{"title":"Dinosaur Electronics RV Aftermarket Controls","description":"\u003ch1\u003eDinosaur Electronics RV Aftermarket Controls\u003c\/h1\u003e\n\u003cdiv style=\"text-align: start;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1071\/8320\/files\/Screenshot_2026-11-23_115116_1024x1024.png?v=1795459997\" alt=\"\" style=\"float: none;\"\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cimg\u003e\u003cimg\u003e\u003c\/p\u003e\n\u003cdiv style=\"text-align: start;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1071\/8320\/files\/Screenshot_2026-11-23_115517_1024x1024.png?v=1795460168\" alt=\"\" style=\"float: none;\"\u003e\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e","products":[{"product_id":"uib-64-dinosaur-electronics-ignitor-board","title":"UIB 64 Dinosaur Electronics Ignitor Board (Atwood Water Heater)","description":"\u003ch1\u003eUIB 64 Dinosaur Electronics Ignitor Board \u003c\/h1\u003e\n\u003cp\u003e\u003cspan\u003eUNIVERSAL IGNITOR BOARD, FOR USE IN ATWOOD AC\/GAS WATER HEATERS WITH 6+4 PIN\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003cstrong\u003eDinosaur Electronics UIB 64 Ignitor Board\u003c\/strong\u003e is a universal, high‑reliability replacement control board designed for \u003cstrong\u003eAtwood AC\/Gas water heaters\u003c\/strong\u003e that use the \u003cstrong\u003e6‑pin + 4‑pin connector setup\u003c\/strong\u003e. Built with rugged components and fully protected circuitry, this board delivers dependable ignition performance and long service life in demanding RV environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis TEI‑certified board operates on \u003cstrong\u003e12 VDC\u003c\/strong\u003e, includes \u003cstrong\u003ethree diagnostic LEDs\u003c\/strong\u003e for fast troubleshooting, and features built‑in \u003cstrong\u003efuse and surge protection\u003c\/strong\u003e. The UIB 64 is jumper‑configurable for multiple applications and comes complete with a protective cover and mounting hardware for easy installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eUniversal replacement for Atwood AC\/Gas water heaters with \u003cstrong\u003e6+4 pin connectors\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e12 VDC operation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e3 diagnostic LEDs\u003c\/strong\u003e for quick fault identification\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eFuse \u0026amp; surge protected\u003c\/strong\u003e circuitry\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eJumper‑configurable\u003c\/strong\u003e for multiple applications\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIncludes \u003cstrong\u003ecover and mounting hardware\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eTEI Certified\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMade in the USA\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e3‑Year Manufacturer Warranty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eAlternate \/ OEM Part Numbers\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e02‑3957\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e023957\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e0310.1554\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e100510\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e23957\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eUIB64\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eIdeal for replacing failed or unreliable ignition boards in Atwood water heaters, improving reliability and ignition consistency in RV hot water systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe UIB 64 is a universal ignitor board specialized to work in Atwood’s® AC\/Gas water heaters with 4 + 6 header pin or edge style connectors, or with the single 10 pin connector used in Atwood's®  latest models. By resetting the jumpers it can function like a UIB S ignitor board so it can be configured to replace standard DSI ignitor boards that use a single 6 position connector found in older water heaters, refrigerators and furnaces.