1045337R Nordyne Replacement Limit 3/4D 2S OR 225 F A F
1045337R Nordyne Replacement Limit 3/4D 2S OR 225F
Normal Stock Item
The Nordyne 1045337R Replacement Limit Switch is a 225°F automatic reset furnace limit control designed to protect compatible Nordyne, Intertherm, and Miller heating systems from overheating. Featuring a compact 3/4-inch disc design with 2 terminals, this safety switch automatically opens when temperature reaches its rated limit and resets after cooling, helping safeguard the heat exchanger and furnace components from excessive heat.
Cross-Reference
- Nordyne 1045337R
- 1045337
- 1045337R Limit Switch
- 225°F Furnace Limit
- 3/4D 2S OR 225F
Direct OEM
Nordyne 1045337R
Compatible Brands
- Nordyne
- Intertherm
- Miller
- Frigidaire
- Broan
- Maytag
- Tappan
- Westinghouse
Application
Used in compatible furnaces and heating systems to:
- Protect against overheating
- Interrupt burner operation at unsafe temperatures
- Protect heat exchangers and cabinet components
- Restore operation automatically after cooling
- Maintain safe furnace operation
Related Components
- High Limit Switch
- Fan Limit Control
- Rollout Switch
- Furnace Control Board
- Blower Motor
- Transformer
- Gas Valve
- Flame Sensor
Technician Notes
The 1045337R is an automatic-reset temperature limit switch rated to open at 225°F. When this limit opens repeatedly, the root cause is often restricted airflow, a failing blower motor, dirty evaporator coil, plugged filter, or improper gas input. Always diagnose the underlying overheating condition before replacing the limit switch.
Common Symptoms of Failure
- Furnace will not heat
- Intermittent heating operation
- Furnace shuts down on limit
- Short cycling
- Open limit fault codes
- Burner ignition without sustained operation
- Repeated safety lockouts
- No continuity through limit switch
Installation Tips
- Disconnect electrical power before servicing.
- Verify temperature rating matches the original part.
- Inspect mounting location for signs of overheating.
- Transfer wiring carefully to avoid terminal damage.
- Check for restricted airflow conditions.
- Verify blower operation and temperature rise.
- Test continuity before and after installation.
- Confirm proper system operation after startup.
Recommended Inspection Items
- Air filter condition
- Blower motor amperage
- Evaporator coil cleanliness
- Supply and return airflow
- Heat exchanger condition
- Burner flame pattern
- Control board diagnostics
- Venting system condition
- Gas pressure settings