{"title":"7665 Coleman Parts Breakdown","description":"\u003cdiv style=\"text-align: left;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1071\/8320\/files\/7000_Series_Coleman_Parts_JPEG_Page_18_1024x1024.jpg?v=1750301165\" alt=\"7655, 7665, 7670, 7680\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1071\/8320\/files\/7000_Series_Coleman_Parts_JPEG_Page_03_1024x1024.jpg?v=1750302001\" alt=\"7655, 7665, 7670, 7680\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1071\/8320\/files\/7000_Series_Coleman_Parts_JPEG_Page_02_1024x1024.jpg?v=1750302016\" alt=\"7655, 7665, 7670, 7680\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1071\/8320\/files\/7000_Series_Coleman_Parts_JPEG_Page_25_1024x1024.jpg?v=1750302031\" alt=\"7655, 7665, 7670, 7680\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/div\u003e","products":[{"product_id":"s1-7956-336p-york-coleman-oem-gas-valve-1-year-warranty-24v-lp-nat-1-2-npt","title":"S1-7956-336P York\/ Coleman OEM Gas Valve 1 year warranty 24V LP \u0026 NAT 1\/2\" NPT","description":"\u003ch1\u003eS1-7956-336P York\/ Coleman OEM Gas Valve 1 year warranty 24V LP \u0026amp; NAT 1\/2\" NPT\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan style=\"background-color: rgb(255, 255, 0);\"\u003eNormal Stocking Item ready to ship \u003c\/span\u003e\u003c\/h2\u003e\n\u003ch2\u003e1 year warranty\u003c\/h2\u003e\n\u003cp\u003eGas valve used on many Coleman furnaces with a standing pilot light. This valve may not look like your original valve, but it's the new Coleman style. Comes set for natural gas, but can be converted for propane use with no additional parts required (see video below). 1\/2\" gas inlet on right, 3\/8\" outlet on back. A new \u003ca title=\"https:\/\/colemanhvacparts.com\/products\/2631-3481-coleman-thermocouple-24?_pos=1\u0026amp;_sid=7b95287f3\u0026amp;_ss=r\" href=\"https:\/\/colemanhvacparts.com\/products\/2631-3481-coleman-thermocouple-24?_pos=1\u0026amp;_sid=7b95287f3\u0026amp;_ss=r\"\u003e2631-3481\u003c\/a\u003e thermocouple recommended (sold separately). \u003cspan style=\"background-color: #ffff00;\"\u003eMounting bracket number \u003ca title=\"https:\/\/colemanhvacparts.com\/products\/s1-7705-5101?_pos=1\u0026amp;_sid=0411e93d4\u0026amp;_ss=r\" href=\"https:\/\/colemanhvacparts.com\/products\/s1-7705-5101?_pos=1\u0026amp;_sid=0411e93d4\u0026amp;_ss=r\"\u003e7705-5101\u003c\/a\u003e (sold separately) is required when mounting this gas valve on older 7600, 7900 series Coleman gas furnaces.\u003c\/span\u003e Discard the old bracket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eReplaces\u003c\/strong\u003e 36C67, 36C87, 7656-356, 7656-3561, 7656A346, 7656A3461, 7956-336, 7956-3361, 7656-326, 7656-3261, 7656A326, 7656A3261, 7656-346, 7656-3461, 7660-326, 7660-3261, 7680-346, 7680-3461, 7631A326, and 7631A3261. Used as a replacement for Intertherm 6240603 and Duo-Therm 3-3226, 3-3226-1 \u0026amp; H-3226. When using on a Duo-Therm furnace, a 5\" or 2.5\" black nipple pipe 1\/2\" diameter may be required for hook-up.\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"background-color: #ffff00;\"\u003e Watch our 2-minute video below to see how the gas conversion is done.\u003c\/span\u003e\u003cbr\u003e\u003ca title=\"https:\/\/youtu.be\/TARwavd1IJs\" href=\"https:\/\/youtu.be\/TARwavd1IJs\"\u003ehttps:\/\/youtu.be\/TARwavd1IJs\u003c\/a\u003e\u003cbr\u003e\u003cbr\u003e7200ERCS\u003c\/p\u003e\n\u003ch3 class=\"classyunicodedone\"\u003eYork Coleman S1-7956-336P Replacement Part\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIncludes:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e(1) - Gas Valve (S1-7956-336P)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eReplaces Old York Coleman Part Numbers\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eS1-7656A3461\u003c\/li\u003e\n\u003cli\u003eS1-7680-3461\u003c\/li\u003e\n\u003cli\u003eS1-7656-3261\u003c\/li\u003e\n\u003cli\u003eS1-7660-3261\u003c\/li\u003e\n\u003cli\u003eS1-7656-3561\u003c\/li\u003e\n\u003cli\u003eS1-7956-3361\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOther Part Numbers\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFits Models:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e(Press ctrl + F to find model number below.)