\u003c\/span\u003e\u003c\/p\u003e","brand":"Laurelhurst","offers":[{"title":"Default Title","offer_id":43005621174338,"sku":"DPUIB64","price":195.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1071\/8320\/files\/Screenshot2026-02-17211320.png?v=1771388083"},{"product_id":"uib-24vac-w-fan-control-pins-002-dinosaur","title":"UIB 24VAC Dinosaur (002) W\/FAN CONTROL \u0026 PINS","description":"\u003ch1\u003eUIB 24VAC W\/FAN CONTROL \u0026amp; PINS 002 Dinosaur \u003c\/h1\u003e\n\u003cp\u003e\u003cmeta content=\"text\/html; charset=us-ascii\" http-equiv=\"Content-Type\"\u003e\u003c\/p\u003e\n\u003cstyle\u003e\na {\n    text-decoration: none;\n    color: #464feb;\n}\ntr th, tr td {\n    border: 1px solid #e6e6e6;\n}\ntr th {\n    background-color: #f5f5f5;\n}\n\u003c\/style\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe \u003cstrong\u003eUIB 24VAC with Fan Control \u0026amp; Pins\u003c\/strong\u003e by \u003cstrong\u003eDinosaur Electronics\u003c\/strong\u003e is a universal replacement ignition control board designed for a wide range of residential gas furnaces operating on \u003cstrong\u003e24 VAC control voltage\u003c\/strong\u003e. Engineered as a versatile service replacement, this universal ignition board combines ignition control and fan control functionality into a single module, helping restore reliable furnace operation when OEM control boards fail.\u003c\/p\u003e\n\u003cp\u003eManufactured in the USA by Dinosaur Electronics, the UIB is designed for dependable performance and includes installation pins and hardware to simplify replacement in compatible furnace applications. Its universal design makes it an excellent service inventory item for HVAC contractors seeking a reliable replacement for numerous discontinued or hard-to-find ignition boards.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eCross-Reference\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eUIB\u003c\/li\u003e\n\u003cli\u003eDinosaur UIB\u003c\/li\u003e\n\u003cli\u003eUIB 24VAC\u003c\/li\u003e\n\u003cli\u003eUniversal Ignition Board\u003c\/li\u003e\n\u003cli\u003eDinosaur Electronics Ignition Board\u003c\/li\u003e\n\u003cli\u003eFan Control Ignition Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003ePC 659 PARK MODEL USE \u003c\/span\u003eDPUIBS24VAC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eDirect Replacement\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eUniversal replacement ignition control board\u003c\/strong\u003e for many compatible furnace applications.\u003c\/p\u003e\n\u003cp\u003eAlways verify wiring configuration, ignition type, and furnace compatibility before installation.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eCompatible Brands\u003c\/h2\u003e\n\u003cp\u003eMay be used in compatible applications from:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eColeman\u003c\/li\u003e\n\u003cli\u003eYork\u003c\/li\u003e\n\u003cli\u003eLuxaire\u003c\/li\u003e\n\u003cli\u003eFraser-Johnston\u003c\/li\u003e\n\u003cli\u003eGoodman\u003c\/li\u003e\n\u003cli\u003eAmana\u003c\/li\u003e\n\u003cli\u003eRheem\u003c\/li\u003e\n\u003cli\u003eRuud\u003c\/li\u003e\n\u003cli\u003eCarrier\u003c\/li\u003e\n\u003cli\u003eBryant\u003c\/li\u003e\n\u003cli\u003ePayne\u003c\/li\u003e\n\u003cli\u003eTrane\u003c\/li\u003e\n\u003cli\u003eAmerican Standard\u003c\/li\u003e\n\u003cli\u003eLennox\u003c\/li\u003e\n\u003cli\u003eNordyne\u003c\/li\u003e\n\u003cli\u003eIntertherm\u003c\/li\u003e\n\u003cli\u003eMiller\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAnd many other gas furnace applications utilizing compatible 24VAC ignition controls.