1045337R Nordyne Replacement Limit 3/4D 2S OR 225 F A F

  • $ 32.09
    Unit price per 
  • Save $ 7.90
Shipping calculated at checkout.


1045337R Nordyne Replacement Limit 3/4D 2S OR 225F

Normal Stock Item

The Nordyne 1045337R Replacement Limit Switch is a 225°F automatic reset furnace limit control designed to protect compatible Nordyne, Intertherm, and Miller heating systems from overheating. Featuring a compact 3/4-inch disc design with 2 terminals, this safety switch automatically opens when temperature reaches its rated limit and resets after cooling, helping safeguard the heat exchanger and furnace components from excessive heat.


Cross-Reference

  • Nordyne 1045337R
  • 1045337
  • 1045337R Limit Switch
  • 225°F Furnace Limit
  • 3/4D 2S OR 225F

Direct OEM

Nordyne 1045337R


Compatible Brands

  • Nordyne
  • Intertherm
  • Miller
  • Frigidaire
  • Broan
  • Maytag
  • Tappan
  • Westinghouse

Application

Used in compatible furnaces and heating systems to:

  • Protect against overheating
  • Interrupt burner operation at unsafe temperatures
  • Protect heat exchangers and cabinet components
  • Restore operation automatically after cooling
  • Maintain safe furnace operation

Related Components

  • High Limit Switch
  • Fan Limit Control
  • Rollout Switch
  • Furnace Control Board
  • Blower Motor
  • Transformer
  • Gas Valve
  • Flame Sensor

Technician Notes

The 1045337R is an automatic-reset temperature limit switch rated to open at 225°F. When this limit opens repeatedly, the root cause is often restricted airflow, a failing blower motor, dirty evaporator coil, plugged filter, or improper gas input. Always diagnose the underlying overheating condition before replacing the limit switch.


Common Symptoms of Failure

  • Furnace will not heat
  • Intermittent heating operation
  • Furnace shuts down on limit
  • Short cycling
  • Open limit fault codes
  • Burner ignition without sustained operation
  • Repeated safety lockouts
  • No continuity through limit switch

Installation Tips

  1. Disconnect electrical power before servicing.
  2. Verify temperature rating matches the original part.
  3. Inspect mounting location for signs of overheating.
  4. Transfer wiring carefully to avoid terminal damage.
  5. Check for restricted airflow conditions.
  6. Verify blower operation and temperature rise.
  7. Test continuity before and after installation.
  8. Confirm proper system operation after startup.

Recommended Inspection Items

  • Air filter condition
  • Blower motor amperage
  • Evaporator coil cleanliness
  • Supply and return airflow
  • Heat exchanger condition
  • Burner flame pattern
  • Control board diagnostics
  • Venting system condition
  • Gas pressure settings

We Also Recommend