\u003c\/p\u003e\n\u003cp\u003e7956-759\/D, 7956-759\/E, 7956-856\/D, 7956-856\/E, 7970-759\/E, 7970-856\/E, 7975-759\/E, 7975-856\/E, DGPA056ABTA, DGPA056ABTA, DGPA056ABTA, DGPA070ABTA, DGPA070ABTA, DGPA070ABTA, DGPA077ABTA, DGPA077ABTA, DGPA077ABTA, DGPA090ABTA, DGPA090ABTA, DGPA090ABTA, DGPH056ABTA, DGPH056ABTA, DGPH056ABTA, DGPH070ABTA, DGPH070ABTA, DGPH070ABTA, DGPH077ABTA, DGPH077ABTA, DGPH077ABTA, DGPH090ABTA, DGPH090ABTA, DGPH090ABTA, DGPT056ADA, DGPT066ADA, DGRM056AUA, DGRM056AUB, DGRM075AUA, DGRM075AUB, DGRT056AUA, DGRT056AUB, DGRT070AUA, DGRT070AUB, DGRT075AUA, DGRT075AUB, DLRS056AUA, DLRS056AUB, DLRS070AUA, DLRS070AUB, DLRS075AUA, DLRS075AUB\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv align=\"center\"\u003e\n\u003cobject width=\"320\" height=\"265\"\u003e\u003cparam name=\"movie\" value=\"http:\/\/www.youtube.com\/v\/TARwavd1IJs\u0026amp;hl=en_US\u0026amp;fs=1\u0026amp;\"\u003e\n\u003cparam name=\"allowFullScreen\" value=\"true\"\u003e\n\u003cparam name=\"allowscriptaccess\" value=\"always\"\u003e\n\u003cembed src=\"\/\/www.youtube.com\/v\/TARwavd1IJs\u0026amp;hl=en_US\u0026amp;fs=1\u0026amp;\" type=\"application\/x-shockwave-flash\" allowscriptaccess=\"always\" allowfullscreen=\"true\" width=\"320\" height=\"265\" title=\"Adobe Flash Player\"\u003e\u003c\/object\u003e\u003cbr\u003e\n\u003c\/div\u003e","brand":"Quinn","offers":[{"title":"Default Title","offer_id":13114304131,"sku":"7956-336P","price":528.23,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1071\/8320\/products\/7956-336p-coleman-gas-valve-15.jpeg?v=1566073108"},{"product_id":"s1-7675-348-coleman-oem-replacement-thermocouple-24","title":"S1-7675-348 Coleman OEM Replacement thermocouple 24\",","description":"\u003ch1\u003eS1-7675-348 Coleman OEM Replacement Thermocouple 24\", 2631-3481\u003c\/h1\u003e\n\u003ch3\u003e\u003cspan style=\"background-color: rgb(255, 255, 0);\"\u003eNormal Stock Item\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eReplaces\u003c\/strong\u003e: 2631-3481, 7675-348, S1-7675-3481\u003c\/p\u003e\n\u003ch2\u003e\u003cspan style=\"background-color: rgb(255, 255, 0);\"\u003eFor the Older Model Mobile \/ Modular Home Furnace OEM Part With Standing Pilot\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"background-color: rgb(255, 255, 0);\"\u003eSpecially made for older Coleman equipment 30.2mv 24\"\u003c\/span\u003e and works awesome with the Coleman Gas valves 1 year warranty, don't be fooled by the knockoff's cheap universal thermocouples that may last for a few months but doesn't match the 30mv supply that could damage the gas valve, Buy OEM and keep your Coleman Furnace running for years to come. \u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2 id=\"part-num\"\u003e\u003cspan style=\"background-color: rgb(255, 255, 0);\"\u003e\u003cstrong\u003eNormal Stocking Item 26\/27 Heating Season \u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch2\u003e\u003cspan style=\"background-color: rgb(255, 255, 0);\"\u003e\u003cstrong\u003eColeman Mobile Home Product\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan\u003eThe OEM 2631-3481 is \u003cstrong\u003especifically tuned to Colemans 30mV gas valves\u003c\/strong\u003e. Universal thermocouples often output lower or unstable millivolt levels, which can:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul role=\"list\"\u003e\n\u003cli\u003e\n\u003ch3\u003e\u003cspan\u003ecause pilot dropout\u003c\/span\u003e\u003c\/h3\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ch3\u003e\u003cspan\u003edamage the gas valve\u003c\/span\u003e\u003c\/h3\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ch3\u003e\u003cspan\u003ecreate intermittent heat calls\u003c\/span\u003e\u003c\/h3\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnician Notes\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul role=\"list\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOEM is strongly preferred Coleman gas valves require a \u003cstrong\u003estable 30mV\u003c\/strong\u003e signal.