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eApplication\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eGas furnaces\u003c\/li\u003e\n\u003cli\u003eResidential HVAC systems\u003c\/li\u003e\n\u003cli\u003eIgnition control replacement\u003c\/li\u003e\n\u003cli\u003eFan control replacement\u003c\/li\u003e\n\u003cli\u003eFurnace repair and service\u003c\/li\u003e\n\u003cli\u003eUniversal retrofit applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eRelated Components\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFlame Sensors\u003c\/li\u003e\n\u003cli\u003eHot Surface Ignitors\u003c\/li\u003e\n\u003cli\u003eSpark Ignitors\u003c\/li\u003e\n\u003cli\u003ePressure Switches\u003c\/li\u003e\n\u003cli\u003eLimit Switches\u003c\/li\u003e\n\u003cli\u003eDraft Inducer Motors\u003c\/li\u003e\n\u003cli\u003eGas Valves\u003c\/li\u003e\n\u003cli\u003eWiring Harnesses\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnician Notes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eUniversal ignition control board with integrated fan control.\u003c\/li\u003e\n\u003cli\u003eDesigned for 24 VAC furnace systems.\u003c\/li\u003e\n\u003cli\u003eIncludes installation pins and mounting hardware.\u003c\/li\u003e\n\u003cli\u003eExcellent replacement option for obsolete OEM ignition boards.\u003c\/li\u003e\n\u003cli\u003eVerify all thermostat, safety, and ignition wiring prior to installation.\u003c\/li\u003e\n\u003cli\u003eFollow Dinosaur Electronics wiring instructions carefully.\u003c\/li\u003e\n\u003cli\u003eInspect all furnace safety controls before condemning the board.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eCommon Symptoms of Failure\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eNo heat operation\u003c\/li\u003e\n\u003cli\u003eFurnace will not ignite\u003c\/li\u003e\n\u003cli\u003eBlower motor not operating correctly\u003c\/li\u003e\n\u003cli\u003eIgnition sequence failures\u003c\/li\u003e\n\u003cli\u003eIntermittent furnace operation\u003c\/li\u003e\n\u003cli\u003eControl board fault conditions\u003c\/li\u003e\n\u003cli\u003eNo response to thermostat call\u003c\/li\u003e\n\u003cli\u003eBurned or damaged circuit board components\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eInstallation Tips\u003c\/h2\u003e\n\u003col\u003e\n\u003cli\u003eDisconnect electrical power before servicing.\u003c\/li\u003e\n\u003cli\u003ePhotograph and label all wiring connections.\u003c\/li\u003e\n\u003cli\u003eVerify compatibility with the furnace ignition system.\u003c\/li\u003e\n\u003cli\u003eTransfer wiring according to Dinosaur Electronics instructions.\u003c\/li\u003e\n\u003cli\u003eSecure the board using the supplied mounting hardware.\u003c\/li\u003e\n\u003cli\u003eInspect safety circuits before startup.\u003c\/li\u003e\n\u003cli\u003eRestore power and verify board diagnostics.\u003c\/li\u003e\n\u003cli\u003eTest the furnace through a complete heating cycle.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003chr\u003e\n\u003ch2\u003eRecommended Inspection Items\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFlame sensor condition\u003c\/li\u003e\n\u003cli\u003eIgnitor operation\u003c\/li\u003e\n\u003cli\u003eGas valve performance\u003c\/li\u003e\n\u003cli\u003ePressure switch operation\u003c\/li\u003e\n\u003cli\u003eHigh-limit switches\u003c\/li\u003e\n\u003cli\u003eDraft inducer motor\u003c\/li\u003e\n\u003cli\u003eThermostat wiring\u003c\/li\u003e\n\u003cli\u003eTransformer voltage\u003c\/li\u003e\n\u003cli\u003eBlower motor operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Laurelhurst","offers":[{"title":"Default Title","offer_id":46135838113858,"sku":"DPUIB24-2","price":159.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1071\/8320\/files\/Screenshot2026-11-22225630.png?v=1795413405"},{"product_id":"41-0050-dpuib-dinosaur-24vac-board-no-fan-001","title":"41-0050 DPUIB DINOSAUR 24VAC BOARD NO FAN 001","description":"\u003ch1\u003e41-0050 DPUIB DINOSAUR 24VAC BOARD NO FAN 001\u003c\/h1\u003e\n\u003cp\u003e\u003cmeta content=\"text\/html; charset=us-ascii\" http-equiv=\"Content-Type\"\u003e\u003c\/p\u003e\n\u003cstyle\u003e\na {\n    text-decoration: none;\n    color: #464feb;\n}\ntr th, tr td {\n    border: 1px solid #e6e6e6;\n}\ntr th {\n    background-color: #f5f5f5;\n}\n\u003c\/style\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe \u003cstrong\u003e41-0050 DPUIB\u003c\/strong\u003e by \u003cstrong\u003eDinosaur Electronics\u003c\/strong\u003e is a universal \u003cstrong\u003e24VAC ignition control board\u003c\/strong\u003e designed as a replacement solution for a wide range of gas furnace ignition systems. Unlike fan-control models, the \u003cstrong\u003eDPUIB (Direct Plug Universal Ignition Board)\u003c\/strong\u003e is specifically designed for applications where the furnace's blower or fan functions are controlled separately. Engineered for reliability and ease of installation, this universal board helps restore proper ignition sequencing, burner operation, and furnace safety monitoring when OEM ignition modules fail.