  • Nordyne 1045338R
  • 225°F Limit Switch
  • 3/4" Disc Limit Switch
  • Open on Rise Limit Switch
  • OR 225°F Limit

Direct OEM

Yes – Genuine Nordyne OEM replacement part.


Compatible Brands

  • Nordyne
  • Intertherm
  • Miller
  • Broan
  • Frigidaire
  • Maytag
  • Gibson
  • Tappan
  • Kelvinator
  • Philco

Application

  • Gas furnaces
  • Mobile home furnaces
  • Manufactured housing furnaces
  • Heat exchanger protection circuits
  • High-temperature safety controls
  • Primary furnace limit applications

Related Components

  • Rollout switches
  • Fan limit controls
  • Pressure switches
  • Flame sensors
  • Ignitors
  • Control boards
  • Blower motors
  • Temperature safety switches

Technician Notes

  • Temperature rating: 225°F Open on Rise (OR).
  • 3/4-inch disc style limit switch.
  • First-stage furnace safety limit.
  • Opens the circuit when temperatures exceed the rated limit.
  • Repeated limit switch failures often indicate airflow restrictions or overheating issues.
  • Always investigate the cause of overheating before replacing the switch.

Common Symptoms of Failure

  • Furnace will not operate
  • No heat condition
  • Open limit switch fault codes
  • Burner shuts down prematurely
  • Intermittent heating cycles
  • Furnace lockout condition
  • Overheating safety shutdowns

Installation Tips

  1. Disconnect electrical power before servicing.
  2. Verify replacement temperature rating matches the original switch.
  3. Inspect wiring terminals for heat damage.
  4. Mount the limit switch securely in the original location.
  5. Ensure proper terminal connections.
  6. Restore power and verify safe furnace operation.
  7. Confirm proper airflow through the furnace system.

Recommended Inspection Items

  • Air filter condition
  • Blower wheel cleanliness
  • Blower motor operation
  • Evaporator coil restrictions
  • Supply and return airflow
  • Venting system condition
  • Heat exchanger area
  • Wiring terminals and connectors
  • Furnace temperature rise

We Also Recommend