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eReplace if pilot will not stay lit, drops out intermittently, or gas valve fails to hold open.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eInspect pilot flame: should be \u003cstrong\u003eblue, stable, and fully engulfing the thermocouple tip\u003c\/strong\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAlways tighten compression nut snugly do not overtighten.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eIdentity \u0026amp; Function\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul role=\"list\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003ePart Numbers:\u003c\/strong\u003e 2631-3481, S1-7675-348\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eLength:\u003c\/strong\u003e 24\"\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMillivolt Output:\u003c\/strong\u003e \u003cstrong\u003e30-mV\u003c\/strong\u003e (critical for Coleman gas valves)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eType:\u003c\/strong\u003e Continuous pilot thermocouple\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMaterial:\u003c\/strong\u003e Copper with brass fittings\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eConnection:\u003c\/strong\u003e Standard threaded pilot burner nut\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e Older Coleman mobile\/modular home furnaces with standing pilot ignition\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eWarranty:\u003c\/strong\u003e 1 year OEM warranty \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eFunction:\u003c\/strong\u003e Senses pilot flame → generates 30-mV signal → keeps gas valve open. If flame is lost signal drops gas valve closes for safety. \u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\n\u003ch2 id=\"part-num\"\u003e\u003c\/h2\u003e\n\u003c\/div\u003e\n\u003ch3\u003e Compatibility\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eFits\u003c\/strong\u003e: Coleman mobile home and residential gas furnaces with continuous pilot systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eCommon Units\u003c\/strong\u003e: 7956A856, 7966A856, 7970A856, 7975A856, 7995A856, 8631A\/B\/C, 8632A\/B\/C, 8638A\/B\/C, and others using pilot ignition\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eIgnition Type\u003c\/strong\u003e: Compatible with standing pilot assemblies not for spark or hot surface ignition systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e: Universal fit for most Coleman pilot burners with 24\" reach\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cstrong\u003eWarranty: \u003c\/strong\u003e1 year warranty\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e2631-3481 \/ S1-7675-348 Coleman OEM 24\" Thermocouple 30-¯mV standing pilot flame sensor for older Coleman mobile and modular home furnaces. Specially engineered for Coleman gas valves to deliver the correct millivolt signal for safe, reliable operation. Copper\/brass OEM construction ensures long life and stable pilot performance. Direct fit replacement for legacy Coleman furnace families including 7956, 7966, 7970, 7975, 7995, and 8631\/8632\/8638 series.