\u003c\/p\u003e\n\u003cp\u003eManufactured in the USA by Dinosaur Electronics, the DPUIB is known for its rugged construction, diagnostic capability, and broad compatibility with many furnace brands and ignition systems.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eCross-Reference\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e41-0050\u003c\/li\u003e\n\u003cli\u003eDPUIB\u003c\/li\u003e\n\u003cli\u003eDinosaur DPUIB\u003c\/li\u003e\n\u003cli\u003eDinosaur Electronics DPUIB\u003c\/li\u003e\n\u003cli\u003e24VAC Universal Ignition Board\u003c\/li\u003e\n\u003cli\u003eUniversal Furnace Ignition Module\u003c\/li\u003e\n\u003cli\u003eIgnition Control Board\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eDirect Replacement\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eUniversal replacement ignition board\u003c\/strong\u003e for many compatible gas furnace applications.\u003c\/p\u003e\n\u003cp\u003eAlways verify ignition type, wiring configuration, and furnace compatibility before installation.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eCompatible Brands\u003c\/h2\u003e\n\u003cp\u003eMay be used in compatible applications from:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eColeman\u003c\/li\u003e\n\u003cli\u003eYork\u003c\/li\u003e\n\u003cli\u003eLuxaire\u003c\/li\u003e\n\u003cli\u003eFraser-Johnston\u003c\/li\u003e\n\u003cli\u003eGoodman\u003c\/li\u003e\n\u003cli\u003eAmana\u003c\/li\u003e\n\u003cli\u003eRheem\u003c\/li\u003e\n\u003cli\u003eRuud\u003c\/li\u003e\n\u003cli\u003eCarrier\u003c\/li\u003e\n\u003cli\u003eBryant\u003c\/li\u003e\n\u003cli\u003ePayne\u003c\/li\u003e\n\u003cli\u003eLennox\u003c\/li\u003e\n\u003cli\u003eNordyne\u003c\/li\u003e\n\u003cli\u003eIntertherm\u003c\/li\u003e\n\u003cli\u003eMiller\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAnd many other furnaces utilizing compatible 24VAC ignition control systems.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eApplication\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eGas furnaces\u003c\/li\u003e\n\u003cli\u003eResidential HVAC systems\u003c\/li\u003e\n\u003cli\u003eIgnition control replacement\u003c\/li\u003e\n\u003cli\u003eFurnace repair applications\u003c\/li\u003e\n\u003cli\u003eUniversal retrofit projects\u003c\/li\u003e\n\u003cli\u003eService vehicle stock inventory\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eRelated Components\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFlame Sensors\u003c\/li\u003e\n\u003cli\u003eHot Surface Ignitors\u003c\/li\u003e\n\u003cli\u003eSpark Ignitors\u003c\/li\u003e\n\u003cli\u003ePressure Switches\u003c\/li\u003e\n\u003cli\u003eLimit Switches\u003c\/li\u003e\n\u003cli\u003eDraft Inducer Motors\u003c\/li\u003e\n\u003cli\u003eGas Valves\u003c\/li\u003e\n\u003cli\u003eWiring Harnesses\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnician Notes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eGenuine Dinosaur Electronics universal ignition board.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e24 VAC operation.\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eNo integrated fan control.\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eDesigned for systems with separate blower control circuits.\u003c\/li\u003e\n\u003cli\u003eDirect Plug Universal Ignition Board (DPUIB) design.\u003c\/li\u003e\n\u003cli\u003eExcellent replacement for obsolete ignition modules.\u003c\/li\u003e\n\u003cli\u003eVerify thermostat, safety, and ignition wiring prior to installation.