L160-45F Limit Switch

The 0200-194-001P Amana L160-45F Limit Switch is a direct OEM replacement temperature safety control designed to protect furnace heat exchangers from overheating. Rated at L160-45F, this automatic reset limit switch opens at 160°F and resets when temperatures return to safe operating levels. Commonly used in Amana, Goodman, and Janitrol gas furnaces, this switch helps maintain safe furnace operation by interrupting the heating circuit during excessive temperature conditions.


Cross-Reference

  • 0200-194-001P
  • 0200194001P
  • L160-45F
  • B1370158
  • B13701-58
  • 10123533
  • PCBBF112
  • 42756

Direct OEM

Yes – Genuine OEM Amana / Goodman replacement limit switch.


Compatible Brands

  • Amana
  • Goodman
  • Janitrol
  • GMC
  • Daikin (select legacy Goodman systems)

Application

  • Gas Furnaces
  • Residential Forced-Air Heating Systems
  • Primary High Limit Temperature Protection
  • Heat Exchanger Over-Temperature Safety Circuit

Related Components

  • Flame Sensors
  • Pressure Switches
  • Rollout Switches
  • Furnace Control Boards
  • Inducer Motors
  • Blower Motors
  • Igniters
  • Air Filters

Technician Notes

  • L160-45F indicates the switch opens at 160°F and automatically resets after a 45°F temperature drop.
  • Always determine the root cause of the overheating condition before replacing the limit switch.
  • Frequent limit switch trips often indicate airflow restrictions or blower performance issues.
  • Verify proper temperature rise after installation.

Common Symptoms of Failure

  • Furnace shuts down before reaching set temperature.
  • Burners cycle on and off repeatedly.
  • Furnace runs briefly then locks out.
  • No heat condition with open limit circuit.
  • Diagnostic code indicating high limit switch fault.
  • Excessive cycling during heating demand.

Installation Tips

  1. Disconnect power to the furnace.
  2. Verify replacement switch matches the original temperature rating.
  3. Transfer wiring one terminal at a time.
  4. Secure the switch firmly to the mounting surface.
  5. Restore power and test furnace operation.
  6. Confirm proper temperature rise and airflow.

Recommended Inspection Items

  • Dirty or plugged air filter
  • Restricted return air ductwork
  • Closed or blocked supply registers
  • Blower wheel contamination
  • Weak or failing blower motor
  • Incorrect blower speed settings
  • Heat exchanger condition
  • Venting restrictions
  • Evaporator coil blockage
  • Furnace temperature rise measurements