\u003c\/h3\u003e\n\u003ch3\u003eReplacement \u0026amp; Cross-Reference Part Numbers\u003c\/h3\u003e\n\u003ch3\u003eDuo-therm number 714072-001\u003c\/h3\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eOEM Part Number\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003cth\u003eNotes\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e2631-3481\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOriginal OEM part\u003c\/td\u003e\n\u003ctd\u003e24\" thermocouple, brass nut\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eS1-7675-348\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYork\/Coleman alternate\u003c\/td\u003e\n\u003ctd\u003eSame specs, different packaging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cstrong\u003e2631-347\u003c\/strong\u003e, \u003cstrong\u003e2631-3471\u003c\/strong\u003e, \u003cstrong\u003e2631-348\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003ctd\u003eLegacy Coleman numbers\u003c\/td\u003e\n\u003ctd\u003eInterchangeable with 2631-3481\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e026-34038-000\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOlder York\/Coleman part\u003c\/td\u003e\n\u003ctd\u003eOften replaced by 2631-3481\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e631132\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMiller equivalent\u003c\/td\u003e\n\u003ctd\u003eSame length and thread, cross-compatible in some mobile home units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"keywords\"\u003e\n\u003ch4\u003eDescription\u003c\/h4\u003e\n\u003cdiv id=\"description\"\u003e\u003cstrong\u003eThermocouple\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eReplacement Coleman 24\" thermocouple senses pilot light and closes gas valve if no flame sensed. Used in most all furnaces with a pilot light.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eReplaces 2631-347, 2631-3471, 2631-348, 2631-3481, 7675-3481, 026-34038-000, S1-7675-348, Q340A1074, 10P27, K17AT-24H, P671-0024, S1-2631-3481\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eFunction \u0026amp; Application\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThis thermocouple generates a small electrical signal when heated by the pilot flame. That signal keeps the gas valve open. If the pilot goes out, the thermocouple cools and shuts off gas flow to prevent unsafe conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eA failing thermocouple can cause:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePilot not staying lit\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFurnace not firing\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIntermittent heating\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePilot outages during windy or cold conditions\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eReplacing it restores reliable pilot operation.\u003c\/span\u003e\u003c\/p\u003e","brand":"Quinn","offers":[{"title":"Default Title","offer_id":13291395843,"sku":"S1-2631-3481","price":44.92,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1071\/8320\/products\/7675-348.jpg?v=1582003086"},{"product_id":"blend-air-blend-air-deluxe-ii-manual-trouble-shoot-guide-parts-breakdown","title":"Blend Air \u0026 Blend Air Deluxe II Manual, Trouble Shoot Guide, Parts Breakdown","description":"\u003ch1\u003e\u003cstrong\u003eBlend Air \u0026amp; Blend Air Deluxe II Manual, Trouble Shoot Guide, Parts Breakdown (Download) For Models 7681-8171, 7681-8171\/A, 7681-8171\/B, 7681-8191, 7681-8191\/A\u003c\/strong\u003e\u003c\/h1\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003e23 pages of information everything from A to Z on the Blend Air Systems\u003c\/strong\u003e\u003c\/h3\u003e","brand":"HVAC Part Store","offers":[{"title":"Default Title","offer_id":32606547378242,"sku":"Blend Air","price":5.