\u003c\/li\u003e\n\u003cli\u003eFollow Dinosaur Electronics wiring and setup instructions during replacement.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eCommon Symptoms of Failure\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFurnace will not ignite\u003c\/li\u003e\n\u003cli\u003eNo heat operation\u003c\/li\u003e\n\u003cli\u003eIgnition sequence failure\u003c\/li\u003e\n\u003cli\u003eIntermittent burner operation\u003c\/li\u003e\n\u003cli\u003eIgnition lockouts\u003c\/li\u003e\n\u003cli\u003eNo response to thermostat calls\u003c\/li\u003e\n\u003cli\u003eDiagnostic fault conditions\u003c\/li\u003e\n\u003cli\u003eBurned or damaged control board components\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eInstallation Tips\u003c\/h2\u003e\n\u003col\u003e\n\u003cli\u003eDisconnect electrical power before servicing.\u003c\/li\u003e\n\u003cli\u003ePhotograph and label all wiring connections.\u003c\/li\u003e\n\u003cli\u003eVerify compatibility with the furnace ignition system.\u003c\/li\u003e\n\u003cli\u003eTransfer wiring according to Dinosaur Electronics instructions.\u003c\/li\u003e\n\u003cli\u003eMount the board securely using supplied hardware.\u003c\/li\u003e\n\u003cli\u003eInspect all safety circuits before startup.\u003c\/li\u003e\n\u003cli\u003eRestore power and verify diagnostic operation.\u003c\/li\u003e\n\u003cli\u003eTest the furnace through a complete heating cycle.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003chr\u003e\n\u003ch2\u003eRecommended Inspection Items\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFlame sensor condition\u003c\/li\u003e\n\u003cli\u003eIgnitor operation\u003c\/li\u003e\n\u003cli\u003eGas valve function\u003c\/li\u003e\n\u003cli\u003ePressure switch operation\u003c\/li\u003e\n\u003cli\u003eHigh-limit controls\u003c\/li\u003e\n\u003cli\u003eDraft inducer motor\u003c\/li\u003e\n\u003cli\u003eTransformer voltage\u003c\/li\u003e\n\u003cli\u003eThermostat wiring\u003c\/li\u003e\n\u003cli\u003eFurnace safety circuits\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Laurelhurst","offers":[{"title":"Default Title","offer_id":46135990190146,"sku":"DPUIB 24","price":159.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1071\/8320\/files\/Screenshot2026-11-22230616.png?v=1795413990"},{"product_id":"uibl-p-dinosaur-12v-long-board-w-post","title":"UIBL-P Dinosaur 12V LONG BOARD W\/POST","description":"\u003ch1\u003eUIBL-P Dinosaur 12V LONG BOARD W\/POST\u003c\/h1\u003e\n\u003cp\u003e\u003cmeta content=\"text\/html; charset=us-ascii\" http-equiv=\"Content-Type\"\u003e\u003c\/p\u003e\n\u003cstyle\u003e\na {\n    text-decoration: none;\n    color: #464feb;\n}\ntr th, tr td {\n    border: 1px solid #e6e6e6;\n}\ntr th {\n    background-color: #f5f5f5;\n}\n\u003c\/style\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe \u003cstrong\u003eUIBL-P Dinosaur Electronics Long Board\u003c\/strong\u003e is a premium \u003cstrong\u003e12-volt DC universal ignition control board\u003c\/strong\u003e designed for RV furnaces and mobile heating systems. Featuring a \u003cstrong\u003elong-board configuration with post-style terminals\u003c\/strong\u003e, the \u003cstrong\u003eUIBL-P\u003c\/strong\u003e provides a durable and reliable replacement solution for a variety of OEM RV furnace ignition boards. Designed and manufactured by \u003cstrong\u003eDinosaur Electronics\u003c\/strong\u003e, this board is known for its robust construction, advanced diagnostics, and dependable performance in demanding RV environments.\u003c\/p\u003e\n\u003cp\u003eThe UIBL-P controls critical furnace functions including ignition sequencing, flame sensing, safety lockout protection, and burner operation, helping restore reliable heating performance in travel trailers, fifth wheels, motorhomes, and other RV applications.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eCross-Reference\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eUIBL-P\u003c\/li\u003e\n\u003cli\u003eUIBLP\u003c\/li\u003e\n\u003cli\u003eDinosaur UIBL-P\u003c\/li\u003e\n\u003cli\u003eDinosaur Electronics UIBL-P\u003c\/li\u003e\n\u003cli\u003eUniversal Ignition Board Long\u003c\/li\u003e\n\u003cli\u003e12V RV Furnace Control Board\u003c\/li\u003e\n\u003cli\u003eLong Board with Posts\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eDirect Replacement\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eUniversal replacement ignition board\u003c\/strong\u003e for many compatible RV furnace applications.\u003c\/p\u003e\n\u003cp\u003eAlways verify terminal style, wiring configuration, and furnace compatibility before installation.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eCompatible Brands\u003c\/h2\u003e\n\u003cp\u003eCompatible with many RV furnace systems, including select models from:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAtwood\u003c\/li\u003e\n\u003cli\u003eHydro Flame\u003c\/li\u003e\n\u003cli\u003eDometic\u003c\/li\u003e\n\u003cli\u003eSuburban\u003c\/li\u003e\n\u003cli\u003eDuo-Therm\u003c\/li\u003e\n\u003cli\u003eEverest Star\u003c\/li\u003e\n\u003cli\u003eOther compatible 12V RV furnace applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eVerify furnace model compatibility before ordering.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eApplication\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRV furnaces\u003c\/li\u003e\n\u003cli\u003eTravel trailer heating systems\u003c\/li\u003e\n\u003cli\u003eFifth wheel furnaces\u003c\/li\u003e\n\u003cli\u003eMotorhome furnaces\u003c\/li\u003e\n\u003cli\u003eMobile heating systems\u003c\/li\u003e\n\u003cli\u003e12V ignition control applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eRelated Components\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSail Switches\u003c\/li\u003e\n\u003cli\u003eFlame Sensors\u003c\/li\u003e\n\u003cli\u003eIgniters\u003c\/li\u003e\n\u003cli\u003eLimit Switches\u003c\/li\u003e\n\u003cli\u003eBlower Motors\u003c\/li\u003e\n\u003cli\u003eGas Valves\u003c\/li\u003e\n\u003cli\u003eThermostats\u003c\/li\u003e\n\u003cli\u003eWiring Harnesses\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnician Notes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eGenuine Dinosaur Electronics replacement board.\u003c\/li\u003e\n\u003cli\u003e12 VDC operation.\u003c\/li\u003e\n\u003cli\u003eLong-board design with post terminals.\u003c\/li\u003e\n\u003cli\u003eDesigned specifically for RV furnace applications.\u003c\/li\u003e\n\u003cli\u003eControls ignition sequence, flame verification, and safety shutdown functions.\u003c\/li\u003e\n\u003cli\u003eKnown for improved reliability compared to many original equipment boards.\u003c\/li\u003e\n\u003cli\u003eVerify proper furnace grounding before replacing the control board.\u003c\/li\u003e\n\u003cli\u003eInspect sail switch, limit switch, and igniter operation when diagnosing board failures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eCommon Symptoms of Failure\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFurnace will not ignite\u003c\/li\u003e\n\u003cli\u003eNo heat operation\u003c\/li\u003e\n\u003cli\u003eIgnition lockout conditions\u003c\/li\u003e\n\u003cli\u003eBlower runs without burner ignition\u003c\/li\u003e\n\u003cli\u003eIntermittent furnace operation\u003c\/li\u003e\n\u003cli\u003eNo response to thermostat demand\u003c\/li\u003e\n\u003cli\u003eFlame sensing faults\u003c\/li\u003e\n\u003cli\u003eBurned or damaged control board components\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eInstallation Tips\u003c\/h2\u003e\n\u003col\u003e\n\u003cli\u003eDisconnect 12V DC power before servicing.\u003c\/li\u003e\n\u003cli\u003eLabel all wire locations before removing the original board.\u003c\/li\u003e\n\u003cli\u003eVerify compatibility with the furnace model.\u003c\/li\u003e\n\u003cli\u003eTransfer wiring to the new board one connection at a time.\u003c\/li\u003e\n\u003cli\u003eInspect terminal ends and connectors for corrosion.\u003c\/li\u003e\n\u003cli\u003eConfirm proper grounding and power supply voltage.\u003c\/li\u003e\n\u003cli\u003eRestore power and test furnace operation.