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1071\/8320\/products\/BlendPDF.jpg?v=1739517554"},{"product_id":"7660-3661-coleman-oem-observation-burner-cap-with-fire-glass-and-gasket","title":"7660-3661 Coleman OEM Observation Burner Cap With Fire Glass and Gasket","description":"\u003ch1\u003e7660-3661 Coleman OEM Observation Burner Cap With Fire Glass and Gasket\u003c\/h1\u003e\n\u003ch1\u003e\u003cspan style=\"background-color: rgb(255, 255, 0);\"\u003e(Complete Kit)\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp\u003e\u003cmeta content=\"text\/html; charset=us-ascii\" http-equiv=\"Content-Type\"\u003e\u003c\/p\u003e\n\u003cstyle\u003e\na {\n    text-decoration: none;\n    color: #464feb;\n}\ntr th, tr td {\n    border: 1px solid #e6e6e6;\n}\ntr th {\n    background-color: #f5f5f5;\n}\n\u003c\/style\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe \u003cstrong\u003e7660-3661 Coleman Observation Burner Cap\u003c\/strong\u003e is a genuine OEM replacement assembly designed for select Coleman, York, Luxaire, and Fraser-Johnston gas furnaces. This burner observation cap includes the \u003cstrong\u003ehigh-temperature fire glass viewing window\u003c\/strong\u003e and \u003cstrong\u003ereplacement gasket\u003c\/strong\u003e, allowing technicians to safely inspect burner operation and flame characteristics while maintaining proper combustion chamber sealing.\u003c\/p\u003e\n\u003cp\u003eManufactured to original equipment specifications, the 7660-3661 provides a direct-fit replacement for damaged, cracked, missing, or deteriorated observation covers. The included fire glass and gasket help ensure safe furnace operation, proper combustion performance, and reliable burner compartment integrity.\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eParts Breakdown for the\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch1 class=\"h2\" itemprop=\"name\"\u003e7660-3661\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan\u003e\u003cstrong\u003eFireproof Round Glass Part\u003c\/strong\u003e \u003cstrong\u003e#\u003ca href=\"https:\/\/hvacpartstoremarket.com\/products\/sg-511-fire-rated-sight-glass-circle-1-1-2-round-1-8-thick?_pos=1\u0026amp;_sid=89f86cc06\u0026amp;_ss=r\"\u003eSG-511\u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch2\u003e\u003cspan\u003e\u003cstrong\u003eGasket Only part # \u003ca href=\"https:\/\/hvacpartstoremarket.com\/products\/2943700-746-dometic-thermistor-kit?_pos=972\u0026amp;_sid=67e17bd8f\u0026amp;_ss=r\"\u003eG-181\u003c\/a\u003e.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch2\u003e\u003cspan\u003e\u003cstrong\u003eCap Only Part # \u003ca href=\"https:\/\/hvacpartstoremarket.com\/products\/7660-cap-for-sight-glass?_pos=1\u0026amp;_sid=4cc6d6741\u0026amp;_ss=r\"\u003e7660-Cap\u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003chr\u003e\n\u003ch2\u003eCross-Reference\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e7660-3661\u003c\/li\u003e\n\u003cli\u003eColeman 7660-3661\u003c\/li\u003e\n\u003cli\u003eObservation Burner Cap\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"h2\" itemprop=\"name\"\u003e7660-Cap for Sight Glass\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003eBurner Inspection Window\u003c\/li\u003e\n\u003cli\u003eFire Glass Assembly\u003c\/li\u003e\n\u003cli\u003eBurner Viewing Port\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eDirect OEM\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eYes\u003c\/strong\u003e – Genuine Coleman OEM replacement observation burner cap assembly.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eCompatible Brands\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eColeman\u003c\/li\u003e\n\u003cli\u003eYork\u003c\/li\u003e\n\u003cli\u003eLuxaire\u003c\/li\u003e\n\u003cli\u003eFraser-Johnston\u003c\/li\u003e\n\u003cli\u003eEvcon\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAlways verify compatibility using the furnace model and serial number.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eApplication\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eGas furnaces\u003c\/li\u003e\n\u003cli\u003eBurner compartment inspection ports\u003c\/li\u003e\n\u003cli\u003eObservation windows\u003c\/li\u003e\n\u003cli\u003eCombustion chamber access covers\u003c\/li\u003e\n\u003cli\u003eFurnace maintenance and service\u003c\/li\u003e\n\u003cli\u003eOEM replacement repairs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eRelated Components\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e7706A3171 Burner Observation Door Gasket\u003c\/li\u003e\n\u003cli\u003eBurner assemblies\u003c\/li\u003e\n\u003cli\u003eFlame sensors\u003c\/li\u003e\n\u003cli\u003eHot surface ignitors\u003c\/li\u003e\n\u003cli\u003eDraft inducer assemblies\u003c\/li\u003e\n\u003cli\u003eGas valves\u003c\/li\u003e\n\u003cli\u003eFurnace control boards\u003c\/li\u003e\n\u003cli\u003eObservation door hardware\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eTechnician Notes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eGenuine OEM burner observation cap assembly.\u003c\/li\u003e\n\u003cli\u003eIncludes fire glass viewing window.\u003c\/li\u003e\n\u003cli\u003eIncludes replacement gasket.\u003c\/li\u003e\n\u003cli\u003eAllows visual inspection of burner flame operation.\u003c\/li\u003e\n\u003cli\u003eMaintains burner compartment sealing when properly installed.\u003c\/li\u003e\n\u003cli\u003eReplace if glass is cracked, clouded, broken, or if gasket integrity is compromised.\u003c\/li\u003e\n\u003cli\u003eInspect surrounding burner compartment components during replacement.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eCommon Symptoms of Failure\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eCracked or broken fire glass\u003c\/li\u003e\n\u003cli\u003eMissing observation cap\u003c\/li\u003e\n\u003cli\u003eDamaged gasket seal\u003c\/li\u003e\n\u003cli\u003eAir leakage around burner compartment\u003c\/li\u003e\n\u003cli\u003eDiscolored or clouded viewing window\u003c\/li\u003e\n\u003cli\u003eHeat damage to cap assembly\u003c\/li\u003e\n\u003cli\u003eDifficulty viewing burner flame\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch2\u003eInstallation Tips\u003c\/h2\u003e\n\u003col\u003e\n\u003cli\u003eDisconnect power and gas supply before servicing.\u003c\/li\u003e\n\u003cli\u003eRemove the damaged observation cap assembly.\u003c\/li\u003e\n\u003cli\u003eClean gasket mating surfaces thoroughly.\u003c\/li\u003e\n\u003cli\u003eInstall the new gasket and observation cap.\u003c\/li\u003e\n\u003cli\u003eVerify proper seating and alignment.\u003c\/li\u003e\n\u003cli\u003eTighten hardware evenly to avoid glass stress.\u003c\/li\u003e\n\u003cli\u003eRestore power and gas supply.\u003c\/li\u003e\n\u003cli\u003eConfirm proper burner operation and seal integrity.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003chr\u003e\n\u003ch2\u003eRecommended Inspection Items\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eBurner assembly condition\u003c\/li\u003e\n\u003cli\u003eFlame sensor cleanliness\u003c\/li\u003e\n\u003cli\u003eIgnitor operation\u003c\/li\u003e\n\u003cli\u003eBurner compartment gaskets\u003c\/li\u003e\n\u003cli\u003eObservation door condition\u003c\/li\u003e\n\u003cli\u003eDraft inducer performance\u003c\/li\u003e\n\u003cli\u003eHeat exchanger condition\u003c\/li\u003e\n\u003cli\u003eGas valve operation\u003c\/li\u003e\n\u003cli\u003eFurnace venting system\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"HVAC Part Store","offers":[{"title":"Default Title","offer_id":46095352332354,"sku":null,"price":51.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1071\/8320\/files\/Screenshot2026-11-19192042.png?v=1795141258"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1071\/8320\/collections\/7000_Series_Coleman_Parts_JPEG_Page_18.jpg?v=1750302634","url":"https:\/\/hvacpartstoremarket.com\/collections\/7665-coleman-parts-breakdown.oembed","provider":"HVACpartstore","version":"1.0","type":"link"}