\u003c\/li\u003e\n\u003cli\u003eVerify proper ignition, flame sensing, and blower operation.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003chr\u003e\n\u003ch2\u003eRecommended Inspection Items\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSail switch condition\u003c\/li\u003e\n\u003cli\u003eIgniter operation\u003c\/li\u003e\n\u003cli\u003eFlame sensor circuit\u003c\/li\u003e\n\u003cli\u003eGas valve performance\u003c\/li\u003e\n\u003cli\u003eBlower motor operation\u003c\/li\u003e\n\u003cli\u003eThermostat wiring\u003c\/li\u003e\n\u003cli\u003eGround connections\u003c\/li\u003e\n\u003cli\u003eFurnace heat exchanger\u003c\/li\u003e\n\u003cli\u003e12V DC power supply\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Laurelhurst","offers":[{"title":"Default Title","offer_id":46150419185730,"sku":"DPUIBL-P","price":139.85,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1071\/8320\/files\/Screenshot2026-11-23112804.png?v=1795458497"},{"product_id":"uibs-dinosaur-uibs-12v-short-board-w-spade","title":"UIBS Dinosaur UIBS 12V SHORT BOARD W\/SPADE","description":"\u003ch1\u003eUIBS Dinosaur UIBS 12V SHORT BOARD W\/SPADE\u003c\/h1\u003e\n\u003cp\u003eReplaces: \u003cspan\u003e39-0400\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cmeta content=\"text\/html; charset=us-ascii\" http-equiv=\"Content-Type\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cstyle\u003e\na {\n    text-decoration: none;\n    color: #464feb;\n}\ntr th, tr td {\n    border: 1px solid #e6e6e6;\n}\ntr th {\n    background-color: #f5f5f5;\n}\n\u003c\/style\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe \u003cstrong\u003eUIBS Dinosaur Electronics Universal Ignition Board\u003c\/strong\u003e is a premium \u003cstrong\u003e12-volt DC replacement furnace control board\u003c\/strong\u003e designed specifically for RV and mobile heating applications. Featuring a compact \u003cstrong\u003eshort-board design\u003c\/strong\u003e with \u003cstrong\u003espade terminal connections\u003c\/strong\u003e, the UIBS provides a reliable replacement solution for many OEM RV furnace ignition boards. Manufactured in the USA by \u003cstrong\u003eDinosaur Electronics\u003c\/strong\u003e, this board is known for superior durability, enhanced diagnostics, and dependable operation in demanding RV environments.\u003c\/p\u003e\n\u003cp\u003eThe UIBS controls critical furnace functions including ignition sequencing, flame sensing, burner operation, and safety lockout protection. Its compact footprint makes it ideal for installations where space is limited while maintaining compatibility with a wide range of RV furnace systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eReplaces: 39-0400\u003c\/strong\u003e\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eCross-Reference\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eUIBS\u003c\/li\u003e\n\u003cli\u003eDinosaur UIBS\u003c\/li\u003e\n\u003cli\u003e39-0400\u003c\/li\u003e\n\u003cli\u003eDinosaur Electronics 39-0400\u003c\/li\u003e\n\u003cli\u003eUniversal Ignition Board Short\u003c\/li\u003e\n\u003cli\u003eRV Furnace Control Board\u003c\/li\u003e\n\u003cli\u003e12V Ignition Control Board\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eDirect Replacement\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eReplaces:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e39-0400\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eGenuine Dinosaur Electronics replacement ignition board.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eCompatible Brands\u003c\/h2\u003e\n\u003cp\u003eCompatible with many RV furnace applications including:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAtwood\u003c\/li\u003e\n\u003cli\u003eHydro Flame\u003c\/li\u003e\n\u003cli\u003eDometic\u003c\/li\u003e\n\u003cli\u003eSuburban\u003c\/li\u003e\n\u003cli\u003eDuo-Therm\u003c\/li\u003e\n\u003cli\u003eEverest Star\u003c\/li\u003e\n\u003cli\u003eOther compatible 12V RV furnace systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAlways verify furnace model and board configuration before ordering.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eApplication\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eRV furnaces\u003c\/li\u003e\n\u003cli\u003eTravel trailer heating systems\u003c\/li\u003e\n\u003cli\u003eFifth wheel furnaces\u003c\/li\u003e\n\u003cli\u003eMotorhome furnace systems\u003c\/li\u003e\n\u003cli\u003eMobile heating equipment\u003c\/li\u003e\n\u003cli\u003e12V ignition control applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eRelated Components\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSail Switches\u003c\/li\u003e\n\u003cli\u003eFlame Sensors\u003c\/li\u003e\n\u003cli\u003eIgniters\u003c\/li\u003e\n\u003cli\u003eLimit Switches\u003c\/li\u003e\n\u003cli\u003eBlower Motors\u003c\/li\u003e\n\u003cli\u003eGas Valves\u003c\/li\u003e\n\u003cli\u003eThermostats\u003c\/li\u003e\n\u003cli\u003eWiring Harnesses\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnician Notes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eGenuine Dinosaur Electronics replacement board.\u003c\/li\u003e\n\u003cli\u003e12 VDC operation.\u003c\/li\u003e\n\u003cli\u003eCompact short-board configuration.\u003c\/li\u003e\n\u003cli\u003eSpade terminal connections for simplified installation.\u003c\/li\u003e\n\u003cli\u003eControls ignition sequence and flame verification functions.\u003c\/li\u003e\n\u003cli\u003eProvides safety shutdown and lockout protection.\u003c\/li\u003e\n\u003cli\u003eExcellent upgrade for aging OEM furnace boards.\u003c\/li\u003e\n\u003cli\u003eVerify proper grounding and battery voltage during troubleshooting.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eCommon Symptoms of Failure\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFurnace will not ignite\u003c\/li\u003e\n\u003cli\u003eNo heat operation\u003c\/li\u003e\n\u003cli\u003eIgnition lockout conditions\u003c\/li\u003e\n\u003cli\u003eBlower operates without burner ignition\u003c\/li\u003e\n\u003cli\u003eIntermittent furnace operation\u003c\/li\u003e\n\u003cli\u003eNo response to thermostat demand\u003c\/li\u003e\n\u003cli\u003eFlame sensing faults\u003c\/li\u003e\n\u003cli\u003eBurned or damaged board components\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eInstallation Tips\u003c\/h2\u003e\n\u003col\u003e\n\u003cli\u003eDisconnect 12V DC power before servicing.\u003c\/li\u003e\n\u003cli\u003eLabel all wiring before removing the existing board.\u003c\/li\u003e\n\u003cli\u003eVerify compatibility with the furnace model.\u003c\/li\u003e\n\u003cli\u003eTransfer wires one connection at a time.\u003c\/li\u003e\n\u003cli\u003eInspect spade terminals for corrosion or overheating.\u003c\/li\u003e\n\u003cli\u003eVerify proper furnace grounding.\u003c\/li\u003e\n\u003cli\u003eRestore power and test ignition operation.\u003c\/li\u003e\n\u003cli\u003eConfirm proper burner ignition and safety shutdown functions.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003chr\u003e\n\u003ch2\u003eRecommended Inspection Items\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSail switch operation\u003c\/li\u003e\n\u003cli\u003eIgniter condition\u003c\/li\u003e\n\u003cli\u003eFlame sensing circuit\u003c\/li\u003e\n\u003cli\u003eGas valve operation\u003c\/li\u003e\n\u003cli\u003eBlower motor performance\u003c\/li\u003e\n\u003cli\u003eThermostat function\u003c\/li\u003e\n\u003cli\u003eGround connections\u003c\/li\u003e\n\u003cli\u003eHeat exchanger condition\u003c\/li\u003e\n\u003cli\u003eBattery voltage supply\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Laurelhurst","offers":[{"title":"Default Title","offer_id":46150818234434,"sku":"DPUIBS","price":129.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1071\/8320\/files\/Screenshot2026-11-23113714.png?v=1795459047"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1071\/8320\/collections\/Screenshot_2026-11-23_115926.png?v=1795460628","url":"https:\/\/hvacpartstoremarket.com\/collections\/dinosaur-electronics-rv-aftermarket-controls.oembed","provider":"HVACpartstore","version":"1